跳至主要内容
临床试验/NCT06082752
NCT06082752已完成不适用

The Analysis of the Impact of 5-minute Massage Session on the Muscle Stiffness and Tone: a Randomised Control Trial

Wroclaw University of Health and Sport Sciences1 个研究点 分布在 1 个国家目标入组 80 人开始时间: 2023年10月20日最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
发起方
入组人数
80
试验地点
1
主要终点
Changes in maximal displacement of the medial and lateral gastrocnemius muscle

研究概览

简要总结

The study design was a randomised, controlled, parallel, two-arm trial. The subjects were randomly assigned to one of the study groups: the intervention group or the control group. The passive mechanical properties, i.e. the stiffness and tone of the medial and lateral gastrocnemius muscle (dominant leg) were assessed. Measures were taken twice: in the intervention group before and after the 5-minute massage session, and in the control group at the beginning of the meeting and again after 5 minutes.

详细描述

The purpose of this study was to determine whether a 5-minute massage, applied to healthy individuals, may change the passive mechanical muscle properties, which supposedly may prevent MSDs. The study is carried out on the medial and lateral gastrocnemius muscles because of their accessibility and crucial role in locomotion. MyotonPRO and TMG S2 devices were used to assess the stiffness and radial muscle displacement of the gastrocnemius muscle respectively.

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Parallel
主要目的
Other
盲法
None

入排标准

年龄范围
19 Years 至 24 Years(Adult)
性别
All
接受健康志愿者

入选标准

  • age between 19 and 24 years;
  • healthy individuals, with no lower limb pathology;
  • PA≥600 MET-min/week assessed by IPAQ questionnaire;
  • no medical contraindication of massage therapy;
  • body mass index 18,5 < BMI ≤ 25kg/m2
  • signing the informed consent.

排除标准

  • pregnant women;
  • individuals suffering from neurologic or orthopaedic problems;
  • lower limb surgical interventions;
  • musculoskeletal disorders
  • body mass index 18,5 > BMI ≥ 25kg/m2
  • the lack of informed consent.

结局指标

主要结局

Changes in maximal displacement of the medial and lateral gastrocnemius muscle

时间窗: 1) baseline, 2) immediately after the massage session

The maximal radial displacement is produced in the muscle belly after the electrical stimulation. Measuring device: TMG S2

Changes in delay time of the medial and lateral gastrocnemius muscle

时间窗: 1) baseline, 2) immediately after the massage session

Delay time is the time in which the muscle displacement increases to 10% after the electrical stimulation. Measuring device: TMG S2

Changes in dynamic stiffness of the medial and lateral gastrocnemius muscle

时间窗: 1) baseline, 2) immediately after the massage session

The dynamic stiffness corresponds to the soft tissues' capacity to resist external forces. Measuring device: MyotonPRO

Changes in logarithmic decrement of the medial and lateral gastrocnemius muscle

时间窗: 1) baseline, 2) immediately after the massage session

Logarithmic decrement is the dissipation of the tissue oscillation. Measuring device: MyotonPRO

Changes in mechanical stress relaxation time of the medial and lateral gastrocnemius muscle

时间窗: 1) baseline, 2) immediately after the massage session

Mechanical stress relaxation time is the time needed for the muscle to recover to its initial shape. Measuring device: MyotonPRO

Changes in sustain time of the medial and lateral gastrocnemius muscle

时间窗: 1) baseline, 2) immediately after the massage session

Sustain time is the time between 50% of maximum contraction to 50% of maximum relaxation of a muscle after the electrical stimulation. Measuring device: TMG S2

Changes in contraction time of the medial and lateral gastrocnemius muscle

时间窗: 1) baseline, 2) immediately after the massage session

Contraction time is the time between 10% and 90% of the muscle displacement after the electrical stimulation. Measuring device: TMG S2

Changes in relaxation time of the medial and lateral gastrocnemius muscle

时间窗: 1) baseline, 2) immediately after the massage session

Relaxation time is the time between 90% of maximum contraction and 50% of maximum relaxation of a muscle after the electrical stimulation. Measuring device: TMG S2

Changes in oscillation frequency of the medial and lateral gastrocnemius muscle

时间窗: 1) baseline, 2) immediately after the massage session

The oscillation frequency characterizes the tension of muscle tissue. Measuring device: MyotonPRO

Changes in creep of the medial and lateral gastrocnemius muscle

时间窗: 1) baseline, 2) immediately after the massage session

Creep is the ratio of relaxation (R) and time between the beginning of the mechanical impulse and the time point of maximal displacement Measuring device: MyotonPRO

次要结局

未报告次要终点

研究者

发起方
Wroclaw University of Health and Sport Sciences
申办方类型
Other
责任方
Principal Investigator
主要研究者

Krzysztof Kassolik, Phd

Principal Investigator

Wroclaw University of Health and Sport Sciences

研究点 (1)

Loading locations...

相似试验