Surgical Vs Transcatheter Aortic Valve Replacement in Young Patients
- Conditions
- Symptomatic Severe Aortic Stenosis
- Registration Number
- NCT06861361
- Lead Sponsor
- Ceric Sàrl
- Brief Summary
The study objective is to demonstrate that the clinical outcomes of the Myval balloon-expandable THV series are non-inferior to those of SAVR in patients with symptomatic severe aortic stenosis aged 65 to 75 years.
- Detailed Description
Prospective, randomized, multinational, multicenter, open label, trial of 1180 patients treated with surgical bioprosthetic aortic valve replacement (SAVR) or transcatheter aortic valve replacement (TAVR).
Recruitment & Eligibility
- Status
- NOT_YET_RECRUITING
- Sex
- All
- Target Recruitment
- 1180
Participant will be included if all the following criteria are met:
- Patients aged ≥65 and ≤75
- Symptomatic severe aortic stenosis (mean gradient≥40mmHg, and or peak velocity>4m/sec).
- Patients with symptomatic heart disease due to severe native calcific aortic stenosis, as judged by a multidisciplinary heart team (including a cardiac surgeon), for whom SAVR or transfemoral TAVR is deemed feasible and approved by the local heart team.Signed informed consent for participation in the clinical investigation
Participant will not be included if any one of the following conditions exists:
- Unable to understand and follow clinical investigation-related instructions or unable to comply with the clinical investigation protocol
- Life expectancy less than 1 year
- Known hypersensitivity or allergy to aspirin, clopidogrel or any Device frame components.
- Under judicial protection, tutorship, or curatorship
- Participation in another trial before the primary endpoint
Study & Design
- Study Type
- INTERVENTIONAL
- Study Design
- PARALLEL
- Primary Outcome Measures
Name Time Method Primary safety endpoint at 1 month (non-inferiority): Composite measure of all-cause death, any stroke, bleeding, AKI stage 2-4, rehospitalization for a procedure-related event or or reintervention for aortic valve dysfunction. 1 month post procedure Composite measure of all-cause death, any stroke, VARC-3 type 1 (only overt bleeding that requires a transfusion of 1 unit of whole blood/red blood cells (BARC 3a), type 2 and 3 bleeding, AKI stage 2-4, rehospitalization for a procedure-related event or reintervention for aortic valve dysfunction.
Primary efficacy endpoint at 1 year (non-inferiority): Composite measure of all-cause death, any stroke, or rehospitalization for valve related event 1 year post procedure Composite measure of all-cause death, any stroke, or rehospitalization for valve related event at 1 year (VARC-3 definition)
CT Scan Sub Study endpoints: primary endpoint : prevalence of feasible redoTAVR or ViV TAVR without requiring leaflet modifications techniques (green cases). 1 month post procedure Proportion of participants classified as "green cases" (redo-TAVR or ViV-TAVR feasible without leaflet modification) based on predefined CT scan criteria, including annular dimensions, coronary access, and valve frame interactions.
- Secondary Outcome Measures
Name Time Method Secondary Endpoint: Individual components of the primary endpoints: all cause mortality over time 1, 2, 3 and 5 years Number of participants who experience all-cause mortality at each follow-up time point.
Secondary Endpoint: Individual components of the primary endpoints: Stroke Over Time 1, 2, 3 and 5 years Number of participants with any stroke (ischemic or hemorrhagic) as defined by clinical assessment and imaging confirmation.
Secondary Endpoint: Individual components of the primary endpoints: Rehospitalization for Procedure-Related Event Over Time 1, 2, 3 and 5 years Number of participants requiring rehospitalization due to procedure-related complications.
Secondary Endpoint: Feasibility of re-TAVR based on CT scan evaluation (CT scan, for selected sites only) 1 month post procedure Number of participants in whom redo-TAVR is deemed feasible based on CT scan evaluation.
Feasibility will be assessed using predefined anatomical criteria, including:
Annular dimensions Coronary access Valve frame interactions Need for leaflet modification techniques Feasibility will be categorized as: "Feasible without modification," "Feasible with modification," or "Not feasible.Secondary Endpoint: Individual components of the primary endpoints: Bleeding Events (VARC-3 Type 1, 2, and 3) Over Time 1, 2, 3 and 5 years Number of participants experiencing bleeding events classified as VARC-3 type 1 (BARC 3a), type 2 and 3.
