跳至主要内容
临床试验/NCT04427007
NCT04427007已完成不适用

Moisture Management Liner Effectiveness Study

Liberating Technologies, Inc.1 个研究点 分布在 1 个国家目标入组 2 人开始时间: 2020年7月1日最近更新:
适应症
干预措施

试验速览

阶段
不适用
状态
已完成
入组人数
2
试验地点
1
主要终点
Residual Limb Temperature

研究概览

简要总结

The comfort and fit of the residual limb within a prosthetic socket are of primary concern for many amputees. The residual limb is typically covered by non-breathable and non- thermally conductive materials that can create a warm and ultimately moist environment.

The investigators have developed a silicone liner approach to remove sweat from the skin and out of the socket and to passively conduct heat from the skin using thermally conductive elastomers. This liner has been developed to work alongside a thermo-electric cooling (TEC)-based module called the Intrasocket Cooling Element (ICE) developed in a parallel project by Vivonics, Inc. and Liberating Technologies, Inc. The ICE device can be embedded into the prosthesis in order to cool the residual limb. A technology that can provide thermal control while retaining adequate suspension, weight, and other prosthetic characteristics would benefit many prosthesis wearers.

详细描述

The comfort and fit of the residual limb within a prosthetic socket are of primary concern for many amputees. The residual limb is typically covered by non-breathable and non- thermally conductive materials that can create a warm and ultimately moist environment. These layers consist of a prosthetic liner that rolls onto the limb and traps heat and occasional extra prosthetic socks. Studies found increases in socket temperature after the prosthesis was donned. Temperatures were found to remain elevated long after activity cessation and even a rest period of double the duration of the preceding activity period is insufficient to return the limb to its initial temperature. A small amount of activity can cause the socket temperature to elevate and remain at an uncomfortable level for an extended period of time, which can lead to decreased wear times. In summary, an uncomfortable socket/residual limb interface decreases prosthesis use among amputees who want to remain active in their lives.

To address this, the investigators have developed a silicone liner approach to remove sweat from the skin and out of the socket and to passively conduct heat from the skin using thermally conductive elastomers. This liner has been developed to work alongside a thermo-electric cooling (TEC)-based module called the Intrasocket Cooling Element (ICE) developed in a parallel project by Vivonics, Inc. and Liberating Technologies, Inc. The ICE device can be embedded into the prosthesis in order to cool the residual limb. A technology that can provide thermal control while retaining adequate suspension, weight, and other prosthetic characteristics would benefit many prosthesis wearers.

This study will focus on investigating the efficacy of this novel moisture and thermal management (experimental) liner.

The rationale for this study is to determine how well the new technology can regulate the residual limb temperature, reduce the moisture generation, and remove excess moisture in a controlled laboratory environment.

The objective of this study is to measure the effects experimental techniques of moisture and thermal management has on moisture and temperature in the socket. Moisture and thermal management of the residual limb inside the prosthetic socket could result in greater comfort while wearing the prosthesis, and ultimately could result in greater function and better quality of life (QoL). Other measures that may be collected are exploratory.

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Crossover
主要目的
Other
盲法
None

入排标准

年龄范围
18 Years 至 89 Years(Adult, Older Adult)
性别
All
接受健康志愿者
是

入选标准

  • •Lower limb amputee
  • •Be willing and able to complete the tasks outlined
  • •Are at least 6 months on a definitive prosthesis
  • •Fits within an experimental liner
  • •Can understand English in order to be properly consented and provide their feedback to the study personnel

排除标准

  • •The risks to pregnant women and fetuses are unknown and therefore pregnant women should not participate in the study
  • •Other unforeseen disqualifying criteria (such as specific cognitive issues, etc.)

研究组 & 干预措施

Experimental Prosthetic Liner

Experimental

Participants will test the experimental prosthetic liner by walking on a treadmill while wearing the liner.

干预措施: Moisture Management Liner (Device)

Control Prosthetic Liner

Other

Participants will test the control (participant's usual) liner by walking on a treadmill while wearing the liner.

干预措施: Control Liner (Device)

结局指标

主要结局

Residual Limb Temperature

时间窗: 2 hours

Changes in residual limb temperature during walking/resting measured with temperature sensors placed on the limb. Positive values signify a raise in temperature and negative values signify a drop in temperature between the start of walking to the end of walking.

次要结局

未报告次要终点

研究者

申办方类型
Industry
责任方
Principal Investigator
主要研究者

Todd Farrell

Director of Research

Liberating Technologies, Inc.

研究点 (1)

Loading locations...

相似试验