Effectiveness Analysis of Armeo Spring Device as a Rehabilitation Treatment in Spinal Cord Injured Patients
试验速览
- 阶段
- 不适用
- 状态
- 已完成
- 入组人数
- 34
- 试验地点
- 2
- 主要终点
- Edinburg Handedness Test
研究概览
简要总结
Loss of motor function is a consequence after a spinal cord injury (SCI). The incidence of SCI varies greatly from 12.1 to 57.8 cases per million depending on the country. More than 50% of people with SCI have impaired upper limb (UL) function, experiencing limitations in performing functional tasks. In this context, one of the rehabilitation objectives is to achieve the maximum level of independence in the patient in the performance of activities of daily living (ADL).
Within the clinical setting, the main motivation in the use of robotic devices and/or exoskeletons for a rehabilitation purpose focuses on the fact that these help therapists in administering repetitive manual therapies to patients during exercises. There is evidence that the amount of therapy patients receive is insufficient. Without creating additional time demands on clinicians, robotic devices can perform the repetitive mechanical aspects of therapy, increasing the amount of therapy that patients receive. However, the current evidence in stroke patients suggests that the improvements observed are due to the intensity of the therapy, regardless of whether the administration of rehabilitation is due to robotic devices and/or traditional means.
The main objective of this study is to analyze the effectiveness of the commercial Armeo® Spring system (Hocoma AG, Switzerland) and a Virtual Reality application to repeatedly work the ADL from drinking from a glass, in people with cervical SCI. The ADL of drinking has been chosen, as a representative activity of those related to food, which requires control, strength and coordination of the UL. The study is carried out at the Hospital Nacional de Parapléjicos with the collaboration of Occupational Therapy Unit, the Rehabilitation Department, and the Biomechanics and Technical Aids Unit. This effectiveness is measured in terms of functional improvements and in the quality of the UL movements performed.
详细描述
In the literature, there are several studies of the upper limb applied to ADL. The analysis of complete ADL is related to the clinical objectives of the rehabilitative treatment of the UL. An important part of rehabilitation after neurological injuries consists of training activities aimed at fulfilling a function or objective, in which patients have to move their arms continuously repeating certain movement patterns. This is currently one of the main strategies to promote recovery of upper limb function in people who have suffered a spinal cord injury (SCI) o stroke.
Within the clinical setting, the main motivation in the use of robotic devices and/or exoskeletons for a rehabilitation purpose focuses on the fact that these help therapists in administering repetitive manual therapies to patients during exercises. There is evidence that the amount of therapy patients receive is insufficient. Without creating additional time demands on clinicians, robotic devices can perform the repetitive mechanical aspects of therapy, increasing the amount of therapy that patients receive. On the other hand, the use of robotic devices is closely linked to the use of virtual reality (VR) applications. VR interfaces provide feedback to the patient, increasing their level of motivation and adherence to the task during therapy. In this way, therapies with robotic devices and / or exoskeletons increase the amount of rehabilitation, the level of motivation of the patient, and training oriented to fulfill a function or task. Rehabilitation of patients with robotic device-based therapies in addition to traditional therapies could improve functional outcomes. However, the current evidence in stroke patients suggests that the improvements observed are due to the intensity of the therapy, regardless of whether the administration of rehabilitation is due to robotic devices and/or traditional means.
The main objective of this study is to analyze the effectiveness of the commercial Armeo® Spring system (Hocoma AG, Switzerland) and a Virtual Reality application to repeatedly work the ADL from drinking from a glass, in people with cervical SCI. The ADL of drinking has been chosen, as a representative activity of those related to food, which requires control, strength and coordination of the UL. The study is carried out at the Hospital Nacional de Parapléjicos with the collaboration of Occupational Therapy Unit, the Rehabilitation Department, and the Biomechanics and Technical Aids Unit. This effectiveness is measured in terms of functional improvements and in the quality of the UL movements performed.
The secondary objectives are:
- To validate the applicability of the Virtual Reality developed to work the upper limb during the execution of a complete AVD.
- To know the usability and level of acceptance of this therapy in patients with spinal cord injury and UL functional impairments.
