跳至主要内容
临床试验/NCT01528670
NCT01528670撤回不适用

Monitoring of Patients Treated With Particle Therapy Using Positron-Emission-Tomography (PET): The MIRANDA Study.

University Hospital Heidelberg1 个研究点 分布在 1 个国家开始时间: 2019年5月最近更新:
适应症

试验速览

阶段
不适用
状态
撤回
试验地点
1
主要终点
TBA

研究概览

简要总结

The purpose of this clinical study is to investigate the clinical feasibility and effectiveness of off-line Positron-Emission-Tomography (PET) quality assurance for promoting the accuracy of proton and carbon ion beam therapy. One main clinical advantage of ion therapy over conventional radiation therapy is the excellent conformation of the delivered dose to the tumour volume while well sparing the surrounding healthy tissue. However, clinical exploitation of this potential to the maximum extent requires in-vivo validation of the actual treatment delivery and, in particular, of the ion beam range within the patient. Since the primary ions are completely stopped in the target volume as opposed to photon radiation, no conventional quality assurance techniques like transmission electronic portal imaging can be applied to monitor ion beam therapy. Hence, ion treatment planning currently relies on models and experimental data accurately validated in tissue-equivalent targets, but no direct verification of the actual treatment delivery and of the ion beam range within the patient is possible in standard clinical practice.

At present, PET offers the unique possibility to monitor the precision of ion irradiation in-vivo and non-invasively. The method is based on the detection of the b+-activity which is formed as a by-product of the irradiation, i.e. without administration of radio-tracers to the patient. A positive clinical impact of in-beam (i.e. during the irradiation) PET monitoring has been demonstrated for carbon ion therapy in the pilot project at GSI Darmstadt, Germany, and promising clinical data of post-radiation PET/CT imaging have been recently reported for passive proton beam delivery in USA and Japan. Therefore, a pilot clinical study is hereby proposed at the Heidelberg Ion Therapy Center in order to 1) assess the applicability of post-radiation PET imaging to scanned ion beam delivery, 2) identify the patient population which may benefit from it and 3) extract population-based information on the reliability of the beam range in different tumour locations for all the ion species clinically available at HIT.

The investigated patients are expected to benefit from this study, since in case of detected deviations between planned and actual treatment delivery a proper correction could be applied in the next irradiation fraction, assuring an overall better treatment than without any monitoring. Moreover, site-specific patient-population information on the ion range precision at HIT might enable improvement of the CT-range calibration curve as well as safe reduction of the treatment margins to promote enhanced treatment plan conformality for full clinical exploitation of the promises of ion beam therapy.

研究设计

研究类型
Observational
观察模型
Other
时间视角
Prospective

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • 未提供

排除标准

  • 未提供

结局指标

主要结局

TBA

时间窗: TBA

TBA

次要结局

未报告次要终点

研究者

申办方类型
Other
责任方
Principal Investigator
主要研究者

Juergen Debus

Prof. Dr. Dr. Jürgen Debus

University Hospital Heidelberg

研究点 (1)

Loading locations...

相似试验