跳至主要内容
临床试验/NCT03891082
NCT03891082Unknown不适用

A Comparative Study Between Bakri Balloon and B Lynch Suture Used to Control Primary Postpartum Hemorrhage After Cesarean Section

Cairo University0 个研究点目标入组 100 人开始时间: 2019年3月最近更新:
适应症
干预措施

试验速览

阶段
不适用
入组人数
100
主要终点
Estimation of blood loss:

研究概览

简要总结

Hundred (100) patients with primary postpartum hemorrhage during caesarean section due to atonic uterus will be recruited for this study.and randomized to either B lynch or Bakeri Ballon

B-Lynch:

A 70 mm round bodied hand needle on which a No. 2 absorbable suture is mounted is used to puncture the uterus 3 cm from the right lower edge of the uterine incision and 3 cm from the right lateral border. The mounted No. 2 absorbable suture is threaded through the uterine cavity to emerge at the upper incision margin 3 cm above and approximately 4 cm from the lateral border (because the uterus widens from below upwards). The absorbable suture now visible is passed over to compress the uterine fundus approximately 34 cm from the right cornual border. The absorbable suture is fed posteriorly and vertically to enter the posterior wall of the uterine cavity at the same level as the upper anterior entry point. The absorbable suture is pulled under moderate tension assisted by manual compression exerted by the first assistant. The length of the absorbable suture is passed back posteriorly through the same surface marking as for the right side, the suture lying horizontally. The absorbable suture is fed through posteriorly and vertically over the fundus to lie anteriorly and Research Template 7 Final Version: 1/6/2018 vertically compressing the fundus on the left side as occurred on the right. The needle is passed in the same fashion on the left side through the uterine cavity and out approximately 3 cm anteriorly and below the lower incision margin on the left side. The two lengths of absorbable suture are pulled taught assisted by bi-manual compression to minimize trauma and to achieve or aid compression. During such compression the vagina is checked that the bleeding is controlled. As good hemostasis is secured and whilst the uterus is compressed by an experienced assistant the principal surgeon throws a knot (double throw) followed by two or three further throws to secure tension. The lower transverse uterine incision is now closed in the normal way, in two layers, with or without closure of the lower uterine segment peritoneum. BALLOON INSERTION Insert the balloon portion of the catheter in the uterus; making certain that the entire balloon is inserted past the cervical canal and internal ostium. NOTE: Avoid excessive force when inserting the balloon into the uterus. Place a Foley catheter in patient bladder to collect and monitor urine output. To ensure maintenance of correct placement and maximize tamponade effect, the vaginal canal may be packed with iodine or antibiotic soaked vaginal gauze at this time.

详细描述

Hundred (100) patients with primary postpartum hemorrhage during caesarean section due to atonic uterus will be recruited for this study.and randomized to either B lynch or Bakeri Ballon

B-Lynch:

A 70 mm round bodied hand needle on which a No. 2 absorbable suture is mounted is used to puncture the uterus 3 cm from the right lower edge of the uterine incision and 3 cm from the right lateral border. The mounted No. 2 absorbable suture is threaded through the uterine cavity to emerge at the upper incision margin 3 cm above and approximately 4 cm from the lateral border (because the uterus widens from below upwards). The absorbable suture now visible is passed over to compress the uterine fundus approximately 34 cm from the right cornual border. The absorbable suture is fed posteriorly and vertically to enter the posterior wall of the uterine cavity at the same level as the upper anterior entry point. The absorbable suture is pulled under moderate tension assisted by manual compression exerted by the first assistant. The length of the absorbable suture is passed back posteriorly through the same surface marking as for the right side, the suture lying horizontally. The absorbable suture is fed through posteriorly and vertically over the fundus to lie anteriorly and Research Template 7 Final Version: 1/6/2018 vertically compressing the fundus on the left side as occurred on the right. The needle is passed in the same fashion on the left side through the uterine cavity and out approximately 3 cm anteriorly and below the lower incision margin on the left side. The two lengths of absorbable suture are pulled taught assisted by bi-manual compression to minimize trauma and to achieve or aid compression. During such compression the vagina is checked that the bleeding is controlled. As good hemostasis is secured and whilst the uterus is compressed by an experienced assistant the principal surgeon throws a knot (double throw) followed by two or three further throws to secure tension. The lower transverse uterine incision is now closed in the normal way, in two layers, with or without closure of the lower uterine segment peritoneum. BALLOON INSERTION Insert the balloon portion of the catheter in the uterus; making certain that the entire balloon is inserted past the cervical canal and internal ostium. NOTE: Avoid excessive force when inserting the balloon into the uterus. Place a Foley catheter in patient bladder to collect and monitor urine output. To ensure maintenance of correct placement and maximize tamponade effect, the vaginal canal may be packed with iodine or antibiotic soaked vaginal gauze at this time.

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Parallel
主要目的
Treatment
盲法
None

入排标准

年龄范围
18 Years 至 40 Years(Adult)
性别
Female
接受健康志愿者

入选标准

  • Patient undergoing caesarean sections landing up in atonic PPH during LSCS with failure of medical line of management:
  • Full term pregnancy
  • Didn't complete her family
  • Elective caesarian section

排除标准

  • 1.) PPH after vaginal delivery 2.) Secondary PPH 3.) PPH due to causes other than atonicity 4.) Antepartum hemorrhage cases 5.) Patients with bleeding tendency 6.) If any complication occurred during caesarian section (e.g. bladder injury, DIC)

研究组 & 干预措施

B-Lynch

Active Comparator

A 70 mm round bodied hand needle on which a No. 2 absorbable suture is mounted is used to puncture the uterus 3 cm from the right lower edge of the uterine incision and 3 cm from the right lateral border. The mounted No. 2 absorbable suture is threaded through the uterine cavity to emerge at the upper incision margin 3 cm above and approximately 4 cm from the lateral border.The absorbable suture is fed posteriorly and vertically to enter the posterior wall of the uterine cavity at the same level as the upper anterior entry point.

干预措施: B-Lynch (Procedure)

Bakri balloon

Active Comparator

Insert the balloon portion of the catheter in the uterus; making certain that the entire balloon is inserted past the cervical canal and internal ostium.

干预措施: BALLOON INSERTION (Procedure)

结局指标

主要结局

Estimation of blood loss:

时间窗: during the operation

number of saturated pads + amount in suction container (if used) + visualization by the operating team.

次要结局

未报告次要终点

研究者

申办方类型
Other
责任方
Principal Investigator
主要研究者

Ahmed M Maged, MD

Principal investigator

Cairo University

相似试验

A Comparative Study Between Bakri Balloon and B... | 临床试验