VivaSight Left-sided Double Lumen Tube Study
- Conditions
- Intubation, Intratracheal
- Interventions
- Device: intubation with VivaSight double-lumen tubeDevice: intubation with standard double-lumen tubeProcedure: fiberoptic bronchoscopy
- Registration Number
- NCT03665896
- Lead Sponsor
- Javier H Campos
- Brief Summary
The VivaSight™-DLT is a new OLV (one lung ventilation) device that contains an embedded camera. Therefore, a potential advantage is the continuous assessment of DLT position through continuous monitoring of the camera. The embedded camera of VivaSight™-DLT is positioned at the tracheal opening of the double lumen tube. It allows for continuous monitoring of the carina and bronchial tube placement.
The purpose of this study is to determine if a double lumen tube (DLT) with an embedded video camera, the VivaSight DLT, can be used in similar fashion to the standard double lumen tube with fiberoptic bronchoscopy. More specifically, the investigators would like to know the difference in time to optimal position in the left bronchus between the VivaSight DLT and the standard DLT with fiberoptic bronchoscopy. In addition, the investigators would like to know if the embedded camera on the VivaSight DLT provides a view that will allow for the optimum position of the DLT in the left bronchus.
- Detailed Description
The investigators will perform a prospective, randomized study in thoracic surgical patients undergoing one-lung ventilation where the patient will receive either the VivaSight DLT or standard left-sided DLT. Subjects will be selected and evaluated who are at least 18 years old, but no older than 90 years old.
The investigators will compare the intubation time for the VivaSight™-DLT with the intubation time for standard DLT. The intubation time parameters for the VivaSight™-DLT are the passage of the tube through the vocal cords and the confirmation of proper tube positioning by the embedded camera. Fiberoptic bronchoscopy is performed to reassess the proper tube positioning, however, this will not be counted for the intubation time in this group. For the standard DLT, the intubation time parameter begins similarly, on the passage of the tube through the vocal cords, but ends with the confirmation of the proper placement by fiberoptic bronchoscopy. In both groups, C-MAC blade is used to visualize the passage of the tube through the vocal cords. These intubation times will be tracked real-time in the operating room and will be based upon both observation as well as the verbal confirmation of the attending anesthesiologist.
The intubation time must be within 5 minutes. The intubation time required more than 5 minutes is considered as unsuccessful intubation.
Recruitment & Eligibility
- Status
- COMPLETED
- Sex
- All
- Target Recruitment
- 40
- At least 18 years of age
- Adult patient undergoing scheduled thoracic surgery which requires double-lumen tube placement
- More than 90 years of age
- Patients with emergency surgery
- Prisoners
- Patient who cannot provide their own consent
- Patient refusal
- Non-English speaking patients
Study & Design
- Study Type
- INTERVENTIONAL
- Study Design
- PARALLEL
- Arm && Interventions
Group Intervention Description VivaSight DLT group intubation with VivaSight double-lumen tube Thoracic surgery patient is intubated with VivaSight double-lumen tube (intubation with VivaSight double-lumen tube). The intubation time, duration between the passage of the tube through the vocal cords and the confirmation of proper tube positioning by the embedded camera, is recorded. The tube position is reconfirmed by fiberoptic bronchoscopy. Standard DLT group intubation with standard double-lumen tube Thoracic surgery patient is intubated with standard double-lumen tube (intubation with standard double-lumen tube). The intubation time, duration between the passage of the tube through the vocal cords and the confirmation of proper tube positioning by fiberoptic bronchoscopy, is recorded. Standard DLT group fiberoptic bronchoscopy Thoracic surgery patient is intubated with standard double-lumen tube (intubation with standard double-lumen tube). The intubation time, duration between the passage of the tube through the vocal cords and the confirmation of proper tube positioning by fiberoptic bronchoscopy, is recorded. VivaSight DLT group fiberoptic bronchoscopy Thoracic surgery patient is intubated with VivaSight double-lumen tube (intubation with VivaSight double-lumen tube). The intubation time, duration between the passage of the tube through the vocal cords and the confirmation of proper tube positioning by the embedded camera, is recorded. The tube position is reconfirmed by fiberoptic bronchoscopy.
- Primary Outcome Measures
Name Time Method Intubation time Within 5 minutes We will compare the intubation time for the VivaSight double-lumen tube (DLT) with the intubation time for standard DLT.
- Secondary Outcome Measures
Name Time Method Picture reliability of the embedded camera of VivaSight double-lumen tube Within 10 hours Picture reliability of the embedded camera will be assessed based upon the proper identification of the following structures; a) Carina, b) Left bronchial cuff , c) A radiopaque line of left bronchial tube, d) Right main bronchus.