Clinical Study to Evaluate the Safety and Performance of the enVista® One-Piece Hydrophobic Acrylic Trifocal Intraocular Lens in Subjects Undergoing Cataract Extraction
- Conditions
- Cataract
- Interventions
- Device: enVista MX60EFH trifocal intraocular lenses (IOLs)Device: enVista MX60E monofocal intraocular lenses (IOLs)
- Registration Number
- NCT04224155
- Lead Sponsor
- Bausch & Lomb Incorporated
- Brief Summary
The objective of the study is to evaluate the safety and performance of the enVista trifocal intraocular lens when implanted in the capsular bag.
- Detailed Description
Not available
Recruitment & Eligibility
- Status
- COMPLETED
- Sex
- All
- Target Recruitment
- 165
- Subjects must be 18 years of age or older on the date the Informed Consent Form (ICF) is signed.
- Subjects must have the capability to understand and provide written informed consent on the Institutional Review Board (IRB)/Independent Ethics Committee (IEC) approved Informed Consent Form (ICF) and authorization as appropriate for local privacy regulations.
- Subjects must have a Best-corrected Distance Visual Acuity (CDVA) equal to or worse than 20/40 in at least one eye, with or without a glare source, due to a clinically significant cataract (cortical, nuclear, subcapsular, or combination) that is considered amenable to treatment with standard phacoemulsification cataract extraction and capsular IOL implantation.
- Subjects must have a Best-corrected Distance Visual Acuity (CDVA) projected to be equal to or better than 20/32 after IOL implantation in each eye, as determined by the medical judgment of the Investigator or measured by potential acuity meter (PAM) testing, if necessary.
- Subjects must have clear intraocular media other than the cataract in both eyes.
- Subjects must have discontinued use of contact lenses for at least 2 weeks (for hard lenses) or 3 days (for soft lenses) prior to the pre-operative examination and must be willing to refrain from use of contact lenses throughout the clinical study.
- Contact lens wearers must demonstrate a stable refraction (within ±0.50 D for both sphere and cylinder) in both eyes, as determined by distance manifest refraction on two consecutive examination dates after discontinuation of contact lens wear.
- Subjects must require an IOL power from +16.0 diopter (D) to +27.0 D in both eyes.
- Subjects must be willing and able to comply with all treatment and follow-up study visits and procedures, and to undergo second eye surgery within 7-30 days of the first eye surgery.
- Subjects who have participated in an investigational drug or device clinical investigation within 30 days prior to entry into this study and/or will participate in another investigation during the period of study participation.
- Subjects who have any corneal pathology (e.g., significant scarring, guttata, inflammation, edema, dystrophy, etc.) in either eye. . '
- Subjects who have significant anterior segment pathology that might increase intraoperative risk or compromise IOL stability (e.g., pseudoexfoliation syndrome, synechiae, iris atrophy, traumatic cataract, lens subluxation, traumatic zonulolysis, zonular dialysis, evident zonular weakness or dehiscence, hypermature or brunescent cataract, etc.) in either eye.
- Subjects who have uncontrolled glaucoma in either eye.
- Subjects who have previous retinal detachment or clinically significant retinal pathology involving the macula in either eye.
- Subjects who have proliferative or non-proliferative diabetic retinopathy in either eye.
- Subjects who have a congenital ocular anomaly (e.g., aniridia, congenital cataract) in either eye.
- Subjects with instability of keratometry or biometry measurements.
- Subjects using any systemic or topical drug known to interfere with visual performance, pupil dilation, or iris structure within 30 days of enrollment or during the study.
- Subjects who have current or previous usage of an alpha-I-selective adrenoceptor blocking agent or an antagonist of alpha IA adrenoceptor (e.g., Flomax® (tamsulosin HCI), Terazosin, or Cardura).
- Subjects who have a history of chronic or recurrent inflammatory eye disease (e.g., iritis, scleritis, iridocyclitis, or rubeosis iridis) in either eye.
- Subjects who have a visual disorder, other than cataracts, that could potentially cause future acuity losses to a level of 20/ I 00 or worse in either eye.
- Subjects who have had previous intraocular or corneal surgery in either eye, with the exception of laser trabeculoplasty.
- Subjects with any preoperative infectious conjunctivitis, keratitis, or uveitis in either eye.
- Subjects who have a preoperative corneal astigmatism> 1.0 D in either eye as measured by corneal topography, irregular astigmatism, or skewed radial axis (note: corneal incisions intended specifically to reduce astigmatism are not allowed during the study).
- Subjects who cannot achieve a minimum pharmacologic pupil dilation of 5.0 mm in both eyes.
- Subjects who may be expected to require a combined or other secondary surgical procedure in either eye.
- Females of childbearing potential (those who are not surgically sterilized or at least 12 months postmenopausal) are excluded from enrollment in the study if they are nursing, lactating, currently pregnant or plan to become pregnant during the study. Females of childbearing potential must be willing to practice effective contraception for the duration of the study.
- Subjects with any other serious ocular pathology or underlying systemic medical condition (e.g., uncontrolled diabetes) or circumstance that, based on the Investigator's judgment, poses a concern for the subjects' safety or could confound the results of the study.
- Subjects with abnormal pupillary dilation dynamics (as determined by the medical judgment of the investigator) or eccentric or ectopic pupils in either eye.
Study & Design
- Study Type
- INTERVENTIONAL
- Study Design
- PARALLEL
- Arm && Interventions
Group Intervention Description enVista MX60EFH trifocal intraocular lens (IOL) enVista MX60EFH trifocal intraocular lenses (IOLs) - enVista MX60E monofocal intraocular lens (IOL) enVista MX60E monofocal intraocular lenses (IOLs) -
- Primary Outcome Measures
Name Time Method Serious Adverse Events Day 120 to Day 180 after second eye IOL implantation All serious adverse events through Post-Operative Visit 4 (Day 120 to Day 180 after second eye IOL implantation)
Cumulative Rate of Secondary Surgical Interventions Due to the Optical Properties of the Lens Day 120 to Day 180 after second eye IOL implantation The cumulative rate of secondary surgical interventions (SSI) due to the optical properties of the lens, through Post-Operative Visit 4 (Day 120 to Day 180 after second eye IOL implantation). The rate was determined as the number of eyes with an SSI related to the optical properties of the IOL divided by the total number of eyes.
Photopic Uncorrected Distance Visual Acuity (UDVA) for First Implanted Eyes Day 120 to Day 180 after second eye IOL implantation Photopic uncorrected distance visual acuity (UDVA) for first implanted eyes at 4 m at Post.Operative Visit 4 (Day 120 to Day 180 after second eye IOL implantation)
Photopic Uncorrected Near and Intermediate Visual Acuity (UNVA and UIVA) for First Implanted Eyes at 40 cm and 66 cm, Respectively Day 120 to Day 180 after second eye IOL implantation Photopic uncorrected near and intermediate visual acuity (UNVA and UIVA) for first implanted eyes at 40 cm and 66 cm, respectively, at Post-Operative Visit 4 (Day 120 to Day 180 after second eye IOL implantation)
The Incidence of Adverse Events (AEs), Through Postoperative Visit 4 (Day 120 to Day 180 After Second Eye IOL Implantation), Compared to ISO Safety and Performance Endpoint Rates. Day 120 to Day 180 after second eye IOL implantation The incidence of adverse events (AEs), through Postoperative Visit 4 (Day 120 to Day 180 after second eye IOL implantation), compared to ISO Safety and Performance Endpoint rates as defined in ISO 11979-7:2018 and EN ISO 11979-7:2018 Annex E. The observed AE rate was calculated as 100 multiplied by the number of eyes with the specific treatment-emergent event divided by the number of implanted eyes.
- Secondary Outcome Measures
Name Time Method Incidence of Subjects Experiencing at Least One Severe Visual Disturbance Day 120 to Day 180 after second eye IOL implantation The incidence of Patient-Reported Outcomes Set subjects experiencing at least one severe visual disturbance, defined as the highest grade of severity or bothersomeness (separately) reported by subjects using the Quality of Vision (QoV) questionnaire at Post-Operative Visit 4 (Day 120 to Day 180 after second eye IOL implantation). Incidence was calculated as 100 multiplied by Count of Participants experiencing at least one severe visual disturbance divided by Number of Participants Analyzed.
Photopic Contrast Sensitivity With Glare at Post-Operative Visit 4 Day 120 to Day 180 after second eye IOL implantation Photopic contrast sensitivity with glare at Post-Operative Visit 4 (Day 120 to Day 180 after second eye IOL implantation).
Binocular photopic (approximately 85 cd/m2) contrast sensitivity with glare was tested at spatial frequencies of 3, 6, 12 and 18 cycles per degree (cpd) and was assessed in log units.Mesopic Contrast Sensitivity With Glare at Post-Operative Visit 4 Day 120 to Day 180 after second eye IOL implantation Mesopic contrast sensitivity with glare at Post-Operative Visit 4 (Day 120 to Day 180 after second eye IOL implantation). Binocular mesopic (2.5 to 3.2 cd/m2) contrast sensitivity with glare was tested at spatial frequencies of 1.5, 3, 6 and 12 cpd and was assessed in log units.
Mesopic Contrast Sensitivity Without Glare at Post-Operative Visit 4 Day 120 to Day 180 after second eye IOL implantation Mesopic contrast sensitivity without glare at Post-Operative Visit 4 (Day 120 to Day 180 after second eye IOL implantation). Binocular mesopic (2.5 to 3.2 cd/m2) contrast sensitivity without glare was tested at spatial frequencies of 1.5, 3, 6 and 12 cpd and was assessed in log units.
IOL Rotation for All Eyes at Post-Operative Visit 4 Day 120 to Day 180 after second eye IOL implantation IOL rotation for all eyes at Post-Operative Visit 4 (Day 120 to Day 180 after second eye IOL implantation)
Change From Baseline ( Preoperative ) in Uncorrected Photopic Near and Intermediate Visual Acuity (UNVA and UIVA) at 40 cm and 66 cm, Respectively, for First Implanted Eyes to Post-Operative Visit 4 Day 120 to Day 180 after second eye IOL implantation Change from baseline ( preoperative ) in uncorrected photopic near and intermediate visual acuity (UNVA and UIVA) at 40 cm and 66 cm, respectively, for first implanted eyes to Post-Operative Visit 4 (Day 120 to Day 180 after second eye IOL implantation)
Trial Locations
- Locations (9)
Bausch Site 108
🇨🇦Vaughan, Ontario, Canada
Bausch Site 104
🇨🇦Montréal, Quebec, Canada
Bausch Site 106
🇨🇦Calgary, Alberta, Canada
Bausch Site 103
🇨🇦Mississauga, Ontario, Canada
Bausch Site 101
🇨🇦Boisbriand, Quebec, Canada
Bausch Site 113
🇨🇦Longueuil, Quebec, Canada
Bausch Site 102
🇨🇦Concord, Ontario, Canada
Bausch Site 105
🇨🇦Toronto, Ontario, Canada
Bausch Site 107
🇨🇦Toronto, Ontario, Canada