* Scoring System: Valve Academic Research Consortium (VARC) scale:
* 1
* Overt bleeding not requiringing surgical or percutaneous intervention, but requiring medical intervention, leading to hospitalization, an increased level of care, or medical evaluation
* Overt bleeding requiring a transfusion of 1 unit of whole blood/RBC
* 3
* Overt bleeding in a critical organ, such as intracranial, intraspinal, intraocular, pericardial or intramuscular with compartment syndrome
* Overt bleeding causing hypovolemic shock or severe hypotension
* Overt bleeding requiring reoperation, surgical exploration, or re-intervention for the purpose of controlling bleeding
* Post-thoracotomy chest tube output ≥2 L within 24-h
* Overt bleeding requiring a transfusion of ≥5 units of whole blood/RBC
* Overt bleeding associated with a haemoglobin drop ≥5 g/dL
* Higher scores indicate worst outcomesSecondary Endpoint: Individual components of the primary endpoints: Acute Kidney Injury (AKI) Stage 2-4 Over Time 1, 2, 3 and 5 years Number of participants with acute kidney injury (AKI) stage 2-4 based on VARC-3
* Scale Information: AKI from Valve Academic Research Consortium 3 (VARC-3):
* Scoring System:
* Stage 1: AKI that fulfils at least one of the following criteria:
* Increase in serum creatinine ≥150-200% (≥1.5-2.0x increase) within 7 days compared with baseline
* Increase of ≥ 0.3mg/dL (≥26.4 μmol/L) within 48 h of the index procedure
o Stage 2: AKI that fulfils the following criterion:
* Increase in serum creatinine \>200-300% (\>2.0-3.0x increase) within 7 days compared with baseline
o Stage 3: AKI that fulfils at least one of the following criteria:
* Increase in serum creatinine \>300% (\>3.0x increase) within 7 days compared with baseline
* Serum creatinine ≥4.0 mg/dL (≥354 μmol/L) with an acute increase of ≥0.5 mg/dL (≥44 μmol/L)
* Stage 4: AKI requiring new temporary or permanent renal replacement therapy
* Interpretation: Higher stages indicate more severe kidney injurySecondary Endpoint: Individual components of the primary endpoints: Reintervention for Aortic Valve Dysfunction Over Time 1, 2, 3 and 5 years Number of participants requiring reintervention (redo-TAVR, SAVR, or valve explantation) due to aortic valve dysfunction.
Secondary Endpoint: Number of Participants Requiring New Permanent Pacemaker Implantation (PPI) Due to Conduction System Disturbances 1 month post procedure Number of participants who require a new permanent pacemaker implantation (PPI) within 1 month post-procedure due to conduction system disturbances (e.g., high-degree atrioventricular block, left bundle branch block).
Indications for PPI will be based on standard clinical guidelines.Secondary Endpoint: Rate of prosthetic valve regurgitation (moderate or severe) 1 year post procedure Secondary Endpoint: Number of Participants with Major Vascular Complications (VARC-3 Criteria) 1 month post procedure Number of participants experiencing major vascular complications within 1 month post-procedure, as defined by VARC-3 criteria.
o Scoring System: Valve Academic Research Consortium-3 (VARC-3) criteria o Definition: MAJOR vacular complication: One of the following:
• Aortic dissection or aortic rupture • Vascular injury or compartment syndrome resulting in death,VARC type ≥2 bleeding, limb or visceral ischaemia, or irreversible neurologic impairment • Distal embolization (non-cerebral) from a vascular source resulting in death, amputation, limb or visceral ischaemia, or irreversible end-organ damage • Unplanned endovascular or surgical intervention resulting in death, VARC type ≥2 bleeding, limb or visceral ischaemia, or irreversible neurologic impairment • Closure device failure resulting in death, VARC type ≥2 bleeding, limb or visceral ischaemia, or irreversible neurologic impairmentSecondary Endpoint: Performance of the aortic valve : paravalvular leakage (PVL) grade evaluated by transthoracic echocardiogram (TTE) 1 year and 3 years post procedure Number of participants stratified by paravalvular leakage (PVL) grade (None, Mild, Moderate, Severe), as assessed by TTE.
PVL severity will be determined based on echocardiographic parameters defined by the VARC-3 criteria.Secondary Endpoint: Performance of the aortic valve : effective orifice are (EOA) evaluated by transthoracic echocardiogram (TTE) 1 year and 3 years post procedure Effective orifice area (EOA) (cm²) measured using the continuity equation on TTE.
