Validity, Reliability, and Clinical Correlates of Immersive Virtual Reality Adaptation of the Five Times Sit-to-stand Test and Timed up and go Tests in Women With Fibromyalgia Syndrome
试验速览
- 阶段
- 不适用
- 状态
- 尚未招募
- 入组人数
- 51
- 主要终点
- Performans evaluation
研究概览
简要总结
Fibromyalgia syndrome (FMS) is a chronic rheumatic condition characterized by widespread pain, fatigue, and functional impairments that negatively affect physical activity levels, muscle strength, balance, and functional mobility. These impairments may lead to reduced functional capacity and increased sedentary behavior. Therefore, objective assessment of mobility, balance, and functional performance is essential in individuals with FMS.
Performance-based tests such as the Five Times Sit-to-Stand Test (5xSTS) and the Timed Up and Go (TUG) test are commonly used to evaluate lower extremity muscle function, balance, and functional mobility due to their simplicity, feasibility, and clinical relevance. Recently, virtual reality (VR)-based assessment methods have emerged as a standardized and objective approach for evaluating functional performance.
This study aims to investigate the feasibility and measurement properties of virtual reality-based adaptations of the 5xSTS and TUG tests in individuals with fibromyalgia syndrome using a head-mounted VR system. Findings from this study are expected to contribute to the clinical use of VR technology in mobility and balance assessment in individuals with FMS.
研究设计
- 研究类型
- Observational
- 观察模型
- Other
- 时间视角
- Prospective
入排标准
- 年龄范围
- 30 Years 至 60 Years(Adult)
- 性别
- Female
- 接受健康志愿者
- 否
入选标准
- •• Having been diagnosed with FMS according to the American Rheumatology Association (ARB) 1990 classification criteria,
- •Being female between the ages of 30-60
- •Having the cognitive ability to understand the instructions
- •Being a volunteer
排除标准
- •• Severe physical disability
- •Rheumatological/neurological diseases
- •Any musculoskeletal problem (fracture, deformity, sprain)
- •Malignancy
- •Severe cognitive impairment
- •Pregnancy
结局指标
主要结局
Performans evaluation
时间窗: Baseline and 7 days later (test-retest interval).
Performance outcomes will be assessed using the Five Times Sit-to-Stand Test (5xSTS) and the Timed Up and Go (TUG) test. These tests are widely used functional performance measures with established validity and reliability. In this study, virtual reality (VR) adaptations of both tests will also be applied. Participants will enter the testing environment using a VR headset, and test protocols will be conducted in the same manner as the conventional applications. The VR-based assessments will follow standardized procedures equivalent to the traditional versions of the 5xSTS and TUG tests.
次要结局
- Hand Grip Strength(Baseline)
- Knee extension muscle strength(baseline)
- Physical Activity Level(baseline)
- Single-Leg Balance Test Time(baseline)
研究者
Zehra KORKUT
Principal Investigator
Selcuk University
