跳至主要内容
临床试验/NCT02271126
NCT02271126已完成1 期

Prospective Randomized Study Of Anticoagulation Monitoring With Thromboelastography Versus aPTT During Extracorporeal Membrane Oxygenation In Adults

Policlinico Hospital1 个研究点 分布在 1 个国家目标入组 42 人开始时间: 2014年9月2日最近更新:
适应症
干预措施
相关药物

试验速览

阶段
1 期
状态
已完成
发起方
入组人数
42
试验地点
1
主要终点
Feasibility

研究概览

简要总结

The best anticoagulation strategy during Extracorporeal Membrane Oxygenation (ECMO) is unknown. Actual recommendations suggest to use unfractionated heparin infusion and monitor the effect with either activated Partial Thromboplastin Time (aPTT) or Activated Clotting Time (ACT). Since hemorrhage is still the major adverse effect of ECMO with impact on mortality and morbidity, the investigators raised a question whether an alternative monitoring technique namely Thromboelastography (TEG) could allow a more accurate management of anticoagulation in this setting. To test this hypothesis the investigators designed a pilot study to test safety and feasibility of an anticoagulation monitoring algorithm based on TEG versus aPTT.

详细描述

Extracorporeal membrane oxygenation (ECMO) is frequently used as a supportive tool in the settings of acute severe respiratory and/or circulatory failure. The presence of the extracorporeal circuit and oxygenator bring along the need to anticoagulate the patients in order to prevent activation of the coagulation cascade that can lead to thrombosis of the artificial surfaces and losses of coagulation factors, fibrinogen and platelets. Despite tight monitoring with different anticoagulation essays bleeding remain the main threat for the patients on ECMO, leaving thrombosis as an anecdotic event.

In our institution, anticoagulation during ECMO is monitored mainly with aPTT ratio in a range of 1.5 to 2 (patient to normal). Recently, the investigators started to match Thromboelastography (TEG) assays to activated Partial Thromboplastin Time (aPTT) and Activated Clotting Time (ACT) routine measurements during ECMO. Data from a preliminary analysis of thirty-two patients show that in nearly half of TEG assays, the R (reaction time) parameter which is sensitive to inhibition of fibrin formation by heparin, was consistently prolonged despite aPTT and ACT were in the normal range. In the same patients the investigators registered high rate of bleeding (nearly 40% of patients suffered from clinically significant bleeding, i.e. bleeding that required heparin dose reduction, blood transfusions or interruption of the extracorporeal support). These findings suggests the possibility that the actual target of aPTT ratio might be overrated.

The purpose of this study is to test safety and feasibility of standardized protocol based on TEG versus current practice (aPTT) to manage anticoagulation during ECMO.

40 consecutive adults patients undergoing ECMO will be randomized in either the TEG-driven anticoagulation group or the aPTT-driven group. Written informed consent will be obtained according to national legislation.

In both groups, when the patient is connected to ECMO, an heparin bolus of 50-70 UI/kg (depending on baseline aPTT value) will be administered followed by a continuous infusion of 18 UI/kg/h started; for the first 12 hours thereafter proper anticoagulation level will be monitored with Activated Clotting Time (ACT, therapeutic range 180-210 seconds, performed every 1 or 2 hours according to the standardized protocol). From the thirteenth hour onwards each group will follow either aPTT monitoring or TEG according to randomization. Every morning in both groups aPTT, TEG, Antithrombin and anti-Factor Xa activity will be assessed.

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Parallel
主要目的
Prevention
盲法
None

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • All patients that initiate ECMO support for acute respiratory failure at our centre or by our equipe at another centre will be screened for eligibility.

排除标准

  • Patients under the age of 18, with proven Heparin-induced Thrombocytopenia or with a platelets count of less than 30.000/mm3 will be excluded from the study.

研究组 & 干预措施

TEG

Experimental

TEG-driven anticoagulation group: Anticoagulation will be monitored by TEG. Target will be a range of R parameter at Kaolin activated-TEG (R K-TEG) is 16 - 24 seconds; frequency of TEG assays may vary from a minimum of 3 times per day to a maximum of 6 depending on the standardized protocol. When TEG value falls well below the desired range an heparin bolus will be administered, when is too high infusion will be stopped for either 30 or 60 minutes.

干预措施: TEG monitoring (Device)

TEG

Experimental

TEG-driven anticoagulation group: Anticoagulation will be monitored by TEG. Target will be a range of R parameter at Kaolin activated-TEG (R K-TEG) is 16 - 24 seconds; frequency of TEG assays may vary from a minimum of 3 times per day to a maximum of 6 depending on the standardized protocol. When TEG value falls well below the desired range an heparin bolus will be administered, when is too high infusion will be stopped for either 30 or 60 minutes.

干预措施: Heparin (Drug)

APTT

Active Comparator

APTT-driven anticoagulation group: anticoagulation will be monitored by aPTT. aPTT ratio target is 1.5 - 2.0 as for actual clinical practice; frequency of aPTT measurements may vary from a minimum of 3 times per day to a maximum of 6 depending on the standardized protocol. When aPTT value falls well below the desired range an heparin bolus will be administered. When too high, infusion will be stopped for either 30 or 60 minutes.

干预措施: APTT monitoring (Device)

APTT

Active Comparator

APTT-driven anticoagulation group: anticoagulation will be monitored by aPTT. aPTT ratio target is 1.5 - 2.0 as for actual clinical practice; frequency of aPTT measurements may vary from a minimum of 3 times per day to a maximum of 6 depending on the standardized protocol. When aPTT value falls well below the desired range an heparin bolus will be administered. When too high, infusion will be stopped for either 30 or 60 minutes.

干预措施: Heparin (Drug)

结局指标

主要结局

Feasibility

时间窗: Two years

Heparin dose fluctuations and numbers of violation from the standardized protocol will be registered to assess feasibility.

Safety

时间窗: Two years

Safety will be addressed by monitoring the need of blood components, number of serious haemorrhagic events, thrombotic events and numbers of circuit replacement (due to circuit "activation" and characterized by a definite score that will be assessed daily).

次要结局

未报告次要终点

研究者

发起方
Policlinico Hospital
申办方类型
Other
责任方
Principal Investigator
主要研究者

Mauro Panigada, MD

MD

Policlinico Hospital

研究点 (1)

Loading locations...

相似试验