Intermittent Pneumatic Compression of the Foot vs Geko Plus R-2 Neuromuscular Electrostimulation Device in Venous Leg Ulcer Patients

Not Applicable
Withdrawn
Conditions
Venous Leg Ulcer
Interventions
Device: geko plus R-2
Registration Number
NCT02912858
Lead Sponsor
Firstkind Ltd
Brief Summary

Chronic venous leg ulcers (VLU) are painful, debilitating wounds that place a significant burden on the patient, their family, and healthcare resources. Treating VLU can present a significant challenge to clinicians, who currently have a limited range of treatments at their disposal. The mainstay of treatment is compression bandaging, ambulation and elevation at rest. In addition to the aforementioned, intermittent pneumatic compression has also been utilised1. When applied to the leg or foot intermittent pneumatic compression (IPC) devices intermittently inflate and deflate to increase venous return. These devices can be uncomfortable to wear, and compliance can be inhibited because of size, weight and external power source that limit the patient's mobility. In patients who cannot walk, or in those who are unable to tolerate compression bandaging, ulcers may deteriorate and never heal. Accordingly, there is a need for novel, alternative devices or strategies that can be used to complement or replace compression bandage therapy.

Detailed Description

This is a single-centre randomised intra-patient comparison of gekoTM plus R-2 R-2 and IPC.

Blood flow will be measured after each device has been activated for 10 minutes with a 10 minute rest between devices to allow blood flow to return to baseline. The order the devices will be fitted is determined randomly. Activation of the device for 10 minutes before measurement is deemed appropriate as previous studies have demonstrated significant increases in blood flow following as little as five minutes use of the devices.

In this short study the standard of care (typically compression bandaging), will be suspended temporarily to allow the fitting of the gekoTM plus R-2 and IPC devices in order to measure blood flow. This is not seen as a risk to the patient as the device is only in operation for 30 minutes plus 10 minutes rest within the care pathway.

Recruitment & Eligibility

Status
WITHDRAWN
Sex
All
Target Recruitment
Not specified
Inclusion Criteria
  1. Age ≥ 18 years
  2. Intact healthy skin at the site of device application
  3. Able to understand the Patient Information Sheet
  4. Willing and able to give informed consent
  5. Willing and able to follow the requirements of the protocol
  6. Subjects who had a chronic venous leg ulcer (i.e. CEAP classification of C6 1) greater than 2 cm2 and less than 10 cm in maximum diameter,
  7. ABPI of 0.8-1.2 inclusive
Exclusion Criteria
  1. Wound infection either acute or chronic
  2. History of significant haematological disorders or DVT with the preceding six months
  3. Pregnant
  4. Pacemakers or implantable defibrillators
  5. Use of any other neuro-modulation device
  6. Current use of TENS in pelvic region, back or legs
  7. Use of investigational drug or device within the past 4 weeks that may interfere with this study
  8. Recent surgery that may affect the study (such as abdominopelvic, or lower limb) in the opinion of the investigator.
  9. Recent trauma to the lower limbs
  10. Size of leg incompatible with the gekoTM plus R-2 device
  11. Obesity (BMI > 34)
  12. Any medication deemed to be significant by the Investigator
  13. Subjects who had an index venous leg ulcer greater in maximum diameter than 10cm in any one dimension, or less than 2cm.
  14. Diabetes
  15. Clinical evidence of peripheral arterial disease (i.e signs or symptoms, in the opinion of the researcher)

Study & Design

Study Type
INTERVENTIONAL
Study Design
SINGLE_GROUP
Arm && Interventions
GroupInterventionDescription
geko plus R-2geko plus R-2neuromuscular electrostimulation
Primary Outcome Measures
NameTimeMethod
The lower limb blood flow between gekoTM plus R-2 and IPC devices in VLU patients will be assessed.3 months

Duplex ultrasound of the femoral vein and artery will be performed with bilateral recording of blood flow velocity. After 10 minutes activation of either geko™ or IPC and after the 10 minutes the devices will swapped over and measurements performed. All measurements to be carried out in triplicate.

Secondary Outcome Measures
NameTimeMethod
Adverse events assessments3 months

Patients will be monitored for adverse events throughout the duration of the study. Adverse events may be spontaneously reported by the subject, observed by the study personnel.

Serious Adverse Events will be reported to the Sponsor, the National Research Ethics Service (NRES) recognised Research Ethics Committee.