跳至主要内容
临床试验/NCT02393313
NCT02393313Unknown不适用

Examination of Rayner T-flex Toric Intra-Ocular Lens for Spherical and Astigmatic Correction, and Rotational Stability

Tel-Aviv Sourasky Medical Center2 个研究点 分布在 1 个国家目标入组 50 人开始时间: 2015年4月最近更新:
适应症

试验速览

阶段
不适用
入组人数
50
试验地点
2
主要终点
IOL off-axis rotation

研究概览

简要总结

This study evaluates the Rayner T-flex Toric IOLs for spherical and astigmatic correction, and rotational stability in cataract surgery. 50 patients with cataract and corneal astigmatism >= 2 diopters will undergo cataract surgery, with implantation of Rayner toric intraocular lens. Post-operative examination will include IOL axis measurements and refraction.

详细描述

Background During cataract surgery, an intraocular lens is implanted in the bag. A monofocal lens allows spherical correction only. 15% to 29% of patients with cataracts have more than 1.50 diopters of astigmatism according to current estimations.1 Astigmatic correction can be performed during cataract surgery: the main clear corneal incision can be done at the steep axis, limbal relaxing incisions (LRI) or by opposite clear corneal incision (OCCI) can be performed. These techniques are not fully predictable and stable over time.2 Optimal corneal astigmatic correction can be done by implantation of a toric intra-ocular lens(IOL), with predictable and stable results over time. The toric IOL must be positioned in the correct axis. Rotation of the lens will reduce the astigmatic correction. Approximately one degree of off-axis rotation results in a loss of up to 3.3% of the cylinder power. 3 It is crucial for the intraocular lens to keep its correct axis for optimal astigmatic correction.

A number of toric intraocular lens are approved for implantation such as - Acrysof toric (Alcon), Tecnis toric IOL (Abbott medical), STAAR toric IOL (STAAR surgical company). This study will examine T-flex (Rayner) IOL. The rotational and refractive stability of this IOL has been tested on a relatively small number of patients. 4, 5

Objective Examination of Rayner T-flex Toric IOLs (573T and 623T; Rayner Intraocular Lenses Ltd,East Sussex, United Kingdom) for spherical and astigmatic correction, and rotational stability.

Methods Prospective study on 50 eyes. Patients will be recruited during examination in pre-operative clinic. This examinations include visual acuity, slit-lamp biomicroscopy, applanation tonometry, fundus examination after instillation of tropicamide 0.5% and phenylephrine 10%, IOL calculation with IOLMaster(Zeiss), which also measures corneal astigmatism. After acquiring informed consent, further examinations will be done including corneal topography with Galilei Dual Scheimpflug Analyzer ( Zeimer Ophthalmology), and Tomey keratometer, auto-refractometry and subjective refraction.

Since corneal astigmatism is often binocular, patients with second eye corneal astigmatism, will be offered a toric IOL, even if unsuitable for inclusion in this study. All operations will be done by a senior surgeon, experienced in toric IOL implantations. Rayner T-flex Toric IOLs (573T / 623T; Rayner Intraocular Lenses Ltd,East Sussex, United Kingdom) will be implanted. IOL calculation will be done using Ranyer's online calculator (WWW.TORICIOL.RAYNER.COM).

研究设计

研究类型
Interventional
分配方式
Na
干预模型
Single Group
主要目的
Treatment
盲法
None

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Corneal astigmatism ≥ 2.00 measured by IOLMaster

排除标准

  • Pterygium (can be included 6 months after successful surgical excision)
  • Corneal pathologies including corneal scars causing corneal irregularity
  • Severe dry eye
  • Traumatic cataract
  • Pregnant women
  • Severe macular disease or macular atrophy

结局指标

主要结局

IOL off-axis rotation

时间窗: 3 months after surgery

IOL axis will be measured by slit lamp biomicroscopy and compared to the planned axis

次要结局

  • Subjective refraction(3 months after surgery)
  • Uncorrected distance visual acuity(3 months after surgery)
  • Corrected distance visual acuity(3 months after surgery)

研究者

申办方类型
Other Gov
责任方
Sponsor

研究点 (2)

Loading locations...

相似试验