Comparison of the Effect of Various External Pressure on Blood During Rapid Infusion

Hyub Huh1 site in 1 country25 target enrollmentStarted: August 1, 2015Last updated:
Conditions
Interventions

Trial Snapshot

Phase
Not Applicable
Status
Completed
Sponsor
Enrollment
25
Locations
1
Primary Endpoint
Hemolysis and alteration of deformability of red blood cell caused by external pressure

Study Overview

Brief Summary

Rapid infusion of blood is needed occasionally for control massive bleeding. For rapid infusion, external pressure can be used. The investigators will study correlation between external pressure and hemolysis and deformability of red blood cell.

Detailed Description

Rapid infusion of blood is needed occasionally for control massive bleeding. For rapid infusion, external pressure can be used which cause hemolysis and alteration of red blood cell. The investigators will study correlation between variable external pressure and hemolysis and deformability of red blood cell. Differ from previous study, the investigator will use scanning electron microscope for observation red blood cell.

Study Design

Study Type
Interventional
Allocation
Randomized
Intervention Model
Parallel
Primary Purpose
Supportive Care
Masking
Single (Investigator)

Eligibility Criteria

Ages
20 Years to 50 Years (Adult)
Sex
All
Accepts Healthy Volunteers
Yes

Inclusion Criteria

  • •healthy volunteers, without any underlying disease.

Exclusion Criteria

  • •history of delivery, abortion in past 6 months.
  • •weight : male under 50kg, female under 45kg
  • •heart rate under 50 or over 100
  • •fever : over 37.5
  • •blood pressure : over 180/100

Arms & Interventions

5days

Active Comparator

5 days after blood sampling, various external pressure test will be done. Blood wil be stored in refrigerator(Celsius 4 degree) until study day. External pressure 0, 100, 150, 200, 250, 300mmHg will be applied to each blood sample.

Intervention: Auto PC(Acemedical, Goyang-si, Korea) - 0mmHg(control) (Device)

5days

Active Comparator

5 days after blood sampling, various external pressure test will be done. Blood wil be stored in refrigerator(Celsius 4 degree) until study day. External pressure 0, 100, 150, 200, 250, 300mmHg will be applied to each blood sample.

Intervention: Auto PC(Acemedical, Goyang-si, Korea) - 150mmHg (Device)

5days

Active Comparator

5 days after blood sampling, various external pressure test will be done. Blood wil be stored in refrigerator(Celsius 4 degree) until study day. External pressure 0, 100, 150, 200, 250, 300mmHg will be applied to each blood sample.

Intervention: Auto PC(Acemedical, Goyang-si, Korea) - 200mmHg (Device)

5days

Active Comparator

5 days after blood sampling, various external pressure test will be done. Blood wil be stored in refrigerator(Celsius 4 degree) until study day. External pressure 0, 100, 150, 200, 250, 300mmHg will be applied to each blood sample.

Intervention: Auto PC(Acemedical, Goyang-si, Korea) - 250mmHg (Device)

5days

Active Comparator

5 days after blood sampling, various external pressure test will be done. Blood wil be stored in refrigerator(Celsius 4 degree) until study day. External pressure 0, 100, 150, 200, 250, 300mmHg will be applied to each blood sample.

Intervention: Auto PC(Acemedical, Goyang-si, Korea) - 300mmHg (Device)

35days

Active Comparator

35 days after blood sampling, various external pressure test will be done. Blood wil be stored in refrigerator(Celsius 4 degree) until study day. External pressure 0, 100, 150, 200, 250, 300mmHg will be applied to each blood sample.

Intervention: Auto PC(Acemedical, Goyang-si, Korea) - 0mmHg(control) (Device)

35days

Active Comparator

35 days after blood sampling, various external pressure test will be done. Blood wil be stored in refrigerator(Celsius 4 degree) until study day. External pressure 0, 100, 150, 200, 250, 300mmHg will be applied to each blood sample.

Intervention: Auto PC(Acemedical, Goyang-si, Korea) - 150mmHg (Device)

35days

Active Comparator

35 days after blood sampling, various external pressure test will be done. Blood wil be stored in refrigerator(Celsius 4 degree) until study day. External pressure 0, 100, 150, 200, 250, 300mmHg will be applied to each blood sample.

Intervention: Auto PC(Acemedical, Goyang-si, Korea) - 200mmHg (Device)

35days

Active Comparator

35 days after blood sampling, various external pressure test will be done. Blood wil be stored in refrigerator(Celsius 4 degree) until study day. External pressure 0, 100, 150, 200, 250, 300mmHg will be applied to each blood sample.

Intervention: Auto PC(Acemedical, Goyang-si, Korea) - 250mmHg (Device)

35days

Active Comparator

35 days after blood sampling, various external pressure test will be done. Blood wil be stored in refrigerator(Celsius 4 degree) until study day. External pressure 0, 100, 150, 200, 250, 300mmHg will be applied to each blood sample.

Intervention: Auto PC(Acemedical, Goyang-si, Korea) - 300mmHg (Device)

Outcomes

Primary Outcomes

Hemolysis and alteration of deformability of red blood cell caused by external pressure

Time Frame: 1hour