MedPath

Prevention of Maternal Hypothermia After Scheduled Caesarean Section Using Active Intravenous Warming

Not Applicable
Conditions
Postoperative Hypothermia
Interventions
Device: enFlow® IV fluid warmer and from July 2019 Fluido®Compact IV fluid warmer
Registration Number
NCT03581721
Lead Sponsor
Assistance Publique - Hôpitaux de Paris
Brief Summary

Maternal hypothermia is very frequent after caesarean delivery under spinal anaesthesia and should be prevented, as it induces discomfort and increases the risk of postoperative complications. Several modalities of active warming have been explored, with contrasting results. Small IV Fluid warming systems offer effective and safe IV fluid warming without discomfort, and are very easy to use. The investigators hypothesize that such devices can efficiently prevent hypothermia after caesarean section even with high flow rates of infusion. The purpose of this study is to determine whether active fluid warming reduces the occurrence of maternal hypothermia after scheduled caesarean section, as compared with no active warming. The investigators plane to conduce a double-blinded randomized controlled trial. Seventy women undergoing scheduled caesarean section under spinal anaesthesia in 3 different maternity units will be included. The primary outcome is the occurrence of maternal hypothermia (\<36.0°C) on admission to the post anaesthesia care unit. The secondary outcomes are perioperative maternal hypothermia, maternal thermal discomfort, maternal recovery and neonatal well-being

Detailed Description

Hypothermia is a well-known complication of general and neuraxial anaesthesia. After a caesarean section under spinal anaesthesia, 30 to 40% of the mothers have a core temperature \<36°C. Perioperative hypothermia induces maternal thermal discomfort and shivering, but also increases the amount of blood loss and the risks of postoperative wound infections and cardiac complications. In addition, maternal hypothermia may also have an impact on neonatal outcomes. Prevention of maternal hypothermia in women scheduled for caesarean delivery is consequently necessary, and is an important part of enhanced recovery after surgery. Active warming is efficient in preventing postoperative hypothermia. Forced-air warming is the most commonly used modality of active warming. However forced-air warming should be applied for at least 60 minutes to be efficient. As surgical duration for a caesarean is lower than one hour, this technic does not appear really appropriate in this context. In addition, upper body forced-air warming is uncomfortable for women and can interfere with bonding. Consequently forced-air warming is not generally used during caesarean delivery. Warmed IV fluid is another option to prevent perioperative hypothermia, but with contrasting results, depending mainly on the device and on the amount of perioperative fluids infusion. Co-loading IV fluid is recommended to prevent maternal hypotension induced by spinal anaesthesia in the context of caesarean delivery. Small released fluid warmings routinely used in scheduled surgery, are able to warm IV fluid administered with high flows, such as in co-loading IV fluid. But the efficiency of these devices to prevent maternal hypothermia has never been explored in the context of caesarean section under spinal anaesthesia with co-loading.

The investigators hypothesized that warmed IV fluid administered in co-loading with enFlow® or Fluido®Compact decreases the incidence of postoperative maternal hypothermia after caesarean section under spinal anaesthesia.

The investigators will perform a double blinded randomized controlled trial comparing active IV warming with enFlow® or Fluido®Compact versus placebo.

Indeed at the beginning of the study, the performance of the enFlow device were tested. But in February 2019, a study published in Anaesthesia showed that uncoated aluminium plates in fluid warming systems, such as those used in the enFlow system, yielded potentially harmful concentrations of aluminium when using balanced electrolyte solutions (ref Perl Anaesthesia 2019). Consequently this device was quarantined unless there are no alternative fluid warmers available Of note no adverse event has been reported associated with the use of enFlow® device. Consequently, we choose to continue our study with the Fluido®Compact, which is a very similar small fluid warmer but with coated aluminium plate.

After obtaining written informed consent from the patients, 70 pregnant women ASA status 1 or 2 and scheduled for caesarean delivery will be enrolled and randomized into two groups: active IV fluid warming vs no active warming. Written informed consent will be obtained before randomisation using an Internet based randomisation system. Participants will be randomized just after their arrival in the operative room. The clinicians in charge of the patients, the researcher and the woman will be blinded. In the operative room, a venous cannula will be inserted into the forearm, and an infusion of Ringer's lactate solution fluids will be initiated. An enFlow® or Fluido®Compact device will be placed on the IV for all the patients, but turned on only in the group active warming. The device will be hidden in all the patients. Every patient will have a spinal anaesthesia in sitting position with hyperbaric bupivacaine 10mg, sufentanil 3µg and morphine 100µg. An IV co loading with Ringer-Lactate 1000 ml will be started at the beginning of the spinal administration. All the women will be monitored using heart rate, continuous SpO2, non-invasive arterial blood pressure every 1-minute until the baby is born, and then every 5 minutes. Maternal arterial hypotension will be corrected with ephedrine or phenylephrine as appropriate. All the women will receive carbetocin 100µg just after baby extraction. While in the operative room, all the data will be collected on a standardized data collection sheet. In case of maternal temperature \<35°C during surgery, an active warming blanket will be used. The enFlow® or Fluido®Compact device will be taken off at the end of the surgery just before leaving the operative room.

