MedPath

His Bundle Pacing Versus Coronary Sinus Pacing for Cardiac Resynchronization Therapy

Not Applicable
Completed
Conditions
Congestive Heart Failure
Interventions
Device: CRT Pacemaker
Registration Number
NCT02700425
Lead Sponsor
University of Chicago
Brief Summary

The goal of this study is to compare the effectiveness of pacing from a physiologic His bundle (HB) lead position versus with the standard coronary sinus (CS) lead position in subjects with heart failure undergoing cardiac resynchronization therapy (CRT). While placement of left ventricular leads via the coronary sinus has anatomic limitations, we hypothesis that the achievement of QRS narrowing with His bundle capture will be superior for improving systolic function by echocardiographic indices (ejection fraction and strain) and quality of life and decreased rehospitalization and mortality.

Detailed Description

This is a randomized, single-blinded study of 40 patients to a strategy of HB pacing versus CS pacing, and remain blinded to their treatment allocation. Both treatment options use standard-of-care, FDA-approved devices. The distinction is only in the allocation toward HB pacing and CS pacing. Treating physicians will be aware of assignment in order to facilitate routine device follow-up. Echocardiographic and electrocardiographic evaluation will also be performed in a blinded manner.

Cross-over is permitted between treatment group allocation if:

* CS lead cannot be placed due to difficult cannulation of the CS, limited branches at the posterolateral or lateral wall, or phrenic nerve capture. These subjects may then cross-over to HB pacing.

* HB pacing subjects may cross-over if HB lead cannot be positioned with adequate stability and reasonable pacing output, or if QRS width does not narrow by at least 20% or to a QRS width of ≤ 130 msec.

Implant procedure will be per routine percutaneous access, as is standard for pacemaker and ICDs. All subjects will receive an FDA-approved cardiac resynchronization therapy pacemaker or defibrillator device, as per standard of care outlined for the subject. In order to facilitate optimal lead placement, arterial access for levo-phase CS angiography and/or LV septal mapping to characterize site of bundle-branch block may also be performed, at the discretion of the implanting physician per his/her standard practice.

Follow-up will be performed at 2 weeks post-implant for incision check and device interrogation as is standard of care. In addition, routine device and clinical follow-up will be scheduled at 1, 3, 6, and 12 months. Electrocardiography (ECG) will be performed pre-implant, prior to hospital discharge, at 3 months, 6 months, and 12 months. Echocardiography will be performed pre-implant and 6 months to evaluate for change in LVEF, chamber dimension, and wall motion with strain imaging as is standard of care in the treatment of patients with advanced heart failure. NYHA functional class and quality of life (utilizing the Kansas City Cardiomyopathy Questionnaire) will be assessed pre-implant and at 6 months.

Recruitment & Eligibility

Status
COMPLETED
Sex
All
Target Recruitment
41
Inclusion Criteria
  • Patients at least 18 years of age
  • LV systolic dysfunction with LVEF ≤ 35%
  • Evidence of intraventricular conduction delay with QRS duration > 120 msec
  • NYHA Class II, III, and ambulatory Class IV heart failure with either ischemic or nonischemic cardiomyopathy and patients with NYHA Class I symptoms and ischemic cardiomyopathy
  • Left ventricular ejection fraction (LVEF) ≤ 35%, sinus rhythm (SR), left bundle-branch block (LBBB) morphology, and QRS duration ≥ 150 msec, and NYHA Class II, III, or ambulatory Class IV patients on goal-directed medical therapy (GDMT) [Class I]
  • LVEF ≤ 35%, SR with LBBB with QRS 120-149 msec on GDMT [Class IIa]
  • LVEF ≤ 35%, SR with non-LBBB with QRS ≥ 150 msec on GDMT [Class IIa]
  • LVEF ≤ 35%, in AF if medication or AV nodal ablation will allow near 100% pacing [Class IIa]
  • LVEF ≤ 35% undergoing new or replacement device with anticipated >40% ventricular pacing on GDMT [Class IIa]
  • LVEF ≤ 30%, ischemic etiology of HF, SR with LBBB ≥ 150 msec and NYHA Class I symptoms on GDMT [Class IIb]
  • LVEF ≤ 35%, SR with non-LBBB with QRS 120-149 msec, NYHA Class III/ambulatory Class IV HF on GDMT [Class IIb] LVEF ≤ 35%, SR with non-LBBB with QRS ≥ 150 msec, NYHA Class II HF on GDMT [Class IIb]
Read More
Exclusion Criteria
  • Existing CRT device
  • Inability of patient capacity to provide consent for themselves either due to medical or psychiatric comorbidity
  • Pregnancy
  • Participation in other trials
  • Difficulty with follow-up
Read More

