跳至主要内容
临床试验/NCT02212301
NCT02212301已完成不适用

Comparison of Two Marketed Lenses in a Controlled Environment

Johnson & Johnson Vision Care, Inc.1 个研究点 分布在 1 个国家目标入组 45 人开始时间: 2014年7月1日最近更新:
适应症
干预措施

试验速览

阶段
不适用
状态
已完成
入组人数
45
试验地点
1
主要终点
Time Controlled Visual Acuity

研究概览

简要总结

This study is comparing two silicone hydrogel contact lenses in a controlled environment for identification of characteristics associated to vision.

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Crossover
主要目的
Treatment
盲法
Single (Participant)

入排标准

年龄范围
18 Years 至 50 Years(Adult)
性别
All
接受健康志愿者
是

入选标准

  • •The subject must be 18 years of age and less than 51 years of age;
  • •The subject must have read and understood the Participant Information Sheet;
  • •The subject must have read, signed and dated the Informed Consent;
  • •The subject must be a current planned replacement soft contact lens wearer;
  • •The subject must be a regular user of devices (computer, tablet and/or smart phone) for a minimum average of 5 ± 1 hours per day in a typical week
  • •The subject must have a refractive error within the range of correction of both study contact lenses;
  • •The subject must have a best-corrected visual acuity of 6/9 (20/30, 0.18 LogMAR) or better in each eye;
  • •The subject must demonstrate an acceptable fit with both study contact lenses;
  • •The subject must agree to wear their contact lenses as directed for the duration of the study (every day or for at least a minimum of five days per week for a minimum of six hours per day and be willing and able to adhere to the instructions set in the clinical protocol and maintain the appointment schedule;
  • •The subject must have normal eyes with the exception of the need for visual correction.

排除标准

  • •Any known sensitivity or intolerance to any of the contact lenses or adjunct products to be used.
  • •Monocular vision (only one eye with functional vision or only one eye fitted with contact lenses).
  • •Use of systemic or ocular concomitant medications which, as determined by the investigator, might contraindicate or interfere with contact lens wear.
  • •Ocular anterior segment infection, inflammation, abnormality, or active disease, which would contraindicate contact lens wear.
  • •Any moderate or severe ocular condition observed during slit lamp examination at the enrollment visit.
  • •A history of herpetic keratitis, ocular surgery or irregular cornea(s).
  • •Known pregnancy or lactation during the study period.
  • •Enrollment of investigator's office staff, relatives, or members of their respective households.
  • •Participation in any clinical trial within 30 days of the enrollment visit.

研究组 & 干预措施

senofilcon A / lotrafilcon B

Active Comparator

Subjects were randomized to one of two lens wear sequences. Subjects randomized to this sequence first wore the senofilcon A contact lens and then wore the lotrafilcon B contact lens.

干预措施: senofilcon A (Device)

senofilcon A / lotrafilcon B

Active Comparator

Subjects were randomized to one of two lens wear sequences. Subjects randomized to this sequence first wore the senofilcon A contact lens and then wore the lotrafilcon B contact lens.

干预措施: lotrafilcon B (Device)

lotrafilon B/ senofilcon A

Active Comparator

Subjects were randomized to one of two lens wear sequences. Subjects randomized to this sequence first wore the lotrafilcon B contact lens and then wore the senofilcon A contact lens

干预措施: senofilcon A (Device)

lotrafilon B/ senofilcon A

Active Comparator

Subjects were randomized to one of two lens wear sequences. Subjects randomized to this sequence first wore the lotrafilcon B contact lens and then wore the senofilcon A contact lens

干预措施: lotrafilcon B (Device)

结局指标

主要结局

Time Controlled Visual Acuity

时间窗: 8 hours post insertion

The Time Controlled Visual Acuity test is a proprietary test part of MG Vision Advanced Visual Performance Assessment. The test for distance vision is carried out at 4m under high contrast and dim luminance. The test is presented on a fast response 17" LCD screen (1280 by 1064). The test for intermediate vision is carried out at 64cm under high contrast dim luminance. The test was presented on a fast response 13.3" LCD screen (3200 by 1800). Visual acuity will be measured in a controlled environment using logMAR units.

Tear Film Kinetics

时间窗: 8 hour post insertion

The non-invasive tear film break-up-time (NIBUT) is the time elapsed (in seconds) between eye opening after a blink, and the appearance of the first dark spot within the tear film when observed with the wide diffuse light source of the Tearscope. This measurement is indicative of the tear film stability and the on eye wettability of contact lenses.

次要结局

未报告次要终点

研究者

申办方类型
Industry
责任方
Sponsor

研究点 (1)

Loading locations...

相似试验