To compare the success rate of old technique trabeculectomy versus new technique implantation of drainage device in the anterior chamber of the eye in glaucoma patients.
- Conditions
- Other glaucoma,
- Registration Number
- CTRI/2023/08/056128
- Lead Sponsor
- Jawaharlal nehru medical college SAWANGI
- Brief Summary
Glaucoma is becoming a more common causeof blindness as the world’s population ages. Glaucoma, the second largest causeof blindness worldwide, accounts approximately 15% of all blindness. It posesan even bigger public health concern than cataracts, however, because theblindness it produces is irreversible.This study aims to compare the clinicaloutcomes of traditional trabeculectomy and glaucoma drainage device. This is a hospital-basedstudy of 30 patients in which we compare clinical results after conventionaltrabeculectomy and implantation of a glaucoma drainage device. Intraocularpressure measure by Applanation tonometer and best corrected visual acuity testingwill be performed in all patients. The data will be compared and statisticalanalysis will be done. Patients with Glaucoma drainage implantswill have better IOP control.
- Detailed Description
Not available
Recruitment & Eligibility
- Status
- Open to Recruitment
- Sex
- All
- Target Recruitment
- 30
- 1)Patients with uncontrolled primary glaucoma.
- 2)Patients who will be diagnosed with secondary glaucoma.
- 3)Patients who will be diagnosed with refractory glaucoma.
- 4)Patients are consenting to study/ giving valid consent.
- 1)Patients with any ocular infection.
- 2)Patients having corneal decompensation.
- 4)Patients who did not successfully complete a minimum 1-year follow-up period were not included in this study.
Study & Design
- Study Type
- Interventional
- Study Design
- Not specified
- Primary Outcome Measures
Name Time Method 1)Visual acuity testing by Snellen’s chart- 2 YEARS It is used to assess distant visual acuity. The patient is seated 6m away from Snellens chart & is instructed to read the chart with both eyes, one after the other. When the patient can read up to a 6 m line, his visual acuity is reported as 6/6, & depending on the smallest line that the patient can read from a 6 m distance, his vision is recorded as 6/9, 6/12, 6/18, 6/24, 6/36, & 6/60. 2 YEARS 2)Intra Ocular Pressure measurement by applanation tonometry- 2 YEARS The Goldmann Applanation Tonometer is commonly recognised as the gold standard in intraocular pressure (IOP) measurement. A topical anaesthetic is instilled into the conjunctival sac, followed by a fluorescein stain. The cobalt blue filter reveals a pattern of two green semicircular mires, with the inner borders of semicircles aligned. The IOP is calculated by multiplying the dial value by ten in mmhg. 2 YEARS
- Secondary Outcome Measures
Name Time Method 1)Moorfields bleb grading- The bleb is assessed & characterized with respect to-
Trial Locations
- Locations (1)
Acharya vinoba bhave rural hospital
🇮🇳Wardha, MAHARASHTRA, India
Acharya vinoba bhave rural hospital🇮🇳Wardha, MAHARASHTRA, IndiaDR AYUSHI TAYALPrincipal investigator8770457121ayushi31tayal@gmail.com