跳至主要内容
临床试验/NCT06227338
NCT06227338招募中不适用

ICG-fluorescence Imaging for Intraoperative Breast Cancer Margins Evaluation: a Dose-timing Study

Jules Bordet Institute1 个研究点 分布在 1 个国家目标入组 250 人开始时间: 2024年2月12日最近更新:
适应症
干预措施
相关药物

试验速览

阶段
不适用
状态
招募中
入组人数
250
试验地点
1
主要终点
Accuracy of ICG-FI technique for the detection of positive (involved) surgical margins at the patient level

研究概览

简要总结

Designed in five-arm, single-center, prospective randomized, observational- interventional, open-label study which will evaluate patients with histological proven early-stage BC that will undergo planned BCS for their local treatment.

Two preoperatively times frames will be used for the administration of a total of 5 different indocyanine green (ICG) dose as a single dose-patient arm.

In the first time frame (intraoperative arms), the dose of, respectively 0.125 mg/kg and 0.25 mg/kg of ICG will be administered at induction anesthesia (at least 20 minutes before the BCS) in two subgroups.

In the second time frame, (preoperative arms), the dose of, respectively, 0.5 mg/kg, 1 mg/kg, and 2 mg/kg of ICG will be administered 24 h before surgery in 3 subgroups.

详细描述

The majority of breast cancer (BC) patients are diagnosed with an early-stage disease and are good candidates for breast-conserving surgery (BCS). Achieving adequate margins of excision is the most important component of BCS. Currently intra-operative margin assessment (IOMA) techniques used for margins evaluation in BC, either histological or imagistic is not accurate enough to predict the margins status of breast resected tumours and to guide surgery.

Fluorescence imaging (FI) using indocyanine green (ICG), a non-specific fluorophore, has also been reported to be a new, promising, non-invasive and relatively low cost technology to improving the accuracy of tumor detection during surgery in different clinical cancers, such as those of the liver, colon, ovaries, head and neck, lungs and breast. Furthermore ICG-FI can provide a real-time guidance during surgery and could establish corrects margins resection by improving the visual delineation between normal and tumoral tissues.

Only two clinical experience of ICG-FI for evaluating surgical margins in BC was reported. The group of Keating reported the first one, in a pilot study of 12 patients, after ICG intravenous (IV) injection (5mg/kg) they found that there was residual fluorescence in the tumoral bed in 6 out of 12 patients, but none of these patients had positive margins at definitive pathology. Recently, the investigators have reported the utility of ICG-FI after intraoperative ICG IV injection of 0.25 mg/kg for intraoperative breast surgical margin assessment during BCS. In a study of 35 BC patients, the investigators observed that the sensitivity (Se), specificity (Sp), and negative predictive value (NPV), of ICG-FI to predict margin involvement on the breast operative specimens were 100%, 60% and 100% respectively. Several important technical points exist in the experimental and clinical use of ICG-FI. There is a great variability of the published data regarding the baseline characteristics of the ICG use, like dosage and timing of administration (perioperative vs delayed). Furthermore, the fluorescence imaging system is usually different.

In this study, the investigators would like to emphasize and to get more precision about the optimal ICG doses and timing, which could increase the diagnostic accuracy of intraoperative ICG-FI for resection margins assessment during BCS, after intravenously ICG administration.

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Parallel
主要目的
Treatment
盲法
None

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
Female
接受健康志愿者

入选标准

  • age of ≥18 years;
  • histological diagnosis of ductal invasive breast cancer;
  • a primary early-stage invasive breast cancer (cT1 and/or cT2, assessed clinically and/or radiologically), without prior BC surgery of the actually affected breast;
  • ECOG Performance Status (PS) 0 or 1;
  • signed informed consent form (ICF) obtained prior to any study related procedure.

排除标准

  • advanced invasive breast cancer (cT3 and/or cT4);
  • in situ breast cancer disease;
  • lobular invasive breast cancer (at histology);
  • invasive breast cancer treated by neoadjuvant chemotherapy and/or endocrine therapy;
  • prior history of invasive or breast cancer of the actually affected breast in the past;
  • history of allergy or hypersensitivity to investigational product (active substance or ingredients);
  • history of allergy to iodine or to shellfish;
  • have apparent hyperthyroidism, autonomous thyroid adenoma, unifocal, multifocal, or disseminated autonomy of the thyroid gland;
  • documented coronary disease
  • advanced renal insufficiency (serum creatinine >1.5 mg/dL);
  • chronic liver disease with the Child-Pugh class B or C ;
  • concurrent medication which reduces or increases the elimination of indocyanine green dye (ie, anticonvulsants, haloperidol, and heparin) during the 2 weeks before the expected operation;
  • pregnant or lactating women;
  • inability to give informed consent.

研究组 & 干预措施

0.125 mg/kg

Experimental

Patients who will be injected with 0.125 mg/kg Indocyanine green before their tumorectomy

干预措施: Indocyanine green (Drug)

0.25 mg/kg

Experimental

Patients who will be injected with 0.25 mg/kg Indocyanine green before their tumorectomy

干预措施: Indocyanine green (Drug)

0.5 mg/kg

Experimental

Patients who will be injected with 0.5 mg/kg Indocyanine green before their tumorectomy

干预措施: Indocyanine green (Drug)

1 mg/kg

Experimental

Patients who will be injected with 1 mg/kg Indocyanine green before their tumorectomy

干预措施: Indocyanine green (Drug)

2 mg/kg

Experimental

Patients who will be injected with 2 mg/kg Indocyanine green before their tumorectomy

干预措施: Indocyanine green (Drug)

结局指标

主要结局

Accuracy of ICG-FI technique for the detection of positive (involved) surgical margins at the patient level

时间窗: 2 years

The sensitivity (Se), specificity (Sp), negative predictive value (NPV), false negative rate (FNR), FPR of the ICG-FI technique will be computed at the patient level

次要结局

  • Comparison of ICG-FI technique accuracy at different doses and timing(2 years)
  • Characterization of the breast tumor fluorescence (tumor-to- background fluorescence ratio)(2 years)
  • Evaluation of fluorescence intensity of axillary lymph nodes(2 years)

研究者

申办方类型
Other
责任方
Sponsor

研究点 (1)

Loading locations...

相似试验