MedPath

Penile Lengthening Pre-Penile Prosthesis Implantation

Not Applicable
Recruiting
Conditions
Erectile Dysfunction
Registration Number
NCT07053826
Lead Sponsor
University of Pittsburgh
Brief Summary

The goal of this study is to determine whether or not the use of a penile traction therapy device known as RestoreX prior to implantation of a penile prosthesis can increase the length of the implant used during surgery. The device used in this study is commercially available and has been used successfully to facilitate penile lengthening in patients with diabetes and after a certain type of prostate surgery. Use of the device has not been shown to have any detrimental effects on sexual or overall health.

Detailed Description

Men with erectile dysfunction (ED) refractory to medical therapies are often recommended to undergo placement of an inflatable penile prosthesis (IPP). However, men commonly report a perceived loss of penile length following IPP implantation. This is likely due to one of several factors, including the underlying disease process which resulted in loss of penile length, effects of aging on penile length (loss of elasticity; increased fibrosis), changes in abdominal physiology (development of pre-pubic fat pad that obscures the penis), and recall bias (incorrect recollection of prior penile length).

Several attempts have been made by investigators to optimize penile length prior to placement of the penile prosthesis, including adjunctive surgical maneuvers (excision of suprapubic fat pad, release of suspensory ligament, direct penile extension), use of injectable materials, and pre-operative use of penile traction therapy (PTT). In a small pilot study of 10 men undergoing IPP, Levine and colleagues recommended the use of the Andropenis PTT ≥2 hrs daily for 2-4 months. At 15 months follow-up, patients achieved a +1.6 cm increase compared to pre-traction stretched length, and +0.9 cm increase following prosthesis implantation. Results from a non-validated satisfaction questionnaire demonstrated that no patients reported loss of length following surgery. Unfortunately, the study did not include a control group, thus limiting the conclusions which may be drawn.

Compared to other options, PTT offers several potential advantages in that it is minimally invasive, does not increase the morbidity of surgery, and has not been shown to result in any long-term side effects. RestoreX is a commercially available PTT device that was developed by the Mayo clinic and has been licensed to PathRight Medical. It has been designated as a Class I device that does not require clinical human trials. The device is currently utilized in 30-minute intervals, with up to 3 sessions performed per day, and has demonstrated efficacy at increasing stretched penile length in patients with postprostatectomy penile shortening and diabetes mellitus.

Given the clinical issue of dissatisfaction with penile length post IPP, the potential role for PTT, and the limited amount of data that are currently available, we seek to perform a clinical trial evaluating the effect of PTT stretched penile length, size of prosthetic implantation at time of surgery, and patient satisfaction following implantation.

The device has two functional aspects. The first is the ability to provide direct traction on the penis. The second is the ability to provide counter-bending forces, to treat conditions such as Peyronie's disease. In the current study, only the direct traction aspects of the device will be investigated. Men randomized to treatment will be recommended to utilize the device for 30 minutes, 3 times daily for 3 months prior to placement of an IPP, with up to 1.3 additional months to account for variability in surgical timing.

To date, the efficacy of the RestoreX device has been studied in multiple clinical trials, the results of which are briefly outlined below:

* In a randomized, controlled clinical trial, 82 men who underwent prostatectomy for prostate cancer revealed an average increase in stretched penile length of 1.6 cm after 5 months of RestoreX use vs no change for controls (P=0.001). Adverse events were transient and mild, with 87% of men reporting a desire to repeat therapy and 93% of participants reporting that they would recommend it to others.

* In the open-label phase of the study, the benefits of therapy were found to be maintained even after therapy was discontinued.

* In a randomized, single-blind, controlled trial, 110 men with Peyronie's disease were assigned 3:1 to penile traction therapy for three months vs no therapy. At three months, penile traction therapy was associated with a 1.5 cm increase in penile length and 11.7 degree reduction in penile curvature relative to controls. Further, erectile function scores improved 4.3 points relative to a loss of 0.7 points in the control group. The therapy was well tolerated; adverse events were transient and mild.

* Preliminary data also suggest that the RestoreX device can increase penile length on men with diabetes who did not undergo surgery.

Very limited data are available on the efficacy of PTT in men undergoing placement of an IPP. As noted above, a small pilot study of 10 men undergoing IPP demonstrated a +1.6 cm increase in penile length compared to pre-traction stretched length and 0% of men reporting loss of length following surgery.

Recruitment & Eligibility

Status
RECRUITING
Sex
Male
Target Recruitment
48
Inclusion Criteria
  • Have a documented diagnosis of erectile dysfunction
  • Can provide informed consent
  • Are willing and able to comply with study procedures and visit schedules
  • Are to be scheduled for a planned standard of care implantation of an inflatable penile prosthesis
Exclusion Criteria
  • Prior ischemic priapism
  • Prior implantation of a penile prosthesis
  • Prior use of any penile traction device
  • Any prior penile surgeries other than circumcision
  • Prior pelvic radiation
  • Current or prior androgen deprivation therapy
  • Active genital infection
  • History of neophallus creation

Study & Design

Study Type
INTERVENTIONAL
Study Design
PARALLEL
Primary Outcome Measures
NameTimeMethod
Penile LengthAt screening to approximately three months after enrollment at the time of penile prosthesis implantation

Change in stretched penile length measured at time of enrollment and intraoperatively at the time of IPP implantation, measured in cm.

Prosthesis size0-4 months after enrollment at the time of penile prosthesis implantation

Size of inflatable penile prosthesis cylinders placed

Sexual SatisfactionAt enrollment and at three-month postoperative follow up.

Change in patient-reported satisfaction with their sexual function from enrollment to final postoperative follow up using the validated IIEF-15 (International Index of Erectile function - 15 item) questionnaire, which has a minimum score of 6 and maximum score of 75 with a larger number indicating improved sexual satisfaction. The change seen in participants assigned to the RestoreX device arm will be compared to the change seen in patients assigned to the control arm.

Incidence of Satisfaction with Penile Length3-8 months postoperatively

A comparison of the incidence of participants reporting satisfaction with their penile length, expressed as a percentage or all participants within each group, based on participant reporting to an investigator during their surgical follow up.

Secondary Outcome Measures
NameTimeMethod
Compliance with Therapy0-4 months after enrollment, intervention arm only

Patient compliance with traction device regimen using a device use diary will be assessed. Compliance will be reported as a percentage of recommended use sessions completed.

Incidence of adverse events0-16 months

The incidence of all adverse events arising from penile traction therapy device use or inflatable penile prosthesis placement will be monitored throughout the study during in-person encounters and via chart review at the conclusion of the study.

Patient Satisfaction with Prosthesis Use3-8 months

Patients randomized to RestoreX device use prior to prosthesis placement will be asked if they would use a penile traction device again, and how satisfied they were, on surveys administered immediately prior to, and three months following, prosthesis placement using Likert-style questions.

Trial Locations

Locations (1)

UPMC Mercy Hospital, Urology

🇺🇸

Pittsburgh, Pennsylvania, United States

UPMC Mercy Hospital, Urology
🇺🇸Pittsburgh, Pennsylvania, United States
Michelle Lucas, MS
Contact
412-624-4708
mcmeansmm2@upmc.edu
Eleanor Shirley, MA, CCRC
Contact
shirleye@upmc.edu

MedPath

Empowering clinical research with data-driven insights and AI-powered tools.

© 2025 MedPath, Inc. All rights reserved.