RHythmia mAPping and Signal acquisitiOn for Data analYsis (RHAPSODY)
- Conditions
- Cardiac Arrythmias
- Interventions
- Device: Rhythmia Mapping System
- Registration Number
- NCT03053141
- Lead Sponsor
- Boston Scientific Corporation
- Brief Summary
The objective of the RHAPSODY study is to evaluate the performance of new software features in subjects undergoing standard of care catheter-based endocardial mapping for atrial or ventricular tachyarrhythmias using a commercial Rhythmia Mapping System. Results from this study will be used to guide development and refinement of new software features that may be implemented in future commercial software releases.
- Detailed Description
The Rhythmia Mapping System is designed for electroanatomical mapping in catheter ablation procedures by optimizing the need for speed and accuracy. The system is able to simultaneously acquire data from multiple electrodes. In addition, based on user-defined criteria, the system is able to efficiently acquire data over multiple cardiac beats. When used in conjunction with the Rhythmia Mapping Catheter, the system is able to acquire up to hundreds of points per minute leading to fast and detailed map creation.
Since its market release, physicians and users have gained experience with the Boston Scientific Rhythmia Mapping System in the human clinical setting. Improvements to the first generation system are in development and include new and improved software features and mapping algorithms to enhance the clinical operation. These new and improved software features and algorithms require leveraging clinical use data as part of the development and iteration process.
This study will evaluate the performance of potential next-generation software features in a low-risk clinical environment by streaming raw signals from a commercial Rhythmia Workstation during standard of care cardiac mapping and ablation treatments for tachyarrhythmias, specifically atrial fibrillation, atrial tachycardias, and ventricular tachycardia. The data will be evaluated on a parallel investigational Rhythmia Workstation using prototype software features. These next-generation software features and algorithms will not be available to the physician during the case and will therefore have no diagnostic or therapeutic impact on the clinical case.
Recruitment & Eligibility
- Status
- RECRUITING
- Sex
- All
- Target Recruitment
- 100
- Age 18 or above, or above legal age and willing and capable of giving informed consent specific to national law
- Scheduled for standard of care catheter-based endocardial mapping for atrial or ventricular tachyarrhythmias using a commercial Rhythmia Mapping System.
- Prothrombotic or bleeding tendency due to coagulopathy or blood dyscrasia
- Inability to tolerate heparin therapy (e.g. heparin induced thrombocytopenia, allergy, etc.)
- Prosthetic or stenotic valves in the chamber where the intended mapping will occur, or in the path of the catheter access route
- Active systemic infection or sepsis
- Hemodynamic instability or shock at baseline precluding ablation in the assessment of the investigator.
- Presence of intracardiac thrombus, tumor, or other abnormality which precludes catheter introduction
- Women who are pregnant or lactating
- Cardiac surgery within the past 90 days
- Acute myocardial infarction within 3 months
- Stable/unstable angina or ongoing myocardial ischemia
- Subjects with an active heart failure decompensation
- Long QT Syndrome, Brugada Syndrome, or Torsade de Pointes
- Congenital heart disease with or without corrective surgery that would complicate a mapping procedure
- Subjects having untreatable allergy to contrast media
- Vascular pathology or tortuosity precluding standard vascular access techniques
- Subjects who are currently enrolled in another investigational study or registry that would directly interfere with the current study, except when the patient is participating in a mandatory governmental registry, or a purely observational registry with no associated treatments. Each instance should be brought to the attention of the sponsor to determine eligibility.
Study & Design
- Study Type
- OBSERVATIONAL
- Study Design
- Not specified
- Arm && Interventions
Group Intervention Description All Subjects Rhythmia Mapping System All subjects are included in this cohort and are treated with the Rhythmia Mapping System
- Primary Outcome Measures
Name Time Method Physician Feedback on Software Performance 1 day- Procedure Physician Feedback on Software Performance
- Secondary Outcome Measures
Name Time Method
Trial Locations
- Locations (7)
University of Alabama at Birmingham
🇺🇸Birmingham, Alabama, United States
Fondazione Centro San Raffaele
🇮🇹Milan, MI, Italy
St. Lukes Idaho Cardiology Associates
🇺🇸Boise, Idaho, United States
Lahey Clinic, Inc.
🇺🇸Burlington, Massachusetts, United States
Valley Hospital
🇺🇸Ridgewood, New Jersey, United States
Centre Hospitalier Princesse Grace
🇲🇨Monaco, Monaco
Catholic Medical Center
🇺🇸Manchester, New Hampshire, United States