跳至主要内容
临床试验/NCT04018014
NCT04018014Unknown不适用

Low-dose CT Angiography in the Detection of Acute Pulmonary Embolism: Validation in an Obese Population

University Hospital, Clermont-Ferrand1 个研究点 分布在 1 个国家目标入组 130 人开始时间: 2019年3月21日最近更新:
适应症

试验速览

阶段
不适用
发起方
入组人数
130
试验地点
1
主要终点
Unit of hounsfield (UH) measurement in region of interest (ROI)

研究概览

简要总结

Pulmonary embolism is a common pathology in the general population, whose suspicion is based on the clinical and dosage of D-dimers in particular.

The key examination for the diagnosis of pulmonary embolism is chest CT angiography (negative predictive value of 98%).

The evolution of machines in recent years allows a reduction of possible kilovoltage up to 80 kV, different computer algorithms (iterative reconstructions) to reconstruct the images and thus reduce the irradiation dose with equal image quality (Evaluation of dose CT and adaptive statistical reconstruction with the same group of patients, Qi et al, 2012; Impact of iterative reconstruction on the diagnosis of acute pulmonary embolism (PE) on reduced-dose chest CT angiograms, Pontana et al , 2015) in patient populations with a weight of less than 100 kilos.

However, obesity is a risk factor for pulmonary embolism and the obese population is increasing, thus requiring optimal management regarding irradiation.

Few studies have evaluated the quality of low dose CT angiography in obese patients. One study showed the possibility of performing low-dose thoracic CT angiography (100 kV) in patients up to 125 kg, without loss of subjective quality (but with an impact on objective quality), without the use of current iterative reconstruction techniques (Diagnostic confidence and image quality of CT pulmonary angiography at 100 kVp in overweight and obese patients, Megyeri et al, 2015).

The study seek to prove that in the obese patient, with a low dose examination (voltage of the tube at 100 kV) and the current iterative reconstructions, the thoracic angioscanner is not less efficient than in the non obese patient, that the qualities objective and subjective analyzes are maintained.

The main purpose is to evaluate and compare thoracic CT angiography with weight and BMI, with identical CT parameters (same voltage, computer reconstruction techniques and same contrast injection protocol), by evaluating the objective and subjective diagnostic quality of the opacification of the pulmonary arteries.

详细描述

The study is monocentric, realised in University Hospital of Clermont-Ferrand, France, using the CT GE Revolution dedicated to the emergency service.

For each patient with suspicion of pulmonary embolism, regarding the inclusion and exclusion criteria (explained later), investigators realise the same protocol.

Patients are divided into 2 groups of weight : <30 kg/m2, > 30 kg/m2. There is no change in the management of patients, who benefit from an angioscan for pulmonary embolism, with an optimized protocol for patients under 100 kg and validated by the literature (Megyeri et al. , 2015) for patients over 100 kilos, with no loss of diagnostic chance and with an improvement over the irradiation compared to the usual protocols used (over-irradiation in the obese, up to 140 kV).

Concerning the CT protocol, a voltage of 100 kV is applied (irradiation 40% lower than a 120 kV test), with a modulation of the intensity of the current according to the Z axis and use of different levels of iterative reconstructions on images obtained to improve diagnostic performance.

Regarding the injection protocol, the same product with high concentration of iodine is injected to all patients (IOMERON 400), with a quantity relative to the weight of 1 mL / kg of patient weight, a maximum of 90 mL, a rate of 4 mL / s and rinsing with 30 mL of saline solution at 3 mL / sec

研究设计

研究类型
Observational
观察模型
Cohort
时间视角
Prospective

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • 未提供

排除标准

  • 未提供

结局指标

主要结局

Unit of hounsfield (UH) measurement in region of interest (ROI)

时间窗: Day 0

Unit of hounsfield (UH) measurement in region of interest (ROI) in the pulmonary artery, right and left branches, lobar branches, one segmental and subsegmental branch for each lobe, signal / noise ratio and contrast / noise for each ROI

次要结局

  • Scale of confidence (Likert)(Day 0)

研究者

发起方
University Hospital, Clermont-Ferrand
申办方类型
Other
责任方
Sponsor

研究点 (1)

Loading locations...

相似试验