跳至主要内容
临床试验/NCT07665008
NCT07665008已完成不适用

MULTIDIMENSIONAL ASSESSMENT OF MUSCLE FATIGUE USING ACCELEROMETER, ELECTROMYOGRAPHY AND MUSCLE THICKNESS DATA

Giresun University1 个研究点 分布在 1 个国家目标入组 30 人开始时间: 2024年11月1日最近更新:

试验速览

阶段
不适用
状态
已完成
入组人数
30
试验地点
1

研究概览

简要总结

Muscle fatigue is a multifactorial physiological phenomenon characterized by a reduction in the ability of a muscle to generate force during sustained or repetitive contractions. This cross-sectional observational study aimed to investigate the relationships among muscle thickness, surface electromyography (sEMG) median frequency, accelerometer-derived mechanical vibration parameters, and isometric force characteristics in healthy male soccer players. Thirty participants aged 18-30 years underwent ultrasonographic muscle thickness assessment, synchronized sEMG and accelerometer recordings, and isometric strength testing at different knee flexion angles (90°, 60°, and 30°). The study evaluated the interaction between morphological, electrical, and mechanical indicators of muscle fatigue to support the development of multidimensional fatigue monitoring approaches.

详细描述

Muscle fatigue is commonly assessed using surface electromyography (sEMG), particularly through frequency-domain parameters such as median frequency. However, fatigue-related changes are not limited to electrical activity and may also involve alterations in muscle mechanical behavior and morphological characteristics. Accelerometer-derived signals provide information regarding muscle vibrations and mechanical oscillations, while ultrasonographic measurements of muscle thickness provide information about muscle morphology and force-generating capacity.

The purpose of this study was to examine the relationships among muscle thickness, sEMG median frequency, accelerometer-derived mechanical vibration parameters, and isometric force variables during maximal voluntary isometric contractions performed at different knee flexion angles. Healthy male soccer players participated in a laboratory-based assessment protocol including ultrasonography, synchronized sEMG recordings, triaxial accelerometry, and isokinetic dynamometry.

Muscle thickness of the vastus lateralis obliquus (VLO), vastus medialis obliquus (VMO), and rectus femoris obliquus (RFO) muscles was measured using ultrasonography. Participants subsequently performed maximal voluntary isometric contractions at 90°, 60°, and 30° knee flexion angles. Surface electromyography, accelerometer signals, and force-related variables were recorded simultaneously. Median frequency values, acceleration-based root mean square (RMS) parameters, peak torque, mean torque, and time-to-peak torque variables were analyzed.

The study aimed to provide a multidimensional framework for muscle fatigue assessment by integrating morphological, electrical, and mechanical indicators and to explore their associations in healthy athletic populations.

研究设计

研究类型
Observational
观察模型
Other
时间视角
Cross Sectional

入排标准

年龄范围
18 Years 至 30 Years(Adult)
性别
Male
接受健康志愿者

入选标准

  • Healthy male soccer players aged 18-30 years
  • No lower extremity injury within the previous six months
  • No condition limiting lower extremity exercise performance
  • No caffeine or stimulant consumption on the testing day
  • Non-smoker
  • Provided written informed consent

排除标准

  • Female athletes
  • Serious injury to the dominant leg within the previous year
  • Intense exercise within the previous 24 hours
  • Use of pain relievers or muscle relaxants on the testing day
  • Inability to complete testing procedures

研究者

申办方类型
Other
责任方
Principal Investigator
主要研究者

Tugce Namazci

research assistant

Giresun University

研究点 (1)

Loading locations...

相似试验