A New Intelligent Stocking for Quantification of Edema in the Lower Limbs

Recruiting
Conditions
Edema Leg
Interventions
Device: Single volume measurement with ESD
Device: Single volume measurement with WDV
Device: Single circumference measurement with tape measure
Device: Continuous volume measurement with ESD
Registration Number
NCT05310435
Lead Sponsor
University of Aarhus
Brief Summary

The purpose of the study is to evaluate a prototype of an intelligent stocking (Edema Stocking Device \[ESD\]), consisting of two stretch sensitive sensors, as a new method for continuously lower leg volume monitoring. The study is a scientific evaluation of the ESD compared with water displacement volumetry and tape measure.

Detailed Description

Background:

Balance of body fluids is strictly regulated within a narrow range and is controlled by water movement between the interstitial compartment and the capillaries. An unnatural balance between the two compartments can be seen in several diseases, leading to a net filtration out of the vascular space, resulting in the formation of edema. Monitoring of edema formation represents a unique way of evaluating the degree of the underlying disease and effect of treatment. Numerous different methods can be used to quantify leg volume. However, no current method provides continuous quantitative assessment. The feasibility of continuous lower leg measuring using an intelligent stocking was hypothesized.

The aim of the study was to evaluate the Edema Stocking device (ESD) as a tool for continuous quantification of edema compared with water displacement volumetry (WDV) and tape measure.

Materials and methods:

Study design: Non-randomized equivalence study. Experimental comparison study of new method compared to golden standard.

Recruitment & Eligibility

Status
RECRUITING
Sex
Female
Target Recruitment
20
Inclusion Criteria
  • Edema of the lower legs.
  • Between 20-18 years.
  • Identified at Department of Gynaecology and Obstetrics, Aarhus University Hospital, Denmark.
Exclusion Criteria
  • Length of lower leg of more than 34,0 cm (measured from floor to knee).

Study & Design

Study Type
OBSERVATIONAL
Study Design
Not specified
Arm && Interventions
GroupInterventionDescription
Pregnant women with lower leg edemaSingle volume measurement with WDVPregnant women with clinical lower leg edema measured two times with Edema Stocking device, two times with water displacement volumetry and two with tape measure each day for three days.
Pregnant women with lower leg edemaSingle circumference measurement with tape measurePregnant women with clinical lower leg edema measured two times with Edema Stocking device, two times with water displacement volumetry and two with tape measure each day for three days.
Pregnant women with lower leg edemaContinuous volume measurement with ESDPregnant women with clinical lower leg edema measured two times with Edema Stocking device, two times with water displacement volumetry and two with tape measure each day for three days.
Pregnant women with lower leg edemaSingle volume measurement with ESDPregnant women with clinical lower leg edema measured two times with Edema Stocking device, two times with water displacement volumetry and two with tape measure each day for three days.
Primary Outcome Measures
NameTimeMethod
Leg circumference measured with ESD (mm)60 minutes

Obtained with the Edema Stocking Device

Leg volume measured with ESD (ml)1 minute

Obtained with the Edema Stocking device

Leg volume measured with WDV (ml)1 minute

Obtained with water displacement volumetry

Leg circumference measured with tape measure (mm)1 minute

Obtained with tape measure

Secondary Outcome Measures
NameTimeMethod

Trial Locations

Locations (1)

Department og Gynaecology and Obstetrics, Aarhus University Hospital

🇩🇰

Aarhus, Denmark

© Copyright 2025. All Rights Reserved by MedPath