Failed Epidural Anesthesia During Labor: Evaluation of Risk Factors and Impact on Labor ,Maternal and Fetal Outcomes
试验速览
- 阶段
- 不适用
- 入组人数
- 500
- 试验地点
- 1
- 主要终点
- duration of first stage of labor
研究概览
简要总结
Women requesting epidural analgesia will receive a bolus of intravenous infusion of lactated Ringer's solution before initiation of the procedure. An 18-gauge Tuohy needle and closed-tip clear catheter with three lateral orifices (Portex, Smith Medical, Hythe, UK) were used in the sitting or lateral position, with a loss-of-resistance to air technique. Epidural catheters will be inserted 5-6 cm inside the epidural space. A test dose of 2 ml of lidocaine 2% iss initiated followed by a loading dose of 10 ml of bupivacaine 0.25%. Analgesia is established and maintained throughout labor and delivery using 0.125% bupivacaine with fentanyl 2 μg/ml with patient-controlled epidural analgesia by means of a continuous epidural infusion (8 ml/h basal rate) and patient-controlled boluses (3 ml each) with 20-minlock-out intervals, continued at the same bolus dose until delivery.
Pain was evaluated using a 0-10 cm visual analogue scale (VAS) before, 15 and 30 min after the loading dose followed by hourly assessment until delivery. VAS score assessment was based specifically on abdominal or back pain resulting from contractions
详细描述
Women requesting epidural analgesia will receive a bolus of intravenous infusion of lactated Ringer's solution before initiation of the procedure. An 18-gauge Tuohy needle and closed-tip clear catheter with three lateral orifices (Portex, Smith Medical, Hythe, UK) were used in the sitting or lateral position, with a loss-of-resistance to air technique. Epidural catheters will be inserted 5-6 cm inside the epidural space. A test dose of 2 ml of lidocaine 2% iss initiated followed by a loading dose of 10 ml of bupivacaine 0.25%. Analgesia is established and maintained throughout labor and delivery using 0.125% bupivacaine with fentanyl 2 μg/ml with patient-controlled epidural analgesia by means of a continuous epidural infusion (8 ml/h basal rate) and patient-controlled boluses (3 ml each) with 20-minlock-out intervals, continued at the same bolus dose until delivery.
Pain was evaluated using a 0-10 cm visual analogue scale (VAS) before, 15 and 30 min after the loading dose followed by hourly assessment until delivery. VAS score assessment was based specifically on abdominal or back pain resulting from contractions. Failed epidural is defined as VAS score ≥5, 30 min after a loading dose, given after the last attempt. Women who had a repeated attempt due to VAS ≥5 at 30 min or dural puncture or required repositioning of the catheter, resulting in subsequent pain relief expressed as VAS score <5 were not considered to have a Failed epidural. VAS score is assessed by obstetrician and not the anesthesiologist who performed the block. Furthermore, intrapartum vaginal examinations to assess cervical dilatation and fetal head station were also performed by experienced obstetrician.
As part of the study, the women's satisfaction was assessed the morning following delivery using a 1-5 satisfaction scale, where score 1 corresponded to very unsatisfied and score 5 corresponded to very satisfied. Before satisfaction assessment, all women who agreed to participate signed an informed consent and then relevant data was collected from the participants' medical charts.
研究设计
- 研究类型
- Interventional
- 分配方式
- Non Randomized
- 干预模型
- Parallel
- 主要目的
- Treatment
- 盲法
- None
入排标准
- 年龄范围
- 19 Years 至 40 Years(Adult)
- 性别
- Female
- 接受健康志愿者
- 否
入选标准
- •≥34 weeks of gestation
- •receiving epidural analgesia during labor,
排除标准
- •Women who had a planned cesarean delivery,
- •intrauterine fetal death
- •non-vertex presentation
- •delivered at less than 30 min after epidural insertion
- •contraindication for epidural analgesia (i.e., thrombocytopenia <100,000 cells/μl, ongoing thromboprophylaxis with low-molecular-weight or unfractionated heparin, and bacteremia or infection at the needle-puncture site)
研究组 & 干预措施
Successful epidural anaesthesia
It is defined as VAS score <5, 30 min after a loading dose, given after the last attempt.
干预措施: epidural anaesthesia (Procedure)
Failed epidural anaesthesia
It is defined as VAS score ≥5, 30 min after a loading dose, given after the last attempt.
干预措施: epidural anaesthesia (Procedure)
结局指标
主要结局
duration of first stage of labor
时间窗: from start of cervical dilatation till full cervical dilatation
effect of success and failure of epidural on duration of first stage of labor (..before, 15 and 30 min after the loading dose followed by hourly assessment until delivery..)
次要结局
未报告次要终点
