Assessment of the Learning Curve of Total Thoracoscopic Mitral Valve Repair Using Cumulative Sum Analysis (CUSUM)

Yunlong Fan1 个研究点 分布在 1 个国家目标入组 150 人开始时间: 2017年10月1日最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
发起方
入组人数
150
试验地点
1
主要终点
Cardiopulmonary bypass (CPB) time

研究概览

简要总结

Total thoracoscopic mitral valve plasty (MVP) is characterized by minimal trauma, minimal bleeding, and short postoperative recovery time. The learning curve of any new procedure needs to be evaluated for learning and replication.Using Cardiopulmonary bypass (CPB) time and Aortic clamping (AC) time as evaluation variables, we visualized the learning curve for total thoracoscopic MVP using Cumulative sum analysis. We also analyzed important postoperative variables such as postoperative drainage, duration of mechanical ventilation, ICU stay and postoperative hospital stay.

The retrospective study comprised 150 consecutive patients who underwent total thoracoscopic MVP from October 2017 to July 2021.

研究设计

研究类型
Observational
观察模型
Case Only
时间视角
Retrospective

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者
否

入选标准

  • •age over 18 years who underwent total thoracoscopic MVP without concurrent cardiac Surgery

排除标准

  • •data miss greater than 10%

结局指标

主要结局

Cardiopulmonary bypass (CPB) time

时间窗: Intra-operative

Cardiopulmonary bypass (CPB) time was used as the main variables for evaluation and visualization of the total thoracoscopic mitral valve plasty (MVP) learning curve using Cumulative sum.Cumulative sum (CUSUM) is a statistical method that focuses on results rather than on the process of performing a program skills, it generates graphs that allow for quick detection of deviations from pre-established standards and is an alternative tool that can be used to evaluate the performance of individual program. CUSUM can be generated based on set acceptable and unacceptable failure rates and the degree to which type 1(α) and type 2(β) errors (false positive and false negative errors) will be tolerated. CUSUM was defined as Sn = ∑(Xi -p0), where Xi = 0 for success and Xi = 1 for failure, p0 is the target reference.

Aortic clamping (AC) time

时间窗: Intra-operative

Aortic clamping (AC) time was used as the main variables for evaluation and visualization of the total thoracoscopic mitral valve plasty (MVP) learning curve using Cumulative sum.Cumulative sum (CUSUM) is a statistical method that focuses on results rather than on the process of performing a program skills, it generates graphs that allow for quick detection of deviations from pre-established standards and is an alternative tool that can be used to evaluate the performance of individual program. CUSUM can be generated based on set acceptable and unacceptable failure rates and the degree to which type 1(α) and type 2(β) errors (false positive and false negative errors) will be tolerated. CUSUM was defined as Sn = ∑(Xi -p0), where Xi = 0 for success and Xi = 1 for failure, p0 is the target reference.