跳至主要内容
临床试验/NCT07321405
NCT07321405尚未招募不适用

Non Invasive Hemodynamic Assessment of Cardiac Output and Stroke Volume in Septic Shock Patients

Assiut University1 个研究点 分布在 1 个国家目标入组 100 人开始时间: 2026年4月1日最近更新:
适应症
干预措施

试验速览

阶段
不适用
状态
尚未招募
入组人数
100
试验地点
1
主要终点
to compare the accuracy and reliability of electrical cardiometry versus transthoracic echocardiography in measuring cardiac output in patients with septic shock.

研究概览

简要总结

The aim of this research is to compare the accuracy and reliability of electrical cardiometry versus transthoracic echocardiography in measuring cardiac output and stroke volume in patients with septic shock, to evaluate the potential of EC as a non-invasive alternative for hemodynamic monitoring.

详细描述

Sepsis is a life-threatening condition caused by a dysregulated immune response to infection, leading to organ dysfunction. It remains a leading global cause of morbidity and mortality, often progressing rapidly to septic shock and multi-organ failure if not promptly diagnosed and treated.

The complex pathophysiology involves systemic inflammation, endothelial damage, and impaired tissue perfusion, making early recognition and hemodynamic stabilization vital for survival. Accurate monitoring of cardiac function plays a key role in managing septic patients.

Cardiac output (CO) and stroke volume (SV) are key hemodynamic parameters guiding therapy in critically ill patients, particularly those with pneumonia and septic shock, who experience severe circulatory and respiratory dysfunction contributing to their high mortality.

Transthoracic echocardiography (TTE) is the gold standard for non-invasive bedside assessment of CO and SV, providing precise evaluation of cardiac structure and flow. However, TTE requires operator expertise, can be time-consuming, and may be limited by patient-specific factors.

Electrical cardiometry (EC) is an emerging non-invasive bio-impedance technique offering continuous monitoring with easier application and less operator dependency. Despite its advantages, EC's accuracy and reliability in critically ill septic patients require further validation.

研究设计

研究类型
Observational
观察模型
Cohort
时间视角
Prospective

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • patients aged more than 18 years must be diagnosed with septic shock following the surviving sepsis campaign

排除标准

  • patients aged less than 18 years pregnant women cases suffering cardiac diseases (heart failure, arrhythmia, moderate, and severe valvular disease) patients with poor quality echocardiographic images and measurements

研究组 & 干预措施

septic shock patients

echocardiography and electrical cardiometry will be applied to these patients

干预措施: echocardiogram (Device)

septic shock patients

echocardiography and electrical cardiometry will be applied to these patients

干预措施: Electrical cardiometry (Device)

结局指标

主要结局

to compare the accuracy and reliability of electrical cardiometry versus transthoracic echocardiography in measuring cardiac output in patients with septic shock.

时间窗: 2026-2028

to compare the accuracy and reliability of electrical cardiometry versus transthoracic echocardiography in measuring cardiac output in patients with septic shock.

cardiac output and stroke volume in septic shock patients

时间窗: baseline

comparison between accuracy and reliability in assessment of cardiac out put and stroke volume using echocardiogram vs electrical cardiometer

to compare the accuracy and reliability of electrical cardiometry versus transthoracic echocardiography in measuring stroke volume in patients with septic shock.

时间窗: 2026-2028

to compare the accuracy and reliability of electrical cardiometry versus transthoracic echocardiography in measuring stroke volume in patients with septic shock.

次要结局

未报告次要终点

研究者

申办方类型
Other
责任方
Principal Investigator
主要研究者

Osman Mohamed Osman Khalaf

resident physician

Assiut University

研究点 (1)

Loading locations...

相似试验

Assessment of Cardiac Output and Stroke Volume in... | 临床试验