Evaluation of Negative Inspiratory Flow in Children With Acute Asthma

Not Applicable
Completed
Conditions
Asthma
Interventions
Device: In-Check Dial
Device: Inhaler Device
Registration Number
NCT05762978
Lead Sponsor
Winthrop University Hospital
Brief Summary

There are different inhalers used for the treatment of asthma and they work differently and require different technique for the optimal drug delivery to the lungs. One of the inhalers is the Dry Powder Inhaler (DPI). The minimal amount of Negative Inspiratory Flow (NIF) required to use this medication is 30ml/min. Studies have shown that children find it difficult to generate this NIF and studies have also shown that children generate lesser NIF during an Asthma exacerbation. The investigators will measure the NIF using an InCheck Dial on children with asthma during an exacerbation and when they are seen in clinic for a hospital follow up visit. This will be done on asthmatic children regardless of the inhaler that they use. The investigator hypothesize that children with asthma age 4-8 years cannot generate the required NIF during an Asthma exacerbation hence proving that a DPI cannot be prescribed to children at this age. This study will examine this hypothesis.

Detailed Description

Inhaler devices are the major method for delivery of asthma medication, but their effectiveness can be compromised if the patient uses the inhaler device incorrectly. The magnitude of this problem has been well documented; in several studies less than half of the patients used their inhaler correctly. Inhaler devices are used to deliver a variety of inhaled medications, including beta-agonists, anticholinergic, and glucocorticoids. Two main types of inhaler devices are available, the pressurized metered dose inhaler (pMDI) and the dry powder inhaler (DPI).

A dry powder inhaler (DPI) is a breath-actuated device containing micronized drug particles with a mass median aerodynamic diameter (MMAD) of less than 5 µm that are usually aggregated with carrier particles (such as lactose or glucose) of greater diameter. Drug is delivered to the airways by the inhalation of air over a punctured drug-containing capsule or blister.

In this study investigators will evaluate the use of DPI use in children during an acute asthma exacerbation. The investigators hypothesize the use of DPI in children ages 4-8 during an asthma exacerbation has limited benefit, as children are unable to generate the needed NIF. The investigators will study children who were hospitalized for an acute asthma exacerbation. Additionally, the investigators will evaluate the participant as an outpatient in the pulmonary clinic / office when the participant is without an asthma exacerbation.

Recruitment & Eligibility

Status
COMPLETED
Sex
All
Target Recruitment
7
Inclusion Criteria
  • Hospitalized with asthma
  • Age ≥ 4 years and < 8 years
Exclusion Criteria
  • Acute Lung Disease
  • Chronic lung disease
  • Developmental Delay

Study & Design

Study Type
INTERVENTIONAL
Study Design
SINGLE_GROUP
Arm && Interventions
GroupInterventionDescription
Asthmatic ChildrenIn-Check DialNIF will be measured using an In-Check Dial
Asthmatic ChildrenInhaler DeviceNIF will be measured using an In-Check Dial
Primary Outcome Measures
NameTimeMethod
NIF (Negative Inspiratory Flow)Follow-Up Visits (Week 2 Post-Discharge)

NIF measures a patient's maximum inspiratory effort after exhaling.

Secondary Outcome Measures
NameTimeMethod

Trial Locations

Locations (1)

Winthrop University Hospital

🇺🇸

Mineola, New York, United States