Skip to main content
Clinical Trials/NCT05386849
NCT05386849CompletedNot Applicable

Demonstration of an Artificial Intelligence Based Closed Loop Glucose Control System as a Therapeutic Modality in Type 2 Diabetic Patients

Ideal Medical Technologies2 sites in 1 country2 target enrollmentStarted: May 9, 2022Last updated:
Conditions

Trial Snapshot

Phase
Not Applicable
Status
Completed
Sponsor
Enrollment
2
Locations
2
Primary Endpoint
Primary Safety Outcome

Study Overview

Brief Summary

This is a proof of concept safety study of an artificial intelligence based closed loop glucose control system designed for use in the intensive care unit setting.

The type 2 diabetic subjects in this study will have their glucose controlled to a range of 100-140 mg/dL by a novel artificial intelligence based closed loop glucose control system for a period of 24 hours. The subjects will consume three standardized meals during the 24 hour study period.

Detailed Description

Tight glucose control in the intensive care unit (ICU) setting is difficult to achieve. The investigators hypothesize that a closed loop glucose control system based on artificial intelligence (AI) will improve upon the glucose control currently achieved by the current open loop manual methods, and that this improved glucose control may improve the outcomes of critically ill patients, including those with COVID-19.

This Earl Feasibility Study will test the ability of a prototype artificial intelligence based closed loop glucose control system named FUSION, to provide safe and effective glucose control in subjects with type 2 diabetes in a clinical research center (CRC) setting. Subjects with type 2 diabetes have been chosen as they are insulin resistant, which makes their insulin resistance profile similar to that of ICU patients. As this is the first in human study of a new medical device, the controlled environment of the CRC is preferable to the less controlled environment of an ICU setting.

The prototype FUSION system to be used in this study will consist to two Dexcom G6 continuous glucose monitors (CGM), the AI-based glucose control software run on an all-in-one medical computer, and two syringe pumps. The prototype system is housed on a medical cart. Based on the average glucose value of the two Dexcom G6 CGM's, and the rules of the FUSION systems AI-based glucose control software, the FUSION system will make rate adjustments every 5-10 minutes to the intravenous infusion rates of short acting insulin (NovoLog) and dextrose (D10NS) under its control, in an attempt to keep the subjects glucose in the range of 100-140 mg/dL. The FUSION system only requires entry of the subjects study identification number and weight in kilograms to initiate the system.

For safety reasons, the subjects will have their blood glucose independently measured every 10-60 minutes on a YSI 2900 glucose analyzer and the point of care Nova StatStrip system, throughout the 24 hour study period.

The study has halting criteria to avoid recurrent instances of severe hypoglycemia (< 54 mg/dL).

Study Design

Study Type
Interventional
Allocation
Na
Intervention Model
Single Group
Primary Purpose
Device Feasibility
Masking
None

Eligibility Criteria

Ages
18 Years to 70 Years (Adult, Older Adult)
Sex
All
Accepts Healthy Volunteers
No

Inclusion Criteria

  • Are 18-70 years of age, inclusive.
  • Can understand and sign an informed consent, communicate with the investigator, and understand and comply with the protocol requirements.
  • Have had a diagnosis of type 2 diabetes for a period of at least 3 months.
  • Use insulin injections at home for glucose control.
  • Have a hemoglobin A1c (HbA1c) in the range of 7.0 - 10.0%.
  • Have a hemoglobin in the normal range for sex:
  • Females: 12-15.5 grams/dL.
  • Males: 13.5-17.5 grams/dl.
  • Have adequate venous access sites in upper extremities.
  • Body weight between 40 - 150 kg.

Exclusion Criteria

  • Have participated in an interventional medical, surgical, or pharmaceutical study within 30 days of screening.
  • Have a known hypersensitivity to any of the components of study treatment.
  • Have skin disease/injury at Dexcom G6 CGM insertion site(s) that would prevent insertion of the CGM.
  • Currently abuses drugs or alcohol or has a history of abuse that in the investigator's opinion would cause the individual to be noncompliant.
  • Have a medical condition that in the opinion of the investigator could affect study participation and/or personal well-being.
  • Have a clinically significant history or presence of any of the following conditions:
  • Hepatic failure or has alanine aminotransferase (ALT) greater than 3 times the upper limit of normal.
  • Has an estimated GFR <30 ml/min/1.73 m2 or End Stage Kidney Disease on renal replacement therapy.
  • Have congestive heart failure greater than class 1 on the NYHA classification system.
  • Have a history of seizures.
  • Have a history of cerebrovascular accident.
  • Have a history of ischemic heart disease.
  • For female subjects of potential childbearing age (age 18 to 55) they will be excluded if:
  • Refuse to agree to a pregnancy test at the time of enrollment.
  • Have a positive urine pregnancy test at the time of enrollment.
  • Have a positive COVID-19 test within 14 days of visit
  • Have any COVID-19 related symptoms in the 14-day period prior to visit
  • Have a known unprotected COVID-19 exposure in the 14-day period prior to visit 3.

Outcomes

Primary Outcomes

Primary Safety Outcome

Time Frame: From beginning of use of the FUSION system to end of use of the FUSION system, which will be a period of time of up to 24 hours

The primary safety outcome will be the percent of all glucose values that are within the glucose range of less than 70 mg/dL.

Primary Efficacy Outcome

Time Frame: From beginning of use of the FUSION system to end of use of the FUSION system, which will be a period of time of up to 24 hours

The primary efficacy outcome will be the percent of all glucose values that are within the glucose range of 70-180 mg/dL.

Secondary Outcomes

  • Severe hypoglycemia(From beginning of use of the FUSION system to end of use of the FUSION system, which will be a period of time of up to 24 hours)
  • Glucose dispersion(From beginning of use of the FUSION system to end of use of the FUSION system, which will be a period of time of up to 24 hours)
  • Time in desired control range(From beginning of use of the FUSION system to end of use of the FUSION system, which will be a period of time of up to 24 hours)
  • Hyperglycemia(From beginning of use of the FUSION system to end of use of the FUSION system, which will be a period of time of up to 24 hours)

Investigators

Sponsor
Ideal Medical Technologies
Sponsor Class
Industry
Responsible Party
Sponsor

Study Sites (2)

Loading locations...

Similar Trials