VOLT CE Mark Study
- Conditions
- Atrial ArrhythmiaAtrial FibrillationPersistent Atrial FibrillationParoxysmal Atrial Fibrillation
- Registration Number
- NCT06106594
- Lead Sponsor
- Abbott Medical Devices
- Brief Summary
This clinical investigation is intended to demonstrate safety and effectiveness of the Volt™ Pulsed Field Ablation (PFA) Catheter Sensor Enabled™, the Volt™ PFA Generator, Agilis™ NxT Steerable Introducer Dual-Reach™, and EnSite™ X EP System EnSite™ Pulsed Field Ablation Module (for simplicity of reference this device collection will hereafter be referred to as the Volt™ PFA system) for the treatment of symptomatic, recurrent, drug-refractory paroxysmal and persistent atrial fibrillation.
- Detailed Description
The main study is a pre-market, prospective, single-arm, non-randomized, multicenter clinical study to demonstrate safety and effectiveness for the treatment of symptomatic, recurrent, drug-refractory Paroxysmal Atrial Fibrillation (PAF) and Persistent Atrial Fibrillation (PersAF). The main study design includes a feasibility sub-study in which additional imaging assessments will be collected in a small cohort of subjects to confirm acute safety of the Volt PFA System in humans.
The enrollment extension will include up to an additional 100 subjects enrolled with market-released or investigational devices, depending on enrollment geography.
Recruitment & Eligibility
- Status
- ACTIVE_NOT_RECRUITING
- Sex
- All
- Target Recruitment
- 250
-
Documented symptomatic PAF or PersAF. Documentation requirements are as follows:
Paroxysmal:
- Physician's note indicating recurrent self-terminating AF with ≥ 2 episodes of PAF within the 6 months prior to enrollment AND
- One electrocardiographically documented PAF episodes within 12 months prior to enrollment.
Persistent: Continuous AF sustained beyond 7 days and less than 1 year that is documented by
-
Physician's note, AND either
-
24-hour Holter within 180-days prior to enrollment, showing continuous AF, OR
-
Two electrocardiograms (from any form of rhythm monitoring) showing continuous AF:
- That are taken at least 7 days apart but less than 12 months apart
- If electrograms are more than 12 months apart, there must be one or more Sinus Rhythm recordings in between or within 12 months prior to consent/enrollment
- The most recent electrocardiogram must be within 180 days of enrollment.
NOTE: Documented evidence of the AF episode must either be continuous AF on a 12-lead ECG or include at least 30 seconds of AF from another ECG device.
-
Plans to undergo a PVI catheter ablation procedure due to symptomatic PAF or PersAF and is refractory, intolerant, or contraindicated to at least one Class I-IV AAD medication
-
At least 18 years of age
-
Able and willing to comply with all trial requirements including pre-procedure, post- procedure, and follow-up testing and requirements
-
Informed of the nature of the trial, agreed to its provisions, and has provided written informed consent as approved by the Institutional Review Board/Ethics Committee (IRB/EC) of the respective clinical trial site.
- Previously diagnosed long-standing persistent atrial fibrillation (AF greater than 1 year in duration)
- Arrhythmia due to reversible causes including thyroid disorders, acute alcohol intoxication, electrolyte imbalance, severe untreated sleep apnea, and other major surgical procedures in the preceding 90 days
- Participant known to require ablation beyond PVI at the time of consent (Main study only)
- Known presence of cardiac thrombus
- Left atrial diameter ≥ 5.5 cm (anteroposterior diameter)
- Left ventricular ejection fraction < 35% as assessed with echocardiography within 180 days of index procedure
- New York Heart Association (NYHA) class III or IV heart failure
- Body mass index > 40 kg/m2
- Pregnant, nursing, or planning to become pregnant during the clinical investigation follow-up period
- Patients who have had a ventriculotomy or atriotomy within the preceding 28 days of procedure,
- Myocardial infarction (MI), acute coronary syndrome, percutaneous coronary intervention (PCI), or valve or coronary bypass grafting surgery within preceding 90 days
- Unstable angina
- Stroke or TIA (transient ischemic attack) within the last 90 days
- Heart disease in which corrective surgery is anticipated within 180 days after procedure
- History of blood clotting or bleeding abnormalities including thrombocytosis, thrombocytopenia, bleeding diathesis, or suspected anti-coagulant sate
- Contraindication to long term anti-thromboembolic therapy
- Patient unable to receive heparin or an acceptable alternative to achieve adequate anticoagulation
- Known sensitivity to contrast media (if needed during the procedure) that cannot be controlled with pre-medication
- Previous left atrial surgical or catheter ablation procedure (including LAA closure device)
- Presence of any condition that precludes appropriate vascular access
- Severe mitral regurgitation (regurgitant volume ≥ 60 mL/beat, regurgitant fraction ≥ 50%, and/or effective regurgitant orifice area ≥ 0.40cm2).