Values will be reported as mean ± standard deviation (SD).Secondary Endpoint: Number of Participants with Structural Valve Deterioration (VARC-3) and/or Requiring Redo-TAVR or Valve Explantation 5 years post procedure Number of participants experiencing significant structural valve deterioration (SVD) as defined by VARC-3 criteria.
SVD will be assessed by transthoracic echocardiography (TTE) Number of participants requiring redo-TAVR or surgical valve explantation within 5 years post-procedure.CT Scan Sub Study endpoints: Secondary outcomes : feasibility of redoTAVR or ViV TAVR with or without requiring leaflet modification techniques 1 month post procedure Proportion of participants in whom redo-TAVR or ViV-TAVR is feasible, with or without requiring leaflet modification techniques, based on CT scan evaluation. Classification will be based on predefined anatomic and hemodynamic feasibility criteria.
CT Scan Sub Study endpoints: Secondary outcomes: Impact of HALT on Effective Orifice Area (EOA) - Valve Hemodynamics 1 month post procedure * Outcome Measure: Mean change in effective orifice area (cm²) in participants with and without HALT, measured by transthoracic echocardiography (TTE).
* Time Frame: 1 month post-procedure
* Unit of Measure: cm²
* Interpretation: A lower EOA suggests impaired valve opening and increased risk of stenosis.CT Scan Sub Study endpoints: Secondary outcomes: Mean Transvalvular Gradient - THV Hemodynamics 1 month post procedure * Outcome Measure: Mean transvalvular gradient (mmHg) measured by TTE post-implantation.
* Time Frame: 1 month post-procedure
* Unit of Measure: mmHg
* Interpretation: Higher gradients indicate increased obstruction.CT Scan Sub Study endpoints: Secondary outcomes: Peak Transvalvular Gradient - THV Hemodynamics 1 month post procedure * Outcome Measure: Peak transvalvular gradient (mmHg) measured by TTE post-implantation.
* Time Frame: 1 month post-procedure
* Unit of Measure: mmHg
* Interpretation: Higher peaks indicate more severe stenosis.CT Scan Sub Study endpoints: Secondary outcomes: Effective Orifice Area (EOA) - THV Hemodynamics 1 month post procedure * Outcome Measure: Effective orifice area (cm²) measured by TTE post-implantation.
* Time Frame: 1 month post-procedure
* Unit of Measure: cm²Secondary Endpoint: Performance of the aortic valve : Gradients (mean/max) assessed by TTE 1 year and 3 years post procedure Mean and peak aortic valve gradients (mmHg) will be measured by transthoracic echocardiography (TTE) at each follow-up time point.
Values will be reported as mean ± standard deviation (SD).CT Scan Sub Study endpoints: Secondary outcomes: prevalence of HALT in both TAVR and SAVR groups 1 month post procedure Number of participants with HALT detected on CT scan in both TAVR and SAVR groups. HALT will be defined as the presence of hypo-attenuated leaflet thickening observed on post-procedure CT imaging.
CT Scan Sub Study endpoints: Secondary outcomes: Impact of HALT on Mean Transvalvular Gradient - Valve Hemodynamics 1 month post procedure * Outcome Measure: Mean change in mean transvalvular gradient (mmHg) in participants with and without HALT, measured by transthoracic echocardiography (TTE).
* Time Frame: 1 month post-procedure
* Unit of Measure: mmHg
* Interpretation: A higher mean transvalvular gradient suggests increased valve obstruction.CT Scan Sub Study endpoints: Secondary outcomes: Impact of HALT on Peak Transvalvular Gradient - Valve Hemodynamics 1 month post procedure * Outcome Measure: Mean change in peak transvalvular gradient (mmHg) in participants with and without HALT, measured by transthoracic echocardiography (TTE).
* Time Frame: 1 month post-procedure
* Unit of Measure: mmHg
* Interpretation: A higher peak transvalvular gradient indicates greater hemodynamic burden on the valve.CT Scan Sub Study endpoints: Secondary outcomes: Commissural Alignment of THV 1 month post procedure Mean commissural misalignment angle (degrees) measured by CT scan to evaluate THV positioning relative to native aortic valve commissures.
Related Research Topics
Explore scientific publications, clinical data analysis, treatment approaches, and expert-compiled information related to the mechanisms and outcomes of this trial. Click any topic for comprehensive research insights.