Clinical Outcomes of Different Staged Ridge-Splitting Techniques Using Piezo-Electric Surgery in Atrophic Posterior Mandible
试验速览
- 阶段
- 不适用
- 状态
- 已完成
- 入组人数
- 18
- 试验地点
- 2
- 主要终点
- Alveolar ridge width
研究概览
简要总结
This study aims to evaluate the clinical and radiographic outcomes of different staged ridge-splitting techniques for management of severely resorbed lower jaws in the posterior region. The study is designed as a clinical trial, so that three different interventions would be compared for a conclusion highlighting the relative best of them.
详细描述
In the context of the care of severely resorbed lower jaws in the posterior region, the purpose of this study is to evaluate the clinical and radiographic outcomes of several stepwise ridge-splitting procedures. The study is supposed to be a clinical trial, with the purpose of comparing three distinct therapies in order to get a result that highlights which of them is the most effective in comparison to the others.
研究设计
- 研究类型
- Interventional
- 分配方式
- Randomized
- 干预模型
- Parallel
- 主要目的
- Treatment
- 盲法
- None
入排标准
- 年龄范围
- 25 Years 至 50 Years(Adult)
- 性别
- All
- 接受健康志愿者
- 是
入选标准
- •Patients were free from any relevant systemic diseases according to American society of Anesthesiologists classifications.
- •Patients of single or multiple missing teeth in the posterior mandible.
- •A ridge width of minimum 4mm and a 10 mm ridge height with 2mm minimum above Inferior Alveolar Nerve (IAN) were present in CBCT images.
- •Absence of buccal concavities at the planned implant site.
排除标准
- •History of any systemic diseases or medication that alters bone metabolism.
- •Poor oral hygiene.
- •Heavy smoker (more than 20 cigarettes/day) or alcoholic patients.
- •Chemotherapy or radiation therapy to the head and neck region in the last 12 months prior to the proposed implant therapy.
- •Patients currently on or with a history of bisphosphonate therapy.
结局指标
主要结局
Alveolar ridge width
时间窗: immediately after implant placement, immediately after implant loading and six months after implant loading
Radiographically via Cone-beam Computed Tomography (CBCT), the width of the alveolar bone was measured horizontally from the buccal to lingual cortex below the crest of the alveolar bone from 3 levels at 1 mm, 3 mm and 6 mm on three cross-sections by the CBCT software (OnDemand, Cybermed Inc, Korea).
次要结局
- Implant stability(immediately after implant placement, immediately after implant loading and six months after implant loading)