跳至主要内容
临床试验/NCT03526198
NCT03526198已完成不适用

Quantification of Distribution of the Mass Center for a Controlled Force Platform Reaction to the Ground

Universidade Cruzeiro do Sul0 个研究点目标入组 30 人开始时间: 2016年7月1日最近更新:
适应症
干预措施

试验速览

阶段
不适用
状态
已完成
入组人数
30
主要终点
Mass distribution

研究概览

简要总结

This study developed a controlled soil reaction force platform that provided controlled mechanical stimuli to quantify the distribution of the center of mass as a function of the angular variation of the ankle in the elderly in the upright position.

详细描述

Usually the balance evaluation the center of mass displacement for the analysis of postural control is assessed by means of force platforms. However, most of these devices are stationary, that is the patient is the dynamic element which can generate an evaluation with high subjectivity index. Therefore, this study aimed at developed a reaction force to the ground platform which provides mechanical stimuli controlled to quantify the distribution of the mass center as a function of the angular variation in the elderly ankle in the upright position. The construction of the prototype was divided into 3 steps, based on the two-dimensional movement of the ankle joint. In the 1st stage the construction of the mechanical assembly; in the 2nd stage development of the electronics; and 3rd stage the development of the supervisory system (control system). The force plataform was evaluated following the engineering functional tests such as: characterization and calibration of the sensors, the definition of the transfer function and accuracy of tests of angular movements (+ 10 ° and -10 ° to the movements of inversion and eversion, + 15 and -15º to the movements of dorsiflexion and plantar flexion). For the tests with volunteers were selected 30 volunteers.

研究设计

研究类型
Interventional
分配方式
Non Randomized
干预模型
Parallel
主要目的
Diagnostic
盲法
None

入排标准

年龄范围
20 Years 至 85 Years(Adult, Older Adult)
性别
All
接受健康志愿者
是

入选标准

  • •We included in this study individuals male and female
  • •Age ranging from 20 to 85 years
  • •Asymptomatic individuals
  • •Must walk without the use of an attachment
  • •Do not present motor deficit that makes the study impossible

排除标准

  • •Decompensated congestive heart failure
  • •Neurological or neurological diseases that interfere with significant neuromotor
  • •Individuals who did not agree to participate in the study

研究组 & 干预措施

Group 1 (adult)

Experimental

Each volunteer stood on the platform. The duration of the tests was standardized at 10 seconds for each angulation variant of the test. The tilt variables occurred every 5 degrees oscillating in the two-dimensional movement of the ankle joint. The test was discontinued when the volunteer failed to remain balanced at the tested angulation for more than 10 seconds (thus shifting the foot (s) from the initial position or supporting with one and / or both arms at the therapist or at the support bars ) or when it reached maximum angulation

干预措施: Force plate (Device)

Group 2 (elderly)

Experimental

Each volunteer stood on the platform. The duration of the tests was standardized at 10 seconds for each angulation variant of the test. The tilt variables occurred every 5 degrees oscillating in the two-dimensional movement of the ankle joint. The test was discontinued when the volunteer failed to remain balanced at the tested angulation for more than 10 seconds (thus shifting the foot (s) from the initial position or supporting with one and / or both arms at the therapist or at the support bars ) or when it reached maximum angulation

干预措施: Force plate (Device)

结局指标

主要结局

Mass distribution

时间窗: 15 minutes

The center of mass was measured by the patient remaining on the force platform, remaining for 10 seconds in each angulation variant Unit of measurement: Kilograms (kg)

次要结局

未报告次要终点

研究者

申办方类型
Other
责任方
Principal Investigator
主要研究者

Leandro Lazzareschi

PhD

University of Mogi das Cruzes

相似试验