临床试验/NCT02603874
NCT02603874Unknown不适用

The Development of a Vertebra Localizing Aid Medical Device

Target Tape0 个研究点目标入组 100 人开始时间: 2016年1月1日最近更新:
适应症

试验速览

阶段
不适用
发起方
入组人数
100
主要终点
Reduction in Fluoroscopy Exposure

研究概览

简要总结

The current method of incision localization in many surgical procedures requires a doctor to reference a medical image, such as an X-ray, to judge where on the body an incision should be made. However, the precise information of the scan is not shown on the patient's skin. Surgeons commonly use palpation to locate the point of incision. They may feel for the area directly or find landmarks under the skin and estimate the location from there. This can be challenging due to the difficulty of feeling and distinguishing each vertebra, especially for new surgeons, since palpation is a skill derived through experience.

If palpation proves ineffective, they may be forced to use fluoroscopy. By referencing the fluoroscopy image the surgeon moves a radiopaque marker, such as their surgical tool, closer to the area of interest. Fluoroscopy is time-consuming, and exposes medical personnel and the patient to radiation. Many fluoroscopic images may be required in a single procedure. The purpose of this study is to test the efficacy and benefits of a new medical device that will aid in radiological localization. The hypothesized outcome would be smaller incisions, faster localization and a reduction in fluoroscopy use.

By identifying the efficacy of this new medical device, "Target Tape", there is the potential outcome of making smaller incisions, faster localization, a reduction in fluoroscopy use and a reduced chance in surgical error and the associated costs.

Target Tape is a non invasive device that is in a grid format that is placed against the subject's skin. The grid pattern will then appear on the medical imaging scan. The medical practitioner can correlate device grid on the body to the medical scan image to make their incisions in more accurate locations.

详细描述

Consent must first be obtained from the prospective patient before Target Tape can be incorporated into the procedure. When a target procedure is scheduled to occur, the surgeon will first determine if Target Tape would be appropriate to use. The procedure will need to be able to integrate Target Tape into it using the Method of Use described above. The decision to then pursue the procedure will be under the discretion of the medical practitioner and consent from the patient. Depending on the procedure, the medical practitioner may need to communicate to the OR or the radiology department to integrate Target Tape into their protocol, since the practitioner making the incisions(s) may not always be the one applying it. Examples of spine procedures that may utilize Target Tape may be stabilization of fractures, tumor removals, fusions, discectomies and kyphoplasties. . Once the procedure is determined to be appropriate to accommodate Target Tape, the medical practitioner will approach the prospective patient and explain how the device will be utilized, the benefits and potential risks associated with it, and answer any questions the patient may have. A representative from Target Tape Inc may be on hand to aid with this process and may also observe said procedure to record the necessary information. The consent form will then be signed and Target Tape will then be utilized during the procedure.

The methodology of creating an outcome measure will occur over 2 stages with multiple steps in each stage:

Stage I: Proof of Concept

  1. Specify measurement goals
  2. Proof of Concept Testing
  3. Item generation
  4. Item reduction

Stage 2: Verification 5. Verification Testing 6. Reliability 7. Validity 8. Interpretability

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Parallel
主要目的
Supportive Care
盲法
None

入排标准

年龄范围
18 Years 至 99 Years(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Surgical spine procedures involving the use of medical imaging to determine the vertebra site (ex. fusions, tumor removals, fracture repairs, discectomies). The medical imaging scans may include planar X-rays, fluoroscopy, CT or MRI scans
  • Able and willing to consent

排除标准

  • Subjects who may have allergies to medical skin adhesives

结局指标

主要结局

Reduction in Fluoroscopy Exposure

时间窗: 6 months

Measuring the decreased amount of fluoroscopy radiation exposed to the medical staff and the patient

次要结局

未报告次要终点

研究者

发起方
Target Tape
申办方类型
Industry
责任方
Sponsor