跳至主要内容
临床试验/NCT04163471
NCT04163471已完成不适用

VasoStat vs. TR Band for Hemostasis Following Transradial Catheterization Without Prior Radial Access

Forge Medical1 个研究点 分布在 1 个国家目标入组 40 人开始时间: 2018年6月4日最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
发起方
入组人数
40
试验地点
1
主要终点
Comparison of impact of two radial artery compression devices on hand perfusion measurements

研究概览

简要总结

VasoStat vs. TR Band compression for Radial Artery Hemostasis Following Transradial Catheterization Without Prior Radial Artery Access

详细描述

Patients will be enrolled if they are scheduled to undergo a coronary or peripheral catheterization procedure involving the placement of a sheath (plastic tube) in the radial artery near the participants wrist. The purpose of this research is to compare two devices which make bleeding stop after the participants procedure is finished and the plastic tube is removed from the radial artery in the wrist. The two devices are called the VasoStat and the TR Band. Both of these devices are called hemostasis devices, which means they stop bleeding (hemostasis). Both devices are approved by the Food and Drug Administration (FDA) and are used throughout hospitals in the United States. The investigators will compare blood flow to the hand, and survey patients as to how comfortable these devices are, while they are being used to stop bleeding after the catheterization procedure.

Patients will be randomized to one device or the other as part of the study.

The investigators will noninvasively measure the blood flow to the hand by placing a soft plastic probe on the tip of the thumb called a plethysmography probe. This measurement only takes a few seconds and is painless. The investigators will measure before, after application and after removal & before patients are discharged. Thirty days later, patients will return for another measurement and to examine the radial artery with an ultrasound probe.

40 patients will be enrolled. Statistical analysis: Based on prior studies, The investigators will assume that the VasoStat produces a 30% reduction in hand perfusion during normal clinical use. The investigators assume the TR Band produces a 70% reduction in hand perfusion during normal clinical use. Using a two-sample test of proportions, with a Type I error of 5%, a power of 80%, and an anticipated drop-out rate of 10%, The investigators will need to enroll 40 patients (20 patients in each arm of the study) (StatMate 2.0, GraphPad Software, San Diego, CA)

研究设计

研究类型
Observational
观察模型
Case Only
时间视角
Prospective

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • no prior radial access

排除标准

  • Patients receiving concurrent investigational medications
  • Cellulitis overlying radial artery
  • Oral anticoagulation
  • Patients receiving glycoprotein IIb/IIIa inhibitors
  • Prisoners
  • Institutionalized individuals
  • Allergy to medical adhesive
  • Radial sheath > 6 French (ID)

结局指标

主要结局

Comparison of impact of two radial artery compression devices on hand perfusion measurements

时间窗: Perfusion index measurements day 1: before radial artery puncture, during wrist compression, after removal of compression device. Final perfusion index at 30-day followup appointment.

Changes in Hand perfusion will be quantified using a noninvasive pulse oximetry technique and a previously validated metric known as the Perfusion Index, which is the ratio of the pulsatile blood flow to the nonpulsatile or static blood in peripheral tissue. The Perfusion Index represents a noninvasive measure of hand perfusion that can be continuously and noninvasively obtained from a specialized pulse oximeter.

次要结局

  • Comparison of impact of two radial artery compression devices on hand perfusion prior to and during ulnar artery compression(Perfusion index measurements on day 1 with ulnar compression: will include before radial artery puncture, and during wrist compression after radial sheath removal.)
  • Hand perfusion and radial artery patency after one month(30 day follow-up after use of mechanical wrist compression following transradial access for arterial catheterization procedures)
  • Patient satisfaction during use of wrist compression device(During application of radial artery mechanical compression)

研究者

发起方
Forge Medical
申办方类型
Industry
责任方
Sponsor

研究点 (1)

Loading locations...

相似试验