In addition, postoperative data will be collected during the admission to the post-anaesthesia care unit (PACU). In case of maternal temperature \<36°C in the PACU, a warming blanket will be used.

The sample size calculation revealed that 62 participants were required to ensure that a 30% decrease in the incidence of postoperative maternal hypothermia will be detected (power = 0.9 ; α= 0,05). The investigators decided to enroll 70 women because of the risks of secondary exclusions and of lost of follow up.

Recruitment & Eligibility

Status
UNKNOWN
Sex
Female
Target Recruitment
70
Inclusion Criteria

Pregnant women

  • without any major co-morbidity (ASA status 1 or 2),
  • with normal singleton pregnancy,
  • who will deliver by scheduled caesarean section under spinal anesthesia at gestational age ≥ 37 weeks of amenorrhea,
  • Aged ≥ 18 years
  • with health insurance
Exclusion Criteria
  • Patient refusal to participate in the study
  • Maternal temperature ≥38.0 ° C or <36.0 ° C at the time of randomization,
  • Spinal anaesthesia refused or contraindicated,
  • unplanned caesarean section
  • caesarean delivery scheduled since less than 48 hours
  • caesarean section performed under epidural or general anesthesia
  • participation of the mother in another interventional research or intervention, or during the exclusion period following a previous search
  • unability to give written consent
  • body mass index> 40kg / m2
  • gravidic hypertensive disease
  • uncontrolled diabetes
  • cardiovascular disease under treatment
  • coagulation disorder

Study & Design

Study Type
INTERVENTIONAL
Study Design
PARALLEL
Arm && Interventions
GroupInterventionDescription
The warming groupenFlow® IV fluid warmer and from July 2019 Fluido®Compact IV fluid warmer"IV fluid warming with the enFlow® or Fluido®Compact IV fluid warmer" : Women will receive IV fluid coload warmed to 40°C through the enFlow® or Fluido®Compact device. The box will be also hidden. The fluid warmer will be turned off at the end of surgery, just before transfer to the PACU.
Primary Outcome Measures
NameTimeMethod
Incidence of Maternal postoperative hypothermiauntil Hour 12

Obtained by placing a skin sensor on the right temporal region and measured using the 3M™ SpotOn™ Monitoring System on arrival at the PACU Hypothermia is defined as a Temperature \<36°C

Secondary Outcome Measures
NameTimeMethod
Hemoglobin concentrationone day after surgery

blood test

Postpartum anemiaOne day after surgery

Maternal hemoglobin concentration

Maternal ShiveringUntil Hour 12

Measured on a 4 points scale (0 = no chills, 1 = intermittent, low intensity, 2 = moderate, 3 = continuous) Just before the spinal anesthesia and every 10 minutes in the operative room

Maternal shiveringUntil Hour 12

Score of 4 points (0 = no chills, 1 = intermittent, low intensity, 2 = moderate, 3 = continuous and intense) On arrival at SSPI, one hour and 2 hours after, and just before leaving the PACU

Maternal Thermal discomfortUntil Hour 12

Numerical scale between 0 and 100 (0: absence of thermal discomfort, 100: extreme thermal discomfort) On arrival at SSP, one hour and 2 hours after, and just before leaving the PACU

Need of active maternal warmingUntil Hour 12

use of a air forced warming blanked, peroperatively and Until H2 after surgery

Neonatal core hypothermiaWithin 30th minutes of life

Measure of Temperature °C with cutaneous thermometer

Apgar scoreminute 10 after birth

Clinically evaluated :assessment of the newborn infant well-being

Arterial umbilical pH measurement (physiological parameter)Within 30th minutes of life

Blood test

Arterial umbilical base deficit measurementWithin 30th minutes of life

Blood test

Variation in perioperative hemoglobinemiaWithin 24hours before cesarean and one day after surgery

Blood test

Maternal postoperative recoverybetween day 3 and day 5 after surgery

6-minute walk test (6 MWT)

Estimation of Quality of lifeat the time of the postoperative appointment, around 40 days after surgery

The WHOQOL-BREF instrument comprises 26 items, which measure the following broad domains: physical health, psychological health, social relationships, and environment.

Trial Locations

Locations (1)

Cochin Hospital, Port-Royal Maternity

🇫🇷

Paris, France

© Copyright 2025. All Rights Reserved by MedPath