Novel Modified Technique for Transcatheter Closure of Secundum Atrial Septal Defect: A Single Center Experience
Overview
- Phase
- Not Applicable
- Intervention
- Not specified
- Conditions
- Atrial Septal Defect (ASD)
- Sponsor
- Egyptian Biomedical Research Network
- Enrollment
- 80
- Locations
- 1
- Primary Endpoint
- recording any complication during transcatheter secundum atrial septal defect closure
- Status
- Completed
- Last Updated
- last year
Overview
Brief Summary
Transcatheter closure of secundum atrial septal defects is widely approved worldwide, yet it still has multiple risks like perforation and radiation exposure. In this study, we proposed a modified rapid method for closure of secundum atrial septal defects, to avoid material manipulation inside your heart and decrease complication rate.
Detailed Description
Delivery sheath can be advanced over multipurpose catheter instead of stiff wire
Investigators
Nouran Mostafa Mansour
dr
Egyptian Biomedical Research Network
Eligibility Criteria
Inclusion Criteria
- •Any patient with ostium secundum ASD \& RV volume overload
Exclusion Criteria
- •Any other type of atrial septal defects Any other associated congenital anomaly
Outcomes
Primary Outcomes
recording any complication during transcatheter secundum atrial septal defect closure
Time Frame: during the procedure
stiff wire can cause perforation or arrhythmias
Secondary Outcomes
- assess the duration of the procedure and if this affects the cost of the procedure by any means(during the procedure)