Skip to main content
Clinical Trials/NCT05346458
NCT05346458CompletedNot Applicable

A Single Centre, Prospective, Feasibility Study of the iKOs™ Coronary Pressure and Flow Rapid-exchange Microcatheter and iKOr™ Console in Patients With Coronary Heart Disease Undergoing Coronary Physiology Investigations

Queen Mary University of London1 site in 1 country10 target enrollmentStarted: December 14, 2022Last updated:
Conditions
Interventions

Trial Snapshot

Phase
Not Applicable
Status
Completed
Enrollment
10
Locations
1
Primary Endpoint
To assess the effectiveness of the iKOr system in measuring temperature change (flow) in patients with coronary artery disease undergoing physiology investigations

Study Overview

Brief Summary

The purpose of this investigation is to see if the newly developed "iKOs™ microcatheter" can safely and accurately measure flow and pressure within the heart arteries of 10 patients undergoing angiogram and pressure wire tests.

Detailed Description

After being informed about the study and the potential risks and benefits, participants who provide written consent will be screened to make sure they fulfil the study entry requirements. Those who are assessed as eligible will undergo baseline assessments and preparation for their angiogram.

Once enrolled they will undergo coronary angiography at the start of their clinical procedure. The angiogram will be examined by the Investigator and a decision made if the target vessel is suitable for a pressure wire study and insertion of the investigational device. If the investigator confirms that the participant remains eligible and the study part can go ahead, the participant will proceed to undergo the investigation with the iKOs microcatheter.

The study assessments will be performed through the right radial artery (preference) under local anaesthesia. A sheath will be inserted and a pre-procedure blood sample taken for Troponin T level. A pressure study will then be performed, initially with a pressure wire before using the iKOs™ microcatheter. Both will be performed before and after hyperaemia. Following withdrawal of the iKOs™ microcatheter, a pressure wire assessment is then repeated after the microcatheter is withdrawn. The case will then proceed as clinically indicated. The whole procedure should take about 30-45 minutes. Post-procedure the participant will be managed according to standard clinical practice.

The participant will be discharged home, usually about 4 hours after the end of the procedure. A troponin blood test and ECG will be repeated before they are discharged.

Follow up telephone calls to assess for any complications of the procedure will be made within the first 7 days and again between 6 and 8 weeks after the procedure.

Study Design

Study Type
Interventional
Allocation
Na
Intervention Model
Single Group
Primary Purpose
Diagnostic
Masking
None

Eligibility Criteria

Ages
18 Years to — (Adult, Older Adult)
Sex
All
Accepts Healthy Volunteers
No

Inclusion Criteria

  • •Able and willing to give informed consent
  • •>18 years old
  • •Have a clinical diagnosis of coronary artery disease
  • •Undergoing further assessment of a coronary artery with a pressure wire study

Exclusion Criteria

  • •Previous coronary artery bypass grafting.
  • •Non/ST-elevation myocardial infarction as indication for angiography.
  • •Ongoing evidence of ischaemia at rest.
  • •Severe renal impairment (GFR <25).
  • •Severe anaemia (Hb <10).
  • •Heparin allergy.
  • •Atrial fibrillation.
  • •Contraindication to adenosine.
  • •Pregnant or lactating; or female of childbearing potential.
  • •Participation in other interventional studies.
  • •Additional exclusion criteria at Angiogram:
  • •Critical coronary artery stenosis in the vessel which is to be studied (>90%).
  • •Left main stem coronary disease causing a >50% stenosis.
  • •Triple vessel coronary disease.

Arms & Interventions

Intra coronary rapid-exchange iKOs microcatheter intervention

Experimental

Patients with coronary heart disease and undergoing coronary physiology investigations (pressure wire measurements) will have additional coronary pressure and flow measurements using the iKOs rapid-exchange microcatheter and iKOr console.

Intervention: Intra coronary rapid-exchange iKOs microcatheter intervention (Device)

Outcomes

Primary Outcomes

To assess the effectiveness of the iKOr system in measuring temperature change (flow) in patients with coronary artery disease undergoing physiology investigations

Time Frame: Measured immediately prior to adenosine administration (baseline), and during adenosine administration (hyperaemia).

A change in thermal transit time measured by the iKOr system

Secondary Outcomes

  • To assess the effect of the iKOs microcatheter on cardiac injury(Troponin T measurement at procedure start and 4 hrs post procedure)
  • To assess the safety of the iKOs microcatheter in patients undergoing angiography and pressure wire assessment(Measured at procedure, at 4 hrs post procedure, at 1 week post procedure and 8 weeks post procedure)
  • To assess the safety of the iKOs microcatheter procedure(Measured at procedure, 4 hrs post procedure, at 1 week post procedure and 8 weeks post procedure)
  • To assess the effect of the iKOs microcatheter on TIMI (Thrombolysis In Myocardial Infarction) flow(TIMI flow measured immediately prior to insertion of iKOs microcatheter and on removal of the iKOs microcatheter)

Investigators

Sponsor Class
Other
Responsible Party
Sponsor

Study Sites (1)

Loading locations...

Similar Trials