Measurement of the Total Lung Volume Using Optimized Single-breath Helium Dilution Method in Patients With Obstructive Lung Disease
试验速览
- 阶段
- 不适用
- 状态
- 已完成
- 发起方
- 入组人数
- 628
- 试验地点
- 1
- 主要终点
- Establishment of the TLC-SBHD correction equation
研究概览
简要总结
Whole-body plethysmography (WBP) is the gold standard for measuring lung volume, but its clinical application is limited because it requires expensive equipment and is complicated to use. Studies have shown that the single-breath helium dilution (SBHD) method, which is commonly used in clinical practice, significantly underestimates lung volume in patients with obstructive lung disease (OLD). Therefore, by comparing the differences in lung volume measured by the SBHD method and WBP in patients with different severities of obstructive lung disease, we aim to establish a correction equation for the SBHD method to determine the total lung volume in obstructive lung disease patients.
研究设计
- 研究类型
- Observational
- 观察模型
- Cohort
- 时间视角
- Retrospective
入排标准
- 年龄范围
- 18 Years 至 80 Years(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •(1) age 18-80 years and (2) in line with the ATS/ERS definition of obstructive lung disease.
排除标准
- •(1) contraindications for spirometry, pulmonary diffusion function test, and WBP and (2) history of lung surgery and recent history of chest trauma.
结局指标
主要结局
Establishment of the TLC-SBHD correction equation
时间窗: 2 year
TLC-adjusted SBHD (L) = -0.669 + 0.756 × TLC-SBHD (L) - 0.047 × FEV1/FVC + 0.039 × height (cm) - 0.009 × weight (kg) (r2 = 0.753 and adjusted r2 = 0.751)
次要结局