跳至主要内容
临床试验/NCT05409898
NCT05409898Unknown不适用

Screening for Masked Hypertension in Young and Middle-aged Adults With Smart Wearable Devices (SMART)

Jing Liu1 个研究点 分布在 1 个国家目标入组 200 人开始时间: 2022年7月最近更新:
适应症

试验速览

阶段
不适用
发起方
入组人数
200
试验地点
1
主要终点
Prevalence of masked hypertension

研究概览

简要总结

In recent years, a large number of consumer-grade and Smart Wearable Devices (SWD) such as smart watches, with BP measurement property, have entered the market and have a high configuration and utilization among young and middle-aged populations, but most of them are uncalibrated and have poor accuracy. Recently, several medical-grade smart BP watches have passed the national medical device registration test, which will provide an important tool for accurate screening of hypertension, especially masked hypertension, in young and middle-aged people.

"Screening for masked hypertension in young and middle-aged adults with smart wearable devices" (SMART)aims to screen for masked hypertension using smart BP watches that have been tested for national medical device registration. It is planned to include 200 young and middle-aged subjects with normal blood pressure (BP) in the clinic, who will wear the smart BP watch for 7 consecutive days (BP will be measured at least once in the morning and once in the evening, 2-3 times each time), and if the mean BP is >= 135/85 mmHg, it will be determined to be MK and recommended for further consultation and treatment.

详细描述

Masked hypertension (MH) is defined as elevated ambulatory or home blood pressure (BP), but normal office BP, often complicated with severe cardiovascular and renal damage. MH is easily missed and needs to be identified by "out-of-office" BP measurements such as ambulatory BP monitoring (ABPM) or home BP monitoring (HBPM). However, in clinical practice, ABPM has poor accessibility, high cost, and requires appointments, making it difficult to meet the demand; HBPM has better accessibility, but low utilization and irregular use are more prominent. In addition, these devices interfere with sleep and activity when measuring BP, so their clinical application is somewhat limited.

Smart wearable devices (SWD) can sense and record various physiological parameters of human body, and analyze the health status of individuals with the support of software algorithms. In recent years, a large number of consumer-grade and SWD such as smart watches, with BP measurement property, have entered the market and have a high configuration and utilization among young and middle-aged populations, but most of them are uncalibrated and have poor accuracy. Recently, several medical-grade smart BP watches have passed the national medical device registration test, which will provide an important tool for accurate screening of hypertension, especially MH, in young and middle-aged people.

"Screening for masked hypertension in young and middle-aged adults with smart wearable devices" (SMART) aims to screen for MH using smart BP watches that have been tested for national medical device registration. It is planned to include 200 young and middle-aged subjects with normal blood pressure in the clinic, who will wear the smart BP watch for 7 consecutive days (BP will be measured at least once in the morning and once in the evening, 2-3 times each time), and if the mean BP is >= 135/85 mmHg, it will be determined to be MK and recommended for further consultation and treatment.

研究设计

研究类型
Observational
观察模型
Cohort
时间视角
Prospective

入排标准

年龄范围
18 Years 至 50 Years(Adult)
性别
All
接受健康志愿者

入选标准

  • 18-50 years of age, male or female
  • No clear previous history of hypertension and other cardiovascular diseases
  • Signed informed consent form

排除标准

  • Patients with established hypertension
  • History of severe heart, liver, or kidney disease
  • Inability to cooperate in completing the study

结局指标

主要结局

Prevalence of masked hypertension

时间窗: 7 days

Average systolic/diastolic BP during 7 days of the observation period will be calculated. Office BP should be measured when the average BP is ≥135/85 mmHg during 7 days of continuous self-monitoring. If the office BP is \< 140/90 mmHg at visit, "Masked Hypertension" will be diagnosed. The prevalence of masked hypertension will be calculated as the following: number of masked hypertension/number of subjects included.

次要结局

  • Prevalence of hypertension(7 days)

研究者

发起方
Jing Liu
申办方类型
Other
责任方
Sponsor Investigator
主要研究者

Jing Liu

Director of the Department of Hypertension

Peking University People's Hospital

研究点 (1)

Loading locations...

相似试验