MedPath

The ENDEAVOR Pharmacokinetic (PK) Registry: The Medtronic Endeavor Drug Eluting Coronary Stent System

Not Applicable
Completed
Conditions
Coronary Artery Disease
Interventions
Device: Coronary Artery Stenting
Device: Endeavor
Registration Number
NCT00314275
Lead Sponsor
Medtronic Vascular
Brief Summary

The purpose of this study is to evaluate the pharmacokinetics (PK) and safety associated with ABT-578 administered using the Medtronic Endeavor Drug Eluting Coronary Stent system in the treatment of single de novo lesions in native coronary arteries between 2.5 - 3.5 mm in diameter.

Detailed Description

Not available

Recruitment & Eligibility

Status
COMPLETED
Sex
All
Target Recruitment
43
Inclusion Criteria
  • The patient is at least 18 years of age.
  • The patient has clinical evidence of ischemic heart disease, stable or unstable angina, silent ischemia, or a positive functional study.
  • The patient is an acceptable candidate for percutaneous transluminal coronary angioplasty (PTCA), stenting, and emergent coronary artery bypass graft (CABG) surgery.
  • Female patients of childbearing potential must have a negative pregnancy test within 7 days before the procedure.
  • The patient or patient's legal representative has been informed of the nature of the study and agrees to its provisions and has provided written informed consent as approved by the Institutional Review Board of the respective clinical site.
Exclusion Criteria
  • A known hypersensitivity or contraindication to aspirin, heparin or bivalirudin, ticlopidine or clopidogrel, cobalt, nickel, chromium, molybdenum, polymer coatings, or a sensitivity to contrast media, which cannot be adequately pre-medicated.
  • History of an allergic reaction or significant sensitivity to drugs similar to ABT-578, rapamycin, tacrolimus, everolimus, or any other analog or derivative.
  • A platelet count < 100,000 cells/mm³ or > 700,000 cells/mm³, or a white blood cell (WBC) count < 3,000 cells/mm³.
  • A creatinine level > 2.0 mg/dL within seven days prior to index procedure. Evidence of an acute myocardial infarction within 72 hours of the intended treatment (defined as: Q wave or non-Q wave myocardial infarction having creatine kinase [CK] enzymes greater than or equal to 2 X the upper laboratory normal with the presence of a creatine kinase myocardial-band isoenzyme [CK-MB] elevated above the institution's upper limit of normal).
  • Previous percutaneous coronary intervention (PCI) of the target vessel within 9 months pre-procedure.
  • Planned PCI of any vessel within 30 days post-procedure.
  • During the index procedure, the target lesion requires treatment with a device other than PTCA prior to stent placement (such as, but not limited to: cutting balloon, directional coronary atherectomy, excimer laser, rotational atherectomy, thrombectomy, etc.).
  • History of a stroke or transient ischemic attack within the prior 6 months. Active peptic ulcer or upper gastrointestinal (GI) bleeding within the prior 6 months.
  • History of bleeding diathesis or coagulopathy or will refuse blood transfusions.
  • Concurrent medical condition with a life expectancy of less than 12 months. Any previous or planned treatment of the target vessel with anti-restenotic therapies including, but not limited to, brachytherapy.
  • Currently participating in an investigational drug or another device study that has not completed the primary endpoint or that clinically interferes with the current study endpoints; or requires coronary angiography, intravascular ultrasound (IVUS) or other coronary artery imaging procedures.

Study & Design

Study Type
INTERVENTIONAL
Study Design
SINGLE_GROUP
Arm && Interventions
GroupInterventionDescription
ENDEAVORCoronary Artery StentingDrug Eluting Stent
ENDEAVOREndeavorDrug Eluting Stent
Primary Outcome Measures
NameTimeMethod
Pharmacokinetic parameters (Cmax, Tmax, AUC, T1/2, CL, etc.)9 months
Secondary Outcome Measures
NameTimeMethod
Success (device, lesion, and procedure)9 months
Major adverse cardiac event (MACE) rate30 days, 6, 9 and 12 months
Target site revascularization (TSR), target vessel revascularization (TVR), and target vessel failure (TVF) rate9 months
For patients receiving overlapping stents at the target lesion: angiographic parameters (in-stent and in-segment), including: late lumen loss8 months
Late loss index9 months
Angiographic binary restenosis (ABR) rate9 months
Minimum luminal diameter (MLD)9 months
Percent diameter stenosis (%DS)9 months
Neointimal hyperplastic volume as measured by intravascular ultrasound (IVUS)8 months

Trial Locations

Locations (1)

Santa Rosa Memorial Hospital

🇺🇸

Santa Rosa, California, United States