Brief Summary

The goal of this clinical trial is to develop and validate of a new protocol for multifactorial functional assessment of the kinematics of spinal and total body movements during walking by means of the optoelectronic motion analysis system in healthy and scoliosis subjects.

The main questions it aims to answer are:

* Is feasibility developing a protocol to assess the spine kinematic during walking?

* Is the intra and inter operator reliability of the developed protocol acceptable?

* Is the usability of the developed protocol acceptable? During data acquisition a trained therapist placed reflective markers on the skin of the participants in the selected body landmarks. The participants will be asked to perform five trial of walking barefoot on a 6 meters distance at a self-selected normal-pace speed, for each session.

Detailed Description

The spine is the central supporting structure of the body and for the torso in particular, allowing for flexibility and shock absorption, as well as routing and protecting the spinal cord and supporting the head and upper limbs for sensory and motor functions. In this perspective the evaluation of its movements in a global and segmental contribution is of paramount importance and cannot be separated by the other tasks. The locomotor function was the first one targeted by human motion analysis and still represent the main application in the rehabilitation. Optoelectronic systems are the gold standard technique for this assessment and specific protocols are available and applied. Traditional stereophotogrammetric models were used to assess the kinematics of pelvis, hip, knee, ankle, trunk (considered as a single rigid segment that does not provide information on kinematic changes within the spine). Indeed, it is relevant to understand the integrated and synergic motion of the spine and other body segment for a variety of applications, such as clinical diagnosis, endoprosthesis design, and the evaluation of treatment outcomes. Therefore, an accurate trunk motion analysis may be useful during medical diagnostic-therapeutic process. The aim of this study is introducing a new protocol consisting of a marker set, i.e. an innovative and integrated biomechanical model of the human body for the global analysis of spine and body movement during gait allows for a more detailed evaluation of the motor behavior and its abnormalities to better characterize the functionality of the spine at the level of its three main segments (upper thoracic, lower thoracic and lumbar), both on the sagittal, frontal and transversal plane, during walking. The development of a new protocol of analysis requires the validation before its definitive and clinical application. More in detail, the validation should be carried out in terms of both comparisons with reference absolute measures and the evaluation of its repeatability with healthy subjects.

Recruitment & Eligibility

Status
RECRUITING
Sex
All
Target Recruitment
20
Inclusion Criteria
  • no history of low back pain or spine related pathology
Exclusion Criteria
  • motor impairments during gait

For scoliosis group:

Inclusion Criteria:

  • Diagnosis of idiopathic scoliosis
  • Autonomous gait

Exclusion Criteria:

  • motor impairments during gait

Study & Design

Study Type
INTERVENTIONAL
Study Design
PARALLEL
Arm && Interventions
GroupInterventionDescription
Healthy subjectsSpine Kinematic Assessment with Optoelectronic systemSubjects without spine disease
Scoliotic subjectsSpine Kinematic Assessment with Optoelectronic systemSubjects with a scoliosis diagnosis
Primary Outcome Measures
NameTimeMethod
Intra/Inter Operator ReliabilityThrough study completion, an average of 3 year

In the intra and interoperator repeatability analysis the investigators considered the correlation coefficient for the average RoM (in the 5 trials) in corresponding sessions. In particular, the investigators referred to standard interpretation criteria: the ICC values 0.5 and 0.75 indicate moderate reliability, values between 0.75 and 0.9 indicate good reliability, and values greater than, 0.90 indicate excellent reliability.

Intra and inter operator reliability will be calculated at the achievement of ten healthy subjects ( during the first year), and then at the achievement of ten scoliotic subjects (during the second year)

SUS questionnaire score for usability assessmentThrough study completion, an average of 3 year

About the usability assessment, the System Usability Scale (SUS) collected at the end of each acquisition and calculated the average score value. The SUS provides a reliable tool for measuring the usability. The SUS questionnaire consists of a 10 item questionnaire with five response options for respondents; from Strongly agree to Strongly disagree

Root mean square error as measure of accuracyYear 1

For the accuracy analysis, the comparison between the reference measures and the measure obtained with the optoelectronic system for every segment of the spine assessed through the root mean square error

Secondary Outcome Measures
NameTimeMethod