跳至主要内容
临床试验/NCT07488052
NCT07488052
招募中
不适用

Prospective Multicenter Validation of a Home-Based AI-Enabled Single-Lead ECG for Detecting Low Ejection Fraction and Structural Heart Disease

National Defense Medical Center, Taiwan1 个研究点 分布在 1 个国家目标入组 5,000 人开始时间: 2026年3月1日最近更新:

概览

阶段
不适用
状态
招募中
发起方
National Defense Medical Center, Taiwan
入组人数
5,000
试验地点
1
主要终点
Area Under the Receiver Operating Characteristic Curve for Detection of Low Left Ventricular Ejection Fraction

概览

简要总结

This prospective multicenter observational study will validate the accuracy of a previously developed artificial intelligence-enabled single-lead electrocardiogram (AI-ECG) model for identifying low heart pumping function and other structural heart disease phenotypes. Adult participants receiving a model-compatible single-lead ECG (Apple Watch and QOCA ECG102D) and transthoracic echocardiography at five hospitals in Taiwan will be enrolled between March 1, 2026 and June 30, 2026. AI model predictions will be compared with echocardiographic reference standards obtained after the index ECG within 30 days.

研究设计

研究类型
Observational
观察模型
Cohort
时间视角
Prospective

入排标准

年龄范围
20 Years 至 90 Years(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Age 20 years or older
  • Single-lead ECG recorded using a study-compatible device
  • Ability to comply with study procedures and, when applicable, provide informed consent according to local IRB requirements
  • Without Transthoracic echocardiography within 90 days before the index ECG

排除标准

  • ECG signal quality insufficient for prespecified AI analysis
  • Without Transthoracic echocardiography available within 30 days after the index ECG
  • Echocardiography unavailable or technically inadequate for determining EF

结局指标

主要结局

Area Under the Receiver Operating Characteristic Curve for Detection of Low Left Ventricular Ejection Fraction

时间窗: 30 days

AUC with 95% confidence interval for detection of low EF, defined as echocardiographic LVEF ≤40%, by the pre-specified AI-enabled single-lead ECG model.

Sensitivity, Specificity, Positive Predictive Value, and Negative Predictive Value for Low EF Detection at the Pre-specified Operating Threshold

时间窗: 30 days

Diagnostic operating characteristics of the locked AI model for low EF at the pre-specified threshold.

次要结局

  • Positive Predictive Value and Negative Predictive Value for Structure Heart Disease at the Pre-specified Operating Threshold(30 days)
  • The Difference of Mortality Risk at the Pre-specified Operating Threshold(90 days)

研究者

发起方
National Defense Medical Center, Taiwan
申办方类型
Other
责任方
Principal Investigator
主要研究者

Chin Lin

Professor

National Defense Medical Center, Taiwan

研究点 (1)

Loading locations...

相似试验