Study & Design

Study Type
INTERVENTIONAL
Study Design
PARALLEL
Arm && Interventions
GroupInterventionDescription
His Bundle PacingCRT PacemakerSubjects will be randomized to the HB lead position with their cardiac resynchronization therapy (CRT) pacemaker. HB lead pacing will be performed with the Medtronic SelectSecure™, Model 3830 lead. Delivery of the lead utilizes a deflectable sheath, the Medtronic SelectSite™, Model C304. Both devices are FDA approved for the purpose of HB pacing. It is the only device available which is presently FDA approved for selective HB pacing.
Coronary Sinus PacingCRT PacemakerSubjects will be randomized to the CS lead position with their cardiac resynchronization therapy (CRT) pacemaker. CS lead and CRT device generator selected for implant will be left to the discretion of the operator. Only FDA approved CS leads and CRT generators will be utilized in the study. There are five present manufacturers of CS leads and CRT generators: Biotronik, Boston Scientific, Medtronic, Sorin, and St. Jude Medical.
Primary Outcome Measures
NameTimeMethod
Change in QRS Durationbaseline and 12 months

Change in QRS duration as measured by electrocardiography

Change in Left Ventricular Ejection Fraction (LVEF)baseline and 6 months

Change in left ventricular ejection fraction (LVEF) as measured by echocardiography in a blinded core lab.

Time to First Cardiovascular Hospitalization or DeathThrough study completion, an average of 12 months.

Time to first cardiovascular hospitalization or death in months

Secondary Outcome Measures
NameTimeMethod
Time to First Cardiovascular RehospitalizationThrough study completion, an average of 12 months

Time to first cardiovascular rehospitalization in 12 months

Time to First Treated Ventricular Arrhythmia/Ventricular Tachycardia (VT/VF)Through study completion, an average of 12 months

Time to first treated ventricular arrhythmia/ventricular tachycardia (VT/VF) in 12 months

Quality of Life Change by Kansas City Questionnaire (KCCQ)baseline and 12 months

Quality of life change as measured by Kansas City Questionnaire (KCCQ) is a 23-item instrument that is self-administered. KCCQ measures physical function, symptoms (specifically frequency, severity, and recent change), social function, self-efficacy and knowledge, and quality of life. Subscales and Total Score range from minimum of 0-100 (maximum); higher scores show better health status. Developed and validated by Dr. John Spertus,MD of University of Missouri-Kansas City.

New York Heart Association (NYHA) Functional Class Changebaseline, 6 months, and 12 months

New York Heart Association (NYHA) functional class change for baseline, 6 months, and 12 months. NYHA class determines the functional status of the patient. There are classes I-IV. Class I is no symptoms or limitation of physical activity, II is slight limitation of physical activity but comfortable at rest, III marked limitation of physical activity, and IV is unable to carry any physical activity without discomfort, heart failure symptoms at rest, and discomfort increases with any physical activity as described the American Heart Association (AHA).

Trial Locations

Locations (8)

Edward Hospital

🇺🇸

Naperville, Illinois, United States

Baptist Health Louisville

🇺🇸

Louisville, Kentucky, United States

Northwestern University

🇺🇸

Chicago, Illinois, United States

Rush University Medical Center

🇺🇸

Chicago, Illinois, United States

Indiana University

🇺🇸

Indianapolis, Indiana, United States

The University of California, Los Angeles

🇺🇸

Los Angeles, California, United States

Geisinger Wyoming Valley Medical Center

🇺🇸

Wilkes-Barre, Pennsylvania, United States

The University of Chicago

🇺🇸

Chicago, Illinois, United States

© Copyright 2025. All Rights Reserved by MedPath