Effects of Automated Adjustment of the Inspired Oxygen in Reducing the Risk of Regional Cerebral (rSO2) Hypo-oxygenation in Preterm Infants on Non Invasive or Invasive Respiratory Support
试验速览
- 阶段
- 不适用
- 入组人数
- 60
- 试验地点
- 2
- 主要终点
- the burden of hypoxemia on regional cerebral saturation (rStO2) calculated as area under curve (AUC-% second) below the individual median rStO2 range ( defined as +/-5% of the individual rStO2 median of each infant during each period
研究概览
简要总结
Background: fluctuation of cerebral blood flow and oxygenation in neonates who undergo intensive care is an important risk factor for risk of neurodevelopmental impairment. Near infrared spectroscopy (NIRS) allow direct measurements of cerebral tissue oxygenation. Automated Fraction of Inspired Oxygen (FiO2) adjustment can maintain arterial oxygen saturation (SpO2) within a target range and may reduce risk of fluctuation of cerebral oxygenation.
Aim of this study: to evaluate the efficacy of automated FiO2 adjustment in maintaining SpO2 within a target range and in reducing the risk of cerebral tissue hypo-oxygenation due to SpO2 fluctuations in preterm infants on invasive or non invasive respiratory support with supplemental oxygen.
详细描述
Background: fluctuation of cerebral blood flow and oxygenation in neonates who undergo intensive care is an important risk factor for risk of neurodevelopmental impairment. Near infrared spectroscopy (NIRS) allow direct measurements of cerebral tissue oxygenation. Automated FiO2 adjustment can maintain arterial oxygen saturation (SpO2) within a target range and may reduce risk of fluctuation of cerebral oxygenation.
Aim of this study: to evaluate the efficacy of automated FiO2 adjustment in maintaining SpO2 within a target range and in reducing the risk of cerebral tissue hypo-oxygenation due to SpO2 fluctuations in preterm infants on invasive or non invasive respiratory support with supplemental oxygen.
Methodology: multicenter randomized cross-over clinical trial. The study will be carried out for almost 1 year .
Study centers: 7 Italian Neonatal Intensive Care Units (NICUs) Number of subjects: 60 infants to have a >90% power, with an alpha of p=0.01, of detecting a 5% difference in %-time in the target range and a 50% difference in both SpO2 hyperoxic and hypoxic %-time.
Diagnosis and main inclusion criteria: preterm infants of 25+0-28+6 weeks of gestational age, requiring invasive or non invasive respiratory support and supplemental oxygen.
研究设计
- 研究类型
- Interventional
- 分配方式
- Randomized
- 干预模型
- Crossover
- 主要目的
- Supportive Care
- 盲法
- None
入排标准
- 年龄范围
- 72 Hours 至 7 Days(Child)
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •preterm infants of 25+0-28+6 weeks of gestational age, requiring invasive or non invasive respiratory support and supplemental oxygen
排除标准
- •infants with major congenital anomalies, haemodinamic instability, or requiring cathecolamines treatment,clinical evidence of seizures or ongoing sepsis (positive blood culture) during the study, or within 24 hours prior enrollment
结局指标
主要结局
the burden of hypoxemia on regional cerebral saturation (rStO2) calculated as area under curve (AUC-% second) below the individual median rStO2 range ( defined as +/-5% of the individual rStO2 median of each infant during each period
时间窗: 24 hours
burden of hypoxemia on rStO2
次要结局
- AUC above the individual median rStO2 and time (% of the total recording time) within the SpO2 target range (91-95%)(24 hours)
研究者
Gianluca Lista,MD
MD
ASST Fatebenefratelli Sacco
