跳至主要内容
临床试验/NCT04134975
NCT04134975已完成不适用

Evaluation of the Contribution of Intraoperative Scans Coupled With the Navigation for the Precision of the Positioning of the Pedicle Screws During a Lumbar Spine Surgery: a Prospective Randomised Study ScanRach Study

GCS Ramsay Santé pour l'Enseignement et la Recherche2 个研究点 分布在 1 个国家目标入组 126 人开始时间: 2018年10月16日最近更新:
适应症
干预措施

试验速览

阶段
不适用
状态
已完成
入组人数
126
试验地点
2
主要终点
pedicle screw positioning

研究概览

简要总结

Investigators team propose to evaluate the impact of the use of intraoperative scanning coupled with Stryker navigation, compared to the conventional fluoroscopy technique, on the accuracy of pedicle screws, in instrumented spinal surgery, by a randomised prospective study, in terms of pedicular screw accuracy. We will also evaluate the radiation exposure of the neurosurgical team and the patient in these two techniques.

详细描述

The use of pedicle screws in spinal surgery has seen a major advance in recent decades, allowing for greater biomechanical stability and higher fusion rates. In order to avoid any malposition that could cause neurological, vascular and visceral injuries and compromise this mechanical stability, imaging-guided surgical techniques have been developed. These are aimed at improving the positioning accuracy of pedicle screws to reduce these risks and improve mechanical stability and intervertebral fusion. Fluoroscopic examinations had long been the mainstay of intraoperative control imaging until the development of computer-assisted techniques. However, despite intraoperative examination, pedicle screw misalignment remains very common and even experienced surgeons can deviate screws in 5 to 20% of cases when using a standard fluoroscopic examination image. Thus, navigation techniques coupled with an intraoperative scanner, involving the acquisition of 2D images of the surgical field, have been developed. These techniques allow the neurosurgeon to navigate the spine and thus allow an improvement in the positioning accuracy of the pedicle screws. The correlate is an improvement of the safety of the procedure (reduction of complications) but also an optimisation of the biomechanical efficiency of the osteosynthesis.

With respect to the radiation emitted during navigated spinal surgery coupled with an intraoperative scan, some comparative studies have shown that the radiation rates received by the neurosurgical team and the patient were lower than the radiation rates received in conventional surgery. To date, few studies combining the analysis of the pedicular screw accuracy rate and the radiation rate transmitted to the neurosurgical team and patients have been published.

Therefore the team propose to evaluate the impact of the use of intraoperative scanning (BODYTom, Samsung) coupled with Stryker navigation, compared to the conventional fluoroscopy technique, on the accuracy of pedicle screws, in instrumented spinal surgery, by a randomised prospective study, in terms of pedicular screw accuracy. The investigator team will also evaluate the radiation exposure of the neurosurgical team and the patient in these two techniques.

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Parallel
主要目的
Other
盲法
None

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Male or female subject over the age of 18
  • Subject with lumbar degenerative pathology, requiring surgery with pedicle screw placement between L1 and S1, confirmed on MRI or preoperative scan
  • Well conducted medical treatment, at least 3 months, which did not allow pain sedation
  • Unprotected adult within the meaning of the law
  • Subject belonging to a health insurance scheme
  • Subject having signed their written informed consent.

排除标准

  • Subject who is a minor, pregnant, parturient or breastfeeding woman
  • Adult subject under legal protection, guardianship or deprivation of liberty by judicial or administrative decision
  • Subject hospitalised without consent
  • Medical contraindications to surgery and anaesthesia
  • Contraindication of a medical nature to an MRI (pace-maker) or a scan being carried out
  • Subject already treated by surgery for the same vertebral levels or adjacent levels
  • Subject with scoliosis with a Cobb angle of more than 10°.

研究组 & 干预措施

fluoroscopy group

Active Comparator

lumbar spinal surgery with pedicle screw placement guided by fluoroscopy, a fluoroscopic control being performed with each set screw.

干预措施: Spine surgery (Procedure)

Scanner Group

Experimental

lumbar spine surgical procedure with guided pedicle screw placement coupled with intraoperative scanning (BODYTOM, Samsung).

干预措施: Spine surgery (Procedure)

结局指标

主要结局

pedicle screw positioning

时间窗: 48 hours

The accuracy of pedicle screw positioning will be evaluated on the early postoperative examination scan (within 48 hours after the intervention) and graded according to the following classification: * correctly positioned: pedicle screws perfectly positioned in the pedicle or with a deflection of less than 4mm. * poorly positioned: pedicle screws with a deflection greater than 4 mm.

次要结局

未报告次要终点

研究者

申办方类型
Other
责任方
Sponsor

研究点 (2)

Loading locations...

相似试验