Accuracy and Precision of Different Devices for the Monitoring of Pulsed Oxygen Saturation
- Conditions
- Arterial Pulsed Oxygen Saturation
- Registration Number
- NCT02832817
- Lead Sponsor
- University Hospital, Angers
- Brief Summary
Hypoxemia is a frequent situation in clinical practice, particularly in intensive care units or perioperative. The mortality and morbidity increase for cardiovascular reason, due to hypoxia has been reported several times. It is therefore important to detect hypoxemia very early and with accuracy. The objective is to correct the causes quickly and thus avoid or minimize complications.
In addition to the risks associated with hypoxemia, the monitoring of Arterial Oxygen Saturation also avoids the adverse effects associated with hyperoxia. Indeed oxygen leads to the formation of free radicals, which in physiological condition are regulated by antioxidant mechanisms. However, in anesthesiology, it is common to find pathological situations (acute respiratory distress syndrome, shock, prolonged inflammatory state) where these regulatory mechanisms are overwhelmed. Oxygen administration to supra-physiological concentrations leads to a formation of excessive free radicals, aggravating the existing injury (including lung).
Oxygen therapy is a fully-fledged treatment requiring monitoring of its effectiveness and tolerance. Currently, the standard method for assessing oxygenation is the arterial blood gas analysis with the Arterial Oxygen Saturation. Its cost and the need for an arterial blood sample do not allow regular monitoring. Clinical evaluation of hypoxia is completely unreliable. there is a third method : monitoring devices that measure Arterial Pulsed Oxygen Saturation, called "pulse oximeters." Pulse oximeters have become an integral and mandatory part of the standard monitoring. It is through the measurement of Arterial Pulsed Oxygen Saturation, supposed to reflect Arterial Oxygen Saturation, that clinicians guide their therapeutic attitudes to optimize oxygenation and improve the prognosis of patients. So pulse oximetry is a method considered reliable and especially non-invasive. It is less expensive and does not require blood sampling. These qualities explain why these devices are easily used in anesthesia, intensive care and in emergency situations.
However, several studies have demonstrated the inaccuracy of Arterial Pulsed Oxygen Saturation in frequent situations resuscitation (shock, sepsis, dark skin type). Thus, it is necessary to objectify the benefits and limitations of pulse oximetry to optimize their use, especially in these situations of high risk, where a discrepancy between the values measured by the pulse oximetry and measurement of arterial blood saturation with oxygen gas can be detrimental.
It exists several pulse oximetry devices, whose accuracy seems unequal, which necessitates a comparative study.
- Detailed Description
Not available
Recruitment & Eligibility
- Status
- UNKNOWN
- Sex
- All
- Target Recruitment
- 200
- Hospitalization in intensive care
- Over 18 years
- Continuous monitoring of oxygen saturation
- Susceptible oo have arterial blood gases and carrying an arterial catheter
- patient protected by the law
- no social security number
- carbon monoxide Intoxication
- High methemoglobinemia.
- Therapeutic limitation
Study & Design
- Study Type
- OBSERVATIONAL
- Study Design
- Not specified
- Primary Outcome Measures
Name Time Method Oxygen saturation by pulse oximetry monitoring accuracy at each arterial blood gas during ICU hospitalization (max 5 punctures from inclusion to ICU discharge - average of 1 week) determine the accuracy of oxygen saturation by pulse oximetry monitoring devices (SpO2) compared to the reference method, arterial oxygen saturation (SaO2) by blood gas on Co-Oximeter
- Secondary Outcome Measures
Name Time Method Number of participants for whom there will be mismatch between SpO2 (oxygen saturation by pulse oximetry) and SaO2 (arterial oxygen saturation) measures with medical adverse events (vasopressors, hypoxemia, acidosis, alkalosis) at each arterial blood gas during ICU hospitalization (max 5 punctures from inclusion to ICU discharge - average of 1 week) highlight groups with risks of discrepancy between SpO2 and Sa02, and describe with the following criteria : presence of vasopressors, mechanical ventilation, blood lactate value, hypoxemia, acidosis / alkalosis, skin hypoperfusion signs, skin phototype, temperature.
Trial Locations
- Locations (1)
Service de Réanimation Chirurgicale
🇫🇷Angers, France