- To quantify the differences between the functional patterns of both groups, intervention and control, by means of objective measures, functional scales and measures of the quality of movement, collected in patient evaluations, before, during and after treatment.
- To determine the influence of the RV and the Armeo Spring exoskeleton on the motor recovery of patients with spinal cord injury and UL impairments.
研究设计
- 研究类型
- Interventional
- 分配方式
- Randomized
- 干预模型
- Parallel
- 主要目的
- Treatment
- 盲法
- Single (Outcomes Assessor)
入排标准
- 年龄范围
- 16 Years 至 75 Years(Child, Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •Cervical lesions above C8, incomplete in the motor aspect or complete with zones of partial motor preservation at least C6, classified according to the ASIA scale.
- •Traumatic or non-progressive medical etiology.
- •Less than 6 months of injury evolution (subacute).
- •Age between 16 and 75 years.
- •To have reached the seated posture.
- •Be informed and consent to participate in the study.
排除标准
- •Unstable orthopaedic injuries such as unconsolidated fractures or with unstable osteosynthesis systems in upper limbs.
- •Skin lesions and/or pressure ulcers in the exoskeleton placement area.
- •Having joint stiffness and/or severe spasticity.
- •Bronchopneumopathy and/or severe heart disease that will require monitoring during exercise.
- •Visual problems.
- •Cognitive impairment.
- •Do not sign the corresponding informed consent.
结局指标
主要结局
Edinburg Handedness Test
时间窗: At baseline
Most people are right handed. The Edinburgh Handedness Inventory is a well known short questionnaire for determining objectively whether one is left or right handed and there is a short form of it. 10 items are valued. The total score is 50 points and the minimum 10 points. The closer score to 50 points, more left-handed the person is. And the closer score to 10 the more right-handed.
Change from baseline Kinematic indices at 10 weeks
时间窗: At the end of the study (at week 10)
This assessment is performed by means of photogrammetry. Markers are placed on the trunk and the arm analyzed, and kinematic variables about the UL movement are computed in terms of accuracy, agility, coordination, efficiency and smoothness. A score of 100 in each index corresponds to the healthy pattern. The minimun and worse outcome is 0 score.
Clinical Scale GRASSP
时间窗: At baseline
The GRASSP is a clinical impairment measure specific to the upper limb for use after tetraplegia. The GRASSP measure sensorimotor and prehension function through three domains, important in describing arm and hand function: Strength, Sensation, Prehension. The minimal score is 0 (worse outcome) and the maximum 98 (better outcome) for each hand.
Clinical scale SCIM
时间窗: At baseline
The Spinal Cord Independence Measure (SCIM) is a new disability scale developed specifically for patients with spinal cord lesions in order to make the functional assessments of patients with paraplegia or tetraplegia more sensitive to changes. Exclusively designed for spinal injury. It consists of 3 subscales. The total score varies from 0-100 points, where 0 corresponds to the highest degree of dependency and 100 to the highest degree of independence.
Change from baseline Clinical scale Nine Hole Peg Test at 10 weeks
时间窗: At the end of the study (at week 10)
The Nine-Hole Peg Test (9-HPT) is a standardized, quantitative assessment used to measure finger dexterity. The scale measures the time in seconds in reaching each task. A higher spent time is a worse outcome.
Change from baseline Clinical Scale GRASSP at 10 weeks
时间窗: At the end of the study (at week 10)
The GRASSP is a clinical impairment measure specific to the upper limb for use after tetraplegia. The GRASSP measure sensorimotor and prehension function through three domains, important in describing arm and hand function: Strength, Sensation, Prehension. The minimal score is 0 (worse outcome) and the maximum 98 (better outcome) for each hand.
Change from baseline Clinical scale SCIM at 10 weeks
时间窗: At the end of the study (at week 10)
The Spinal Cord Independence Measure (SCIM) is a new disability scale developed specifically for patients with spinal cord lesions in order to make the functional assessments of patients with paraplegia or tetraplegia more sensitive to changes. Exclusively designed for spinal injury. It consists of 3 subscales. The total score varies from 0-100 points, where 0 corresponds to the highest degree of dependency and 100 to the highest degree of independence.