- Previous tricuspid or mitral valve replacement or repair
- Patients with prosthetic valves
- Patients with a myxoma
- Patients with an interatrial baffle or patch as the transseptal puncture could persist and produce an iatrogenic atrial shunt
- Stent, constriction, or stenosis in a pulmonary vein
- Rheumatic heart disease
- Hypertrophic cardiomyopathy
- Diagnosed with amyloidosis or atrial amyloidosis
- Active systemic infection
- Renal failure requiring dialysis
- Severe pulmonary disease (e.g., restrictive pulmonary disease, constrictive or chronic obstructive pulmonary disease) or any other disease or malfunction of the lungs or respiratory system that produces severe chronic symptoms
- Presence of an implantable therapeutic cardiac device including permanent pacemaker, biventricular pacemaker, or any type of implantable cardiac defibrillator (with or without biventricular pacing function) or planned implant of such a device for any time during the follow-up period. Presence of an implantable loop recorder is acceptable as long as it is removed prior to insertion of the investigational device.
- Presence of an implanted LAA closure device or plans to have an LAA closure device implanted during the follow-up period
- Patient is currently participating in another clinical trial or has participated in a clinical trial within 30 days prior to screening that may interfere with this clinical trial without pre-approval from this study Sponsor
- Unlikely to survive the protocol follow up period of 12 months
- Presence of other medical, anatomic, comorbid, social, or psychological conditions that, in the investigator's opinion, could limit the subject's ability to participate in the clinical investigation or to comply with follow-up requirements, or impact the scientific soundness of the clinical investigation results.
- Individuals without legal authority
- Individuals unable to read or write
Study & Design
- Study Type
- INTERVENTIONAL
- Study Design
- SEQUENTIAL
- Primary Outcome Measures
Name Time Method Rate of subjects experiencing a device and/or procedure-related serious adverse event with onset within 7-days of any ablation procedure that uses the Volt PFA System. 7-days Serious adverse events are defined as:
* Atrio-esophageal fistula
* Cardiac tamponade/perforation
* Death
* Heart block
* Myocardial infarction
* Pericarditis
* Phrenic nerve injury resulting in permanent diaphragmatic paralysis
* Pulmonary edema
* Pulmonary vein stenosis
* Stroke/cerebrovascular accident
* Thromboembolism
* Transient ischemic attack
* Vagal nerve injury/gastroparesis
* Major vascular access complications / major bleeding events
* Device and/or procedure related cardiovascular and/or pulmonary adverse event that prolongs hospitalization for more than 48 hours (excluding hospitalization solely for arrhythmia recurrence or non-urgent cardioversion)Acute procedural effectiveness summarized as the rate of pulmonary veins treated with the Volt PFA system that are isolated at the end of the index ablation procedure. During procedure Acute procedural failure for each pulmonary vein is defined as any of the following:
1. Inability to isolate a pulmonary vein at the end of the index ablation procedure. Isolation will be assessed via confirmation of electrical isolation in each ablated pulmonary vein after a minimum waiting period of 20 minutes via entrance block at a minimum. Touch-up ablation to achieve isolation will be allowed for any pulmonary vein reconnection detected during the index procedure with the investigational catheter (to the maximum delivery allowed per vein) and will not be considered a failure.
2. Any use of a non-study ablation device for pulmonary vein isolation.Long-term 6-month effectiveness summarized as the rate of freedom from documented AF/AFL/AT episodes of >30 seconds duration after the index ablation procedure through 6 months of follow-up. 6 months The situations in which subjects will be considered long-term effectiveness endpoint failures:
* Acute procedural failure
* Any use of a non-study ablation device for pulmonary vein isolation or to deliver ablation lesions in the left atrium during the index procedure or during the first repeat procedure.
* If documented AF/AFL/AT recurrence occurs at any time after the blanking period
* If subject requires a repeat procedure for the treatment of AF, non-CTI-dependent AFL, or AT after the blanking period or a second repeat AF ablation procedure at any time after the index ablation procedure.
* Any use of a new class I or III AAD for AF after the blanking period.
* Any use of a class I or III AAD for AF at a dose higher than the historical maximum dose for the subject after the blanking period.
* If the subject requires a cardioversion for the treatment of AF/AFL/AT after the blanking period
* Surgical treatment of AF/AFL/AT post index procedure.
- Secondary Outcome Measures
Name Time Method
Trial Locations
- Locations (11)
UMC Utrecht
🇳🇱Utrecht, Netherlands
Hospital Universitari i Politècnic La Fe
🇪🇸Valencia, Spain
The Prince Hospital
🇦🇺Chermside, QUEENSL, Australia
Royal Adelaide Hospital
🇦🇺Adelaide, SAUSTRL, Australia
Monash Health
🇦🇺Clayton, Victoria, Australia
Royal Melbourne Hospital - City Campus
🇦🇺Parkville, Victoria, Australia
A. ö. Krankenhaus der Elisabethinen Linz
🇦🇹Linz, Upr Aus, Austria
AZ Sint Jan
🇧🇪Bruges, Wflndrs, Belgium
UZ Brussel
🇧🇪Brussel, Belgium
Nemocnice Na Homolce
🇨🇿Prague, CBOHMIA, Czechia
Universitätsklinikum Schleswig-Holstein - Campus Lübeck
🇩🇪Lübeck, Schlesw, Germany