22-gauge ProCore Needle v. Standard 22-gauge (P00030500)
- Conditions
- Quality of Tissue ObtainedQuantity of Tissue ObtainedEase of Use of 22-gauge ProCore EBUS Needles and the Standard 22-gauge Needles
- Interventions
- Other: 22-gauge ProCore NeedleOther: 22-gauge Standard Needle
- Registration Number
- NCT02154698
- Lead Sponsor
- Medical University of South Carolina
- Brief Summary
The purpose of this study is to compare the usefulness of two needles (used for obtaining a lung tissue sample : (1) standard 22-gauge, and (2) ProCore 22-gauge) for endobronchial ultrasound
- Detailed Description
The purpose of this study is to compare the usefulness of two needles used for obtaining a lung tissue sample: (1) standard 22-gauge, and (2) ProCore 22-gauge. Both of these needles are used to get biopsies (samples) of lung tissue. The standard needle has one bevel (angled side of the needle formed when it is sharpened to make a point), while the ProCore needle has 2 bevels. The standard needle is more commonly used and we are doing this study to see if the ProCore needle would be more useful.
The investigator in charge of this study is Dr. Nichole T. Tanner. This study is being done at four sites and will involve approximately 200 volunteers.
Recruitment & Eligibility
- Status
- COMPLETED
- Sex
- All
- Target Recruitment
- 200
- Subjects with known or suspected lung cancer with mediastinal adenopathy as defined by a mediastinal lymph node >1 cm in short axis or a normal sized lymph node with uptake on FDG-PET scan that is higher than background PET activity.
- Participants must be at least 18 years old or older, lack bleeding disorders, and be able to provide informed consent. The latter two criteria will be assessed from the patient's history and the consenting interview.
- Subjects who refuse to participate, or demonstrate inability to give informed consent
- Subjects who are less than 18 years of age
- Subjects who lack fitness for flexible bronchoscopy as determined by the physician performing the bronchoscopy before the procedure
- Subjects with suspected sarcoidosis, lymphoma, or metastatic cancer from other sites (i.e. those without a known or suspected lung primary)
- Subjects on anticoagulation (other than Aspirin) whom cannot have their anticoagulation held for the procedure due to other clinical reasons (i.e. recent cardiac stent placement).
Study & Design
- Study Type
- INTERVENTIONAL
- Study Design
- PARALLEL
- Arm && Interventions
Group Intervention Description 22-gauge ProCore Needle 22-gauge ProCore Needle Participants will have each node sampled starting with the ProCore 22G on the first pass followed by the standard 22G needle on the second pass (for a total of 8 passes) 22-gauge Standard Needle 22-gauge Standard Needle Participants will have each node sampled starting with the standard 22G needle on the first pass followed by the ProCore 22G needle on the second pass (for a total of 8 passes)
- Primary Outcome Measures
Name Time Method Quality of tumor obtained (measured by cell block and ability to perform mutational analysis) Within two weeks from the day of the procedure Ease of use of 22-gauge ProCore EBUS needles and the standard 22-gauge needles. Within two weeks from the day of the procedure Quantity of tissue obtained (measured by number of unstructured fragments) Within two weeks from the day of the procedure
- Secondary Outcome Measures
Name Time Method
Trial Locations
- Locations (4)
University of Florida
🇺🇸Gainesville, Florida, United States
Johns Hopkins University
🇺🇸Baltimore, Maryland, United States
University of North Carolina Medical School
🇺🇸Chapel Hill, North Carolina, United States
Medical University of South Carolina
🇺🇸Charleston, South Carolina, United States