Reliability of Non-invasive Carbon Dioxide Monitoring During Conscious Sedation for Adult Endoscopic Retrograde Cholangiopancreatography Patients
试验速览
- 阶段
- 不适用
- 入组人数
- 150
- 试验地点
- 2
- 主要终点
- mparison between CO2 measurement from non-invasive method (Dual guard) during conscious sedation for ERCP and invasive method (arterial blood gases).
研究概览
简要总结
CO2 monitoring through non-invasive methods to provide an early warning of hypoventilation during procedural sedation.
详细描述
Many patients become hypoxic during endoscopic retrograde cholangiopancreatography (ERCP). Following induced sedation, hypoxia or hypercapnia may follow . Monitoring the CO2 level during respiration (capnography) is non-invasive, easy to do, relatively inexpensive, and has been studied extensively . End-tidal carbon dioxide is the level of CO2 released at the end of an exhaled breath . Capnography provides information about ventilation, perfusion and metabolism . Capnography devices are configured as either side stream or mainstream. Side stream devices can monitor both intubated and non-intubated patients, while mainstream devices are most often limited to intubated patients .
The Dual guard (made in China) sets a standard in endoscopic practices; it incorporates an endoscopy bite block with oxygen delivery and CO2 monitoring for use in upper endoscopy procedures through to recovery . It improves patient safety and meets current guidelines for consciously sedated patients. The Comfort Rest Bite Block fits securely in the mouth, protecting both endoscope and patients' teeth. Simultaneous oral and nasal O2 delivery and CO2 sampling for patients undergoing upper GI endoscopy, in either a lateral or supine position. Arterial blood gas test results show the patient's acid-base balance, which is measured by the hydrogen ion concentration present in the blood, its oxygen saturation, partial pressure of oxygen (PaO2), partial pressure of carbon dioxide (PaCO2), concentration of bicarbonate (HCO3), base excess and base deficit . Itcan provide information about a surgical patient's physiological state, oxygenation, ventilation and indicate the primary source of a disturbance (ie, respiratory or metabolic) in homeostasis .
研究设计
- 研究类型
- Observational
- 观察模型
- Other
- 时间视角
- Prospective
入排标准
- 年龄范围
- 20 Years 至 50 Years(Adult)
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •Adult patients aged 20-50 years.
- •Males or females.
- •Elective Endoscopic Retrograde Cholangiopancreatography Patients
排除标准
- •Patient with abnormal renal function test.
- •Patient with history of chronic chest disease like asthma or Chronic obstructed pulmonary diseases.
- •Patients with a history of systemic illness like hypertension and diabetes.
- •Cardiac patients.
结局指标
主要结局
mparison between CO2 measurement from non-invasive method (Dual guard) during conscious sedation for ERCP and invasive method (arterial blood gases).
时间窗: october 2020
mparison between CO2 measurement from non-invasive method (Dual guard) during conscious sedation for ERCP and invasive method (arterial blood gases).
次要结局
未报告次要终点
研究者
Samar Fouad Yones
Resident of anesthesia and intensive care
Assiut University