跳至主要内容
临床试验/NCT07061015
NCT07061015已完成不适用

Evaluation Of Different Motor Driven Osseodensification Techniques Used For Implant Placement In Posteriorly Atrophied Mandible Of Osteoporotic Patients

Delta University for Science and Technology1 个研究点 分布在 1 个国家目标入组 18 人开始时间: 2023年3月1日最近更新:
适应症
干预措施

试验速览

阶段
不适用
状态
已完成
入组人数
18
试验地点
1
主要终点
peri implant bone density

研究概览

简要总结

different possible osseodensification techniques used to improve bone density around dental implants, using either ] osseodensifying drills, reverse drilling of conventional drills, and rotary expanders.

详细描述

the study include 3 groups with different implant drilling protocols; group 1 where osseodensifying burs are used, group 2 where conventional drills with reverse motion are used, group 3 where rotary expanders are used

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Parallel
主要目的
Other
盲法
None

入排标准

年龄范围
45 Years 至 60 Years(Adult)
性别
Female
接受健康志愿者
否

入选标准

  • •· Adult osteoporotic female patients confirmed by CBCT grey values ranging from 290 to 420 HU, with age range 45-60 years.
  • •Patients should be free from any other systemic diseases, according to ASA classifications (American society of Anesthesiologists).
  • •Patients of single or multiple missing teeth in the posterior mandible.
  • •A ridge width of 4mm and a height of > 8mm above the roof of Inferior Alveolar canal.
  • •No buccal concavities were present at the planned implant site

排除标准

  • •· Poor oral hygiene.
  • •Heavy smoker (more than 20 cigarettes /day),or alcoholic abusing patients.
  • •Radiation therapy to the head and neck region, or chemotherapy in the last 6 months prior to the implant placement.

研究组 & 干预措施

osseodensifying burs

Active Comparator

osseodensifying burs are used in reverse motion .

干预措施: osseodenification with osseodensifying burs (Procedure)

reverse drilling

Active Comparator

using conventional implant drills in reverse motion(anti clock wise)

干预措施: reverse drilling (Procedure)

rotary expanders

Active Comparator

using rotary expanders in clock wise motion

干预措施: rotary expanders (Procedure)

结局指标

主要结局

peri implant bone density

时间窗: 12 months

through ROI (region of interest) to measure Grey scale on Cone beam computed tomography CBCT

implant stability quotient

时间窗: 12 months

ISQ (implant stability quotient) using osstell device

alveolar ridge dimension changes

时间窗: 12 months

with cone beam computed tomography CBCT in coronal and sagittal cuts, in millimeters mm .

次要结局

未报告次要终点

研究者

申办方类型
Other
责任方
Sponsor

研究点 (1)

Loading locations...

相似试验