Preoperative Radiographic Evaluation of Medial Tibiofemoral Knee Osteoarthritis
- Conditions
- Arthritis Knee
- Registration Number
- NCT03704558
- Lead Sponsor
- Rennes University Hospital
- Brief Summary
Observational study.
- Detailed Description
In advanced stage osteoarthritis or osteonecrosis of the articular bearing surfaces of the knee, the surgical therapeutic solutions consist of a replacement of the articular surfaces by prosthetic implants. Depending on whether these implants replace all or part of the articular surfaces they are called "total" or "uni compartmental" knee prosthesis.
The uni-compartmental medial prosthesis replaces only the medial tibiofemoral compartment of the knee and is therefore intended for patients with cartilaginous wear isolated from this compartment.
The uni-compartmental medial prosthesis has advantages over the total knee arthroplasty of being more economical in articular tissues of the knee, having better functional results and lower complication rates. Although this is debated, the survival rate of uni-compartmental prostheses in the international registers is lower than that of total knee prostheses.
One of the most common early failure factors of uni-compartmental prostheses is the absence of a functional anterior cruciate ligament. Other factors have also been identified and are sometimes highly debated such as the Kozinn and Scott criteria. The group of designers of the unicompartmental Oxford Uni compartmental prosthesis Knee Arthroplasty (OUKA) (Zimmer Biomet, Warsaw) proposed and validated expanded criteria. These criteria, exclusively radiographic, are grouped in a document called "decision aid" to check the functional status of the collateral ligaments medial and anterior cross, other compartments of the knee (lateral femoro-tibial and femoro-patellar).
In decision aid, the functional status of the anterior cruciate ligament is judged on the knee radiograph by the location of the osteoarthritic cup. If it is present and functional, the cartilaginous wear is anterior with a respect of the posterior portion of the tibial plateau.
After regular use of the French version of the decision aid, the assessment of the location of osteoarthritis seems subjective to us however it is essential to validate the indication of a uni-compartmental prosthesis. In case of poor evaluation, the risk is the intraoperative discovery of the actual status of the anterior cruciate ligament that may result in a change of indication and the installation of a total knee prosthesis. The investigators have not found in the literature, studies evaluating the reliability and reproducibility of the lateral radiograph to judge the functional status of the anterior cruciate ligament.
The hypothesis is that the lateral radiograph is unreliable and reproducible to judge the functional status of the anterior cruciate ligament in a population of patients with medial femoro-tibial knee osteoarthritis.
Recruitment & Eligibility
- Status
- WITHDRAWN
- Sex
- All
- Target Recruitment
- Not specified
- Patient aged 18 years or over;
- presenting with medial femoral tibial osteoarthritis;
- Indication of a TKA or a medial PUC of first intention;
- Validation of the surgical indication at orthopedic surgery staff;
- Not having expressed his opposition to participate in the study.
- Major person subject to legal protection (safeguard of justice, guardianship, guardianship);
- Person deprived of liberty;
- Pregnant or nursing woman.
Study & Design
- Study Type
- OBSERVATIONAL
- Study Design
- Not specified
- Primary Outcome Measures
Name Time Method Correlation Baseline Correlation rate between compliance with the posterior third of the radiologically assessed tibial plateau and the functional status of the anterior cruciate ligament
- Secondary Outcome Measures
Name Time Method Reproducibility Baseline Inter and intra-observer reproducibility of the preoperative radiological analysis: size of the wear cup, distance posterior edge of the tray - cup, respect of the posterior third and functional status of the anterior cruciate ligament
Reliability Baseline Reliability of profile radio: correlation rate between radiological and intraoperative data