MedPath

Pulsed Field Ablation vs Cryoablation In Paroxysmal Atrial Fibrillation

Not Applicable
Not yet recruiting
Conditions
Atrial Fibrillation Paroxysmal
Interventions
Device: Pulse field ablation
Device: Cryoballoon pulmonary vein isolation
Registration Number
NCT05940597
Lead Sponsor
University Hospital, Grenoble
Brief Summary

Cryoballoon pulmonary vein isolation (PVI) has emerged as an alternative to radiofrequency in the treatment of drug-resistant atrial fibrillation (AF). (1) Cryoablation offers potential advantages over radiofrequency, including shorter procedure times, decreased fluoroscopy time, shorter hospital length of stay, and different rates and types of complications. (2) The efficacy over a mean follow-up of one year with cryoablation for AF is comparable to that of radiofrequency ablation in a prospective randomized trial, with a lower major complication rate (3, 4). In recent years, AF cryoablation has established itself as a real alternative to RF ablation, to the point that this ablative source is chosen in one out of five European patients undergoing PV isolation. 70-80% of patients maintain sinus rhythm after a first procedure, showing an efficacy rate equivalent to ablation by RF. It is also comparable to RF when it comes to safety. Phrenic nerve palsy remains the major concern of cryoablation, accounting for 40% of periprocedural complications. A reduction in total procedure time and less dependence on the operator's experience make cryoablation an attractive choice for centres starting an AF ablation program. In conclusion, we do not yet have definitive data to affirm the superiority of one energy source over the other. Generally the choice depends on the availability of the centre and on the experience of the operator.

Pulse field ablation (PFA): Vivek Y. Reddy demonstrates that in patients with paroxysmal atrial fibrillation, PFA rapidly and efficiently isolates PVs with a degree of tissue selectivity and a safety profile(1).PFA can achieve a high degree of durable PV isolation with a comparable efficiency than another techniques (RF or CRYO) at one year follow-up (2) Cryoablation has been a recognised technique for the ablation of atrial fibrillation for many years, with many studies comparing the technique to radiofrequency ablation with equal results. Studies are underway to compare radiofrequency AF ablation versus PFA (BEAT-AF study). A randomized study to compare two methods of cryoablation versus PFA will be necessary to validate the non-inferiority of the technique.

Detailed Description

Not available

Recruitment & Eligibility

Status
NOT_YET_RECRUITING
Sex
All
Target Recruitment
350
Inclusion Criteria
  • The patient is of legal age to participate in the study (age >18 years)
  • The patient is eligible for ablation of paroxysmal atrial fibrillation
  • The patient or legal representative is able to understand and willing to provide written informed consent to participate in the trial
  • The patient is able and willing to return for required follow-up visits and examinations
Exclusion Criteria
  • Previous AF ablation
  • Persistent and permanent AF
  • The patient is contraindicated or allergic to oral anticoagulation
  • The patient or legal representative is enable to understand and willing to provide written informed consent to participate in the trial
  • The patient is enable and willing to return for required follow-up visits and examinations
  • Pregnant or nursing patient
  • Patient in exclusion period of another interventional study,
  • Patient under administrative or judicial supervision

Study & Design

Study Type
INTERVENTIONAL
Study Design
PARALLEL
Arm && Interventions
GroupInterventionDescription
PFA armPulse field ablationMarket approved PFA ablation system (Farapulse - Boston Scientific system).
Cryoablation armCryoballoon pulmonary vein isolationMarket approved cryoablation system
Primary Outcome Measures
NameTimeMethod
proportion of subjects experiencing one-year single-procedure clinical success12 months

successful index of AF ablation, absence of atrial arrhythmia recurrence on any type of recording (30 sec by TTM (event monitor), holters, 12-lead ECGs, rhythm strip or other diagnostic ECG documentation), absence of use of class I or III AAD.

Secondary Outcome Measures
NameTimeMethod
Proportion of patients with death12 months

Death from any causes

Total time of fluoroscopyduring the procedure

Total time of fluoroscopy in minutes

Proportion of patients with acute complication related to the procedureduring the procedure or one day after

tamponade, stroke, myocardial infarction, other

Health-related quality of life6 and 12 months

SF-12 questionnaire.

Total procedure durationduring the procedure

Procedure duration in minutes

Improvement in AF-specific quality of life6 and 12 months

AFEQT questionnaire

Proportion of patients with first hospitalization for cardiovascular causes.12 months

First hospitalization for cardiovascular causes

Proportion of patients with embolic events from arrhythmia12 months

Stroke

Long term complications related to the procedure12 months

phrenic palsy, pulmonary vein stenosis, pericarditis, other

Recurrence of atrial fibrillation12 months

Absence of atrial arrhythmia recurrence on any type of recording (30 sec by TTM (event monitor), holters, 12-lead ECGs, rhythm strip or other diagnostic ECG documentation), absence of use of class I or III AAD

© Copyright 2025. All Rights Reserved by MedPath