SpO2 Difference Between Fingers of the Hand During Sequential Desaturation and Step Resaturation
- Conditions
- SpO2HypoxiaPulse Oximetry
- Registration Number
- NCT05681637
- Lead Sponsor
- Czech Technical University in Prague
- Brief Summary
The aim of the project is to experimentally compare the fingers of the hand in terms of measured concentrations of peripheral blood oxygen saturation (SpO2) in healthy humans during gradual desaturation in the range of 60-100% SpO2 and simultaneously during a step change from the hypoxic phase to the recovery phase (return to physiological values).
- Detailed Description
The finger sensors of pulse oximeters are most often placed on the middle two fingers of the hand. Although there have been many studies looking at the accuracy of different pulse oximeters or comparing fingers in terms of SpO2. There is no study comparing fingers in terms of SpO2 under hypoxic condition with simultaneous randomization of finger probe placement. At the same time, there is no study that compares SpO2 changes between fingers during a step change in blood oxygen saturation. The data obtained could help to improve the reliability of monitoring physiological parameters with pulse oximeters.
Recruitment & Eligibility
- Status
- ENROLLING_BY_INVITATION
- Sex
- All
- Target Recruitment
- 40
- Passing the initial examination, which will determine the following data: finger circumference, heart rate, blood pressure and blood oxygen saturation
- post-traumatic conditions of the upper limbs affecting the perfusion of the fingers or injuries or skin diseases on the fingers.
- pneumothorax or a condition after cardiovascular surgery.
- anemia, bradycardia, hemoglobinopathy or other diseases of the cardiovascular system, pregnancy, diabetes, hypotension or hypertension.
Study & Design
- Study Type
- INTERVENTIONAL
- Study Design
- SINGLE_GROUP
- Primary Outcome Measures
Name Time Method Non-invasive SpO2 measurements will be performed continuously on all individual fingers of left hand of volunteers and then the measured values will be compared between each other. 1 hour The experiment can help determine if it depends on which finger the finger sensor will be placed to measure SpO2. Appropriate finger selection for SpO2 measurements could help to better interpret the measured values and possibly increase the success in diagnosing health events.
- Secondary Outcome Measures
Name Time Method Non-invasive Perfusion Index measurements will be performed continuously on all individual fingers of left hand of volunteers and then the measured values will be compared between each other. 1 hour The experiment can help determine if it depends on which finger the finger sensor will be placed to measure perfusion index. Measurement of PI is evaluated during for example surgeries.
Related Research Topics
Explore scientific publications, clinical data analysis, treatment approaches, and expert-compiled information related to the mechanisms and outcomes of this trial. Click any topic for comprehensive research insights.
Trial Locations
- Locations (1)
Czech Technical University in Prague
🇨🇿Kladno, Czechia
Czech Technical University in Prague🇨🇿Kladno, Czechia