MedPath

Visual Performance of an Extended Depth of Focus IOL in an Emmetropic or Monovision Modality

Not Applicable
Recruiting
Conditions
Cataract
Interventions
Device: Emmetropic modality
Device: Monovision modality
Registration Number
NCT06624826
Lead Sponsor
Prim. Prof. Dr. Oliver Findl, MBA
Brief Summary

Comparison of the visual performance of a refractive extended depth of focus intraocular lens in an emmetropic or monovision modality

Detailed Description

With an expanding market of different types of intraocular lenses (IOL), spectacle independence is a rising aim in modern cataract surgery. The procedure has in many cases changed from a vision restoring to a presbyopia correcting approach. Although bilateral monofocal IOL implantation, aiming for emmetropia, leads to high levels of patient satisfaction for distance vision, spectacle dependence for reading and intermediate vision tasks is the usual result.

The option commonly used to achieve spectacle independence at intermediate distance (e.g., PC work) is the implantation of enhanced depth of focus (EDOF) IOLs. These IOLs have an extended far focus area which reaches to the intermediate distance, providing high-quality vision over a continuous range of focus, rather than distinct foci with blur in between. In the last years several technologies for EDOF IOLs appeared on the market. The spectrum ranges from small aperture design, bioanalogic design, to diffractive and non-diffractive optics. The disadvantage compared to monofocal lenses in all the technologies mentioned is the potentially worse distance vision and contrast sensitivity as well as dysphotopsia.

A new refractive EDOF lens segment with an extended depth of vision was introduced which promises an increased range of functional vision and less dysphotopsias compared to diffractive EDOF lenses. These non-diffractive IOLs are believed to be a presbyopia correcting alternative for people with existing corneal or macula pathologies, which would preclude them from receiving premium lenses because of the loss of light in the diffractive process. To increase spectacle independence for these patients, IOLs may be used in a monovision modality, with an offset of up to 1.5dpt. This method showed good results in the literature so far for monofocal and multifocal intraocular lenses.

Aim of the study is to compare a new non-diffractive EDOF-IOL, namely the PureSee, set for emmetropia or monovision.

120 eyes of 60 patients will be included into this study. Patients will be either randomized in the emmetropia or the monovision group

Follow-up visits will be 1 week after each surgery and 3 months post-surgically. During these visits, the clinical variables to be assessed will be visual acuity, stereopsis, contrast sensitivity, and binocular defocus curves.

Recruitment & Eligibility

Status
RECRUITING
Sex
All
Target Recruitment
60
Inclusion Criteria
  • Age-related bilateral cataract
  • Age 21 or older
  • Visual acuity > 0.05
  • Axial length: 21.00-27.00mm
  • Normal findings in the medical history and physical examination unless the investigator considers an abnormality to be clinically relevant
  • Written informed consent prior to surgery
Exclusion Criteria
  • Active ocular disease (e.g chronic uveitis, diabetic retinopathy, chronic glaucoma not responsive to medication, corneal dystrophies, etc.) precluding good post-operative visual acuity
  • Relevant other ophthalmic diseases such as pseudoexfoliation syndrome (PEX)
  • Irregular astigmatism on corneal tomography
  • Pronounced dry eye disease
  • Previous ocular surgery or trauma
  • Persons who are pregnant or nursing (pregnancy test will be taken in women of reproductive age)

Study & Design

Study Type
INTERVENTIONAL
Study Design
PARALLEL
Arm && Interventions
GroupInterventionDescription
PureSee EmmetropiaEmmetropic modalityPatient will receive the PureSee IOL with an emmetropic modality
PureSee MonovisionMonovision modalityPatient will receive the PureSee IOL in a monovision modality
Primary Outcome Measures
NameTimeMethod
Corrected and uncorrected binocular visual acuity for near distance12 months

Corrected and uncorrected binocular visual acuity for near distance will be assessed at 40 cm using ETDRS charts

Secondary Outcome Measures
NameTimeMethod
Corrected and uncorrected binocular visual acuity for distance12 months

Corrected and uncorrected binocular visual acuity for distance will be assessed at 4 m using ETDRS charts

Corrected and uncorrected binocular visual acuity for intermediate distance12 months

Corrected and uncorrected binocular visual acuity for intermediate distance will be assessed at 66 cm using ETDRS charts

Contrast sensitivity12 months

Contrast sensitivity will be tested using the Optec Vision tester under mesopic and photopic conditions with and without an additional glare source

Subjective quality of vision12 months

Subjective quality of vision will be assessed using a questionnaire

Trial Locations

Locations (1)

Vienna Institute for Research in Ocular Surgery

🇦🇹

Vienna, Austria