Clinical scale CUE
时间窗: At baseline
Capabilities of Upper Extremity (CUE) measures upper extremity functional limitations in individuals with tetraplegia. The patient reports the outcome about how well you are able to use the arms and hands of patients. 32 item questionnaire with items in 7 domains. Self-reported measure performed by interview. Score on 7 points scale representing self-perceived difficulty: 1 (Totally limited, can´t do at all) y 7 (Not at all limited). So, the minimum score is 32 (worse result) and the maximum score 224 (greater function)
Change from baseline Clinical scale CUE at 10 weeks
时间窗: At the end of the study (at week 10)
Capabilities of Upper Extremity (CUE) measures upper extremity functional limitations in individuals with tetraplegia. The patient reports the outcome about how well you are able to use the arms and hands of patients. 32 item questionnaire with items in 7 domains. Self-reported measure performed by interview. Score on 7 points scale representing self-perceived difficulty: 1 (Totally limited, can´t do at all) y 7 (Not at all limited). So, the minimum score is 32 (worse result) and the maximum score 224 (greater function)
Clinical Scale Jebsen-Taylor Hand Function (JTHF)
时间窗: At baseline
The Jebsen-Taylor function test was designed to provide a short, objective test of hand functions commonly used in activities of daily living (ADLs). The target patient population includes adults with neurological or musculoskeletal conditions involving hand disabilities, although there may be other patient populations with other hand dysfunctions which may be appropriate. It consists of seven items that include a range of fine motor, weighted and non-weighted hand function activities which are timed: writing (copying) a 24-letter sentence turning over a 3 × 5" cards, picking up small common objects such as a coin and bottle cap, simulated feeding using a teaspoon and five kidney beans, stacking checkers picking up large light objects such as an empty tin can, and picking up and moving large weighted cans. The scale measures the time in seconds in reaching each task. A higher spent time is a worse outcome.
Change from baseline Clinical Scale Jebsen-Taylor Hand Function (JTHF) at 10 weeks
时间窗: At the end of the study (at week 10)
The Jebsen-Taylor function test was designed to provide a short, objective test of hand functions commonly used in activities of daily living (ADLs). The target patient population includes adults with neurological or musculoskeletal conditions involving hand disabilities, although there may be other patient populations with other hand dysfunctions which may be appropriate. It consists of seven items that include a range of fine motor, weighted and non-weighted hand function activities which are timed: writing (copying) a 24-letter sentence turning over a 3 × 5" cards, picking up small common objects such as a coin and bottle cap, simulated feeding using a teaspoon and five kidney beans, stacking checkers picking up large light objects such as an empty tin can, and picking up and moving large weighted cans. The scale measures the time in seconds in reaching each task. A higher spent time is a worse outcome.
Clinical scale Nine Hole Peg Test
时间窗: At baseline
The Nine-Hole Peg Test (9-HPT) is a standardized, quantitative assessment used to measure finger dexterity. The scale measures the time in seconds in reaching each task. A higher spent time is a worse outcome.
Kinematic indices
时间窗: At baseline
This assessment is performed by means of photogrammetry. Markers are placed on the trunk and the arm analyzed, and kinematic variables about the UL movement are computed in terms of accuracy, agility, coordination, efficiency and smoothness. A score of 100 in each index corresponds to the healthy pattern. The minimun and worse outcome is 0 score.
次要结局
- Hospital Anxiety and Depression Scale (HADS)(At baseline)
- Compliance(At the end of the study (at week 10))
- Change from baseline TMS assessment at 10 weeks(At the end of the study (at week 10))
- QUEST usability scale(At the end of the study (at week 10))
- TMS assessment(At baseline)
- Beck's Depression Inventory(At baseline)
- Change from baseline Beck's Depression Inventory at 10 weeks(At the end of the study (at week 10))
- Change from baseline Hospital Anxiety and Depression Scale (HADS) at 10 weeks(At the end of the study (at week 10))
研究者
Ana de los Reyes Guzmán
Principal Investigator
Hospital Nacional de Parapléjicos